background image

I. Product Details

KESD KF-06W is a kind of dedicated device for eliminating static
electricity, belonging to one type of ion fan series with characteristics
of simple installation, steady work and fast static electricity
eliminating speed. It is an ideal product widely used in static
electronic products, electronic assembly line, packaging and small
product molding, etc. industries.
This machine is a kind of portable ion fan, using small fan to produce
iron airflow.
The front air window of the machine is straight line grid type, making
the wind blown out have linearity, increasing static electricity
eliminating effect. Before maintenance, the fan is convenient for
disassembly.
The machine spray point is easy for disassembly; meanwhile, you
needn’t to worry about secondary pollution resulting from the dust
produced during cleaning tungsten needle.
This machine is designed for some sensitive electronic components

and electrostatic leakage, etc. problems. It can also be used in the
environment with some problems caused by static electricity, for
example, occasions of static electricity adsorption, malposition of
components and parts due to electrostatic interaction and colloid
adhered due to static electricity.
This machine can produce ion airflow in set area. The time needed for
static electricity neutralization depends on many factors, mainly
having two facotrs:
First, effective distance; in effective distance, ions in air constantly
neutralize with each other; positive negative ions attract each other
due to static electricity; when phase collides, electric charge
transforms and irons reintegrate.
Second, air flow velocity; in the situation of fast air flow, irons also
flow fast before recombination; set wind speed to the highest speed,
the fastest neutralization effect can be obtained.
Use this machine in the electronic products production region; this
area must be covered by ion wind as far as possible and regional

Summary of Contents for KF-06W

Page 1: ... Address No 625 Binhe Road High tech Zone Suzhou City Service hotline 400 888 9280 Product executing standard Q 320505KESD01 Thank for your patronage Before using this product please read this operating manual carefully so as to correctly use it Please keep it properly after reading for later consultation Ion Fan Operating Manual KF 06W ...

Page 2: ...n Figure 3 Ⅳ Product Property Parameters 4 Ⅴ Product General Assembly Drawing 5 Ⅵ Rear Label Description 6 Ⅶ Product Explosive View 7 Ⅷ Assembly Operation 8 Ⅸ Matters Needing Attention 10 Ⅹ Maintenance 12 Ⅺ After sales Service 14 Ⅻ Common Fault Elimination 15 ⅩⅢ Packing List 17 ...

Page 3: ... is designed for some sensitive electronic components and electrostatic leakage etc problems It can also be used in the environment with some problems caused by static electricity for example occasions of static electricity adsorption malposition of components and parts due to electrostatic interaction and colloid adhered due to static electricity This machine can produce ion airflow in set area T...

Page 4: ...bled convenient for cleaning maintenance and replacement Unique network power socket convenient for series connection and wiring Ⅲ Product External Dimension Drawing Ⅳ Product Property Parameters 1 Specification Specification Operating Voltage DC24V Operating Temperature 0 40 Decay Time About 1 3s 200mm Weight 0 45kg Air Volume 0 55 0 71m3 min Ion Balance Automatic iron balance system within 0 10V...

Page 5: ...e Positive 1 3s 1 9s Negative 1 4s 2s Offset Voltage Positive 0 10V Negative Note destaticizing property is determined according to America specification EOS ESD STM3 1 2000 Test data will be changed due to the environment in test Ⅴ Product General Assembly Drawing Ⅵ Rear Label Description Shell Nut Support frame Front air window Indicator light ...

Page 6: ...ype power interface 7 Rear air window protecting net Ⅷ Installation and Operation 1 This design is convenient for installation Its base can be fixed to a surface with bolts such as wall or shelf if the base is fixed to a certain place fix it with M6 1 4 inch screws or bolts 2 This machine is placed in a position less than 300mm from the working area or the article to be neutralized and this area m...

Page 7: ...he article and adjust the angle then static electricity can be eliminated 3 Can use this product in series at the same time convenient for wiring Ⅸ Matters Needing Attention Danger 1 The spray point has high voltage and may result in electric shock please never contact spray point on power up state 2 When checking cleaning and maintaining products please be sure to shut off the power otherwise it ...

Page 8: ...k ozone otherwise it may cause nose or throat etc position ache 2 The service life of the spray point is varied due to operating environment If the operating environment is bad i e environment with too high temperature or the spray point hasn t been washed for a long time its performance may be declined therefore must maintain it regularly 3 Please note impulse current will be flowed in when openi...

Page 9: ...ir window with non dust cloth dipped with alcohol until it is clean 2 Cleaning of the tungsten needle spray point a Abrasively cleaning the tungsten needle tip with fine grit sandpaper as shown in figure b Wipe and clean the tungsten needle with cotton bud dipped with alcohol as shown in following figure Ⅺ After sales Service 1 Maintenance period The warranty period of the product sold by the comp...

Page 10: ...s bad or falls off 1 Reinsert or replace power supply 2 Re connect internal lead 2 The indicator 1 The connecting 1 Re connect the light is on there is high voltage output but the fan doesn t rotate or the rotating speed is not stable line is broken 2 High voltage control panel is damaged lead 2 Replace the control panel 3 The machine is running normally but no high voltage is generated 1 The base...

Page 11: ...ⅩⅢ Packing List 1 Ion fan One set 2 Power supply One 2 Specification One 4 Warranty card One 3 Test report One copy 6 Certificate of conformity One ...