background image

23

1. General

Dear customer,

we are pleased that you have decided to buy

a KESSEL product.

The entire plant was subjected to a stringent

quality control before it left our factory. Ne-

vertheless,  please  check  immediately

whether the plant has been delivered to you

complete and undamaged. In case of any

transport  damage,  please  refer  to  the  in-

structions in the chapter “Warranty” in this

manual.

These installation, operating and mainten-

ance instructions contain important informa-

tion that has to be observed during assem-

bly, operation, maintenance and repair. Prior

to carrying out any work on the plant, the

operator and the responsible technical per-

sonnel must carefully read and heed these

instructions.

KESSEL AG

Area of application:

The switch unit Aqatronic S is used to control

the KESSEL rainwater pumping systems Aqa-

bull and Aqadive.

If the water level in the cistern falls below a cer-

tain adjustable level, automatic drinking water

feeding  of  the  rainwater  pumping  system  is

triggered

Drinking water feeding can also be activated

manually.  This  is  useful  when  functional

tests or work are being carried out on the

plant.

A floating switch is included in the scope of

supply. Optionally, a second floating switch

(accessories) can be used for safety switch-

off.

Summary of Contents for Aqatronic S 85 025

Page 1: ...F r Magnet oder 3 Wege Umschalt Ventil Zus tzliche Sicherheitsabschaltung m glich Hohe Betriebssicherheit Bundesweites Servicenetz Art Nr 85 025 Produktvorteile Name Unterschrift Datum Ort Stempel Fac...

Page 2: ...ull Seite 8 4 3 Anlagenbeschreibung Aqadive Seite 9 5 Montage 5 1 Montage Schaltger t Seite 10 5 2 Montage Schwimmerschalter Seite 11 6 Elektroanschlu Seite 12 7 Bedienung Funktion 7 1 Inbetriebnahme...

Page 3: ...Repara tur zu beachten sind Vor allen Arbeiten an der Anlage m ssen der Betreiber sowie das zust ndige Fachpersonal diese Anleitung sorgf ltig lesen und befolgen KESSEL AG Einsatzbereich Das Schaltger...

Page 4: ...iner Ge samtanlage dar Beachten Sie deshalb auch die Bedienungsanleitungen der Gesamtan lage und der einzelnen Komponenten Bei jeder Montage Wartung Inspektion und Re paratur an einer der Komponenten...

Page 5: ...wimmer Stellung oben Kontakt ge ffnet Schwimmer Stellung unten Kontakt geschlossen Kabelmanteldurchmesser 9 mm Kabelmantelmaterial H07RN F 3G1 VDE Kabell nge 20 m Ver nderungen am Schwimmerschalter Ka...

Page 6: ...Anschluss Trinkwassernachspeisung Anschluss Schwimmerschalter 1 Anschluss Schwimmerschalter 2 Sicherheitsabschaltung optional Kurzbedienungsanleitung LED gr n Anzeige Betrieb LED orange Anzeige Trinkw...

Page 7: ...r t das ber bzw Unterschreiten des eingestellten Wasserstands in der Re genwasserzisterne Schwimmerschalter 2 nicht im Lieferumfang enthalten Bei der KESSEL Regenwasserpumpanla ge Aqadive kann optiona...

Page 8: ...fberuhigung berlaufsiphon schwimmende Entnahme Trinkwassernachspeisebeh lter Schwimmerventil Absperrventil Trinkwassernachspeisung Not berlauf mit Geruchverschlu Pumpe mit Druckschaltautomat 3 Wege Um...

Page 9: ...lung Zisterne Einlaufberuhigung berlaufsiphon schwimmende Entnahme Pumpe Druckschaltautomat Absperrventil Betriebswassernetz Trinkwassernachspeisung Magnetventil Trinkwassernachspeisung Absperrventil...

Page 10: ...as Schaltger t an geeigneter Stelle z B in Augenh he an der Wand montiert Sp ter mit max 1 Nm wieder verschrauben selbstschneidende Schrauben Den Schalt kasten wie abgebildet mit den 4 Holzschrau ben...

Page 11: ...ragen um ein Ansaugen aus der Sedi mentschicht der Zisterne zu verhindern Bei Verwendung eines zweiten muss derAb stand zum unteren Schwimmerschalter so gro gew hlt werden da sich beide nicht ber hren...

Page 12: ...iese zur Abdichtung des Geh uses dient Die Mutter und den Korb f r die Zugentla stung auf die Leitung aufstecken siehe Abb b die Leitung in das Schaltger t ein f hren und entsprechend Anschlu plan an...

Page 13: ...13 6 Elektroanschluss Anschluss Magnetventil Anschluss 3 Wege Umschaltventil...

Page 14: ...Wasserstand liegt ber dem Niveau 1 l uft die Anlage im Regen wasserbetrieb Im Bedarfsfall wird Betriebs wasser aus der Zisterne zum Verbraucher gef rdert Sinkt der Wasserstand unter das Niveau 1 wird...

Page 15: ...in der Zister ne das Niveau 4 so wird eine evtl bestehen de automatische oder manuelle Trinkwas sernachspeisung abgeschaltet und verriegelt auch manuell nicht einschaltbar Die Trinkwassernachspeisung...

Page 16: ...den Herstel ler vorgenommen werden Das Schaltger t bedarf keiner Wartung Der Schwimmerschalter ist in regelm igen Abst nden auf Verschmutzung undAusrich tung zu kontrollieren Dabei ist auf eine scho...

Page 17: ...die Gew hrleistungsfrist neu zu laufen jedoch nur im Umfang der Neu lieferung Es wird nur f r neu hergestellte Sachen eine Gew hrleistung bernommen Die Gew hrleistungsfrist betr gt 24 Monate ab Ausli...

Page 18: ...inie des Rates zur Angleichung der Rechtsvorschriften der Mitgliedstaaten betreffend elektrische Betriebsmittel zur Verwendung innerhalb bestimmter Spannungsgrenzen 73 23 EWG festgelegt sind Zur Beurt...

Page 19: ...Telefon Telefax Ausf hrende Elektrofirma Adresse Telefon Telefax Abnahmeberechtigter Adresse Telefon Telefax bergabeperson Sonstige Anmerkungen Die Inbetriebnahme laut EBA und Einweisung wurde im Bei...

Page 20: ...20 bergabeprotokoll I I I I I I...

Page 21: ...c or manual drinking water feeding can be selected For solenoid or 3 way switch over valve Additional safety switch off possible High operational security Nationwide service network Art 85 025 Product...

Page 22: ...System description Aqadive Page 29 5 Installation 5 1 Installation of the switch unit Page 30 5 2 Installation of the floating switches Page 31 6 Electrical Connection Page 32 7 Operation 7 1 Initial...

Page 23: ...n maintenance and repair Prior to carrying out any work on the plant the operator and the responsible technical per sonnel must carefully read and heed these instructions KESSEL AG Area of application...

Page 24: ...eeded The system represents one component in a whole plant Please therefore also heed the operating instructions for plant as a whole and the individual components During as sembly maintenance service...

Page 25: ...k contact Float position top Contact broken Float position bottom Contact made Cable sheath diameter 9 mm Cable sheath material H07RN F 3G1 VDE Cable length 20 m Changes to the floating switch cable o...

Page 26: ...e 1 m Connection drinking water feeding Connection floating switch 1 Connection floating switch 2 optional safety switch off Brief operating instructions LED green for operation LED orange for drinkin...

Page 27: ...ter level in the rain water cistern is exceeded or not reached Floating switch 2 not included in the scope of supply In the case of the KESSEL rainwater pum ping system Aqadive a second floating switc...

Page 28: ...Overflow siphon Floating removal Drinking water feeding tank Floating switch Shut off valve for drinking water feeding Emergency overflow with odour trap Pump with automatic pressure switch 3 way swi...

Page 29: ...ing Cistern Feed slowdown Overflow siphon Floating removal Pump Automatic pressure switch Shut off valve service water network Drinking water feeding Solenoid drinking water feeding Shut off valve dri...

Page 30: ...etely installed in the system If used separately the switch unit is installed in a sui table spot e g at eye level on the wall Screw in place self cutting screws later using max 1 Nm Attach the switch...

Page 31: ...15 20 cm in order to prevent se diment being suctioned in from the bottom of the cistern When a second floating switch is used the di stance to the lower floating switch must be big enough to prevent...

Page 32: ...al must not be pierced since they are required to seal the housing Insert the nut and the cage for strain relief onto the cable see Fig b insert the cable into the switch unit and connect up accor din...

Page 33: ...33 6 Electrical Connection Anschluss Magnetventil Anschluss 3 Wege Umschaltventil...

Page 34: ...nwater cistern is full enough with the water level above level 1 the system runs in rainwater mode When required service water is pumped from the cistern to the consumer If the water level drops to be...

Page 35: ...r level in the cistern rises above level 4 any automatic or manual drinking water feeding is switched off and locked cannot be swit ched on manually either Drinking water feeding can only be activated...

Page 36: ...y only be carried out by the manu facturer The switch unit does not require any mainten ance The floating switch must be checked for soiling and alignment at regular intervals It must al ways be handl...

Page 37: ...ment and not ne cessarily to the entire product or unit KES SEL products are warranted for a period of 24 month This warranty period begins on the day the product is shipped form KES SEL to its custom...

Page 38: ...EEC Electromagnetism Guidelines 89 336 EEC Low Voltage Guidelines 73 23 EEC Kessel AG D 85101 Lenting we declare that the product Type KESSEL Control unit Aqatronic S is in agreement with EN 55014 EN...

Page 39: ...e Fax Authorised acceptance representative Address Phone Fax Person handing over Other comments The putting into service according to the EBA and instruction was carried out in the presence of the aut...

Page 40: ...verschl sse Hebeanlagen Abl ufe Rinnen innerhalb von Geb uden Abl ufe au erhalb von Geb uden Abscheider Fettabscheider l Benzinabscheider St rkeabscheider Sinkstoffabscheider Kleinkl ranlagen Sch chte...

Reviews: