9.5  Input minimum weight for some functions 

 
The minimum weight affects the following functions: 
 

Automatic taring 

(Chpt. 8.11): In order to apply this function, the weight of the 

weighing plate must have dropped below the entered weighing value first, before 
another greater weight can be tared automatically.  
 

Automatic output function 

(Chpt. 9.4): If the current weighing value exceeds the 

entered weighing value, a weighing value will be issued automatically. The next 
weighing value will not be issued unless the weighing value has meanwhile dropped 
below the entered weighing value. 
 
 
 

Operation:  

Display: 

Ö

  Selecting the menu item 

P2 Prnt

 

Ö

 Press 

TARE

 key 

2.1. Pr_n 

Ö

 Press the 

a

 key

 

2.2. S_Lo 

Ö

 Press 

TARE

 key 

0010.00g

 

Ö

  Enter the minimum weight  (e. g. 30.00 g). Use the 

TARE

 

key, to select the digit to be changed, the 

a

 key is 

used to increase the numerical value (active digit flashing) 

0030.00g 

Ö

 Press the 

PRINT

 key; the minimum weight will be 

imported. 

2.2. S_Lo

 

 
For this, press the 

F

 key repeatedly until 

SavE ?

 appears on the display. Store  

changes carried out by pressing the 

PRINT

 key. 

 

KLB-TM-BA-e-0811 

40

 

Summary of Contents for KLB-TM

Page 1: ...mbH Ziegelei 1 D 72336 Balingen E Mail info kern sohn com Tel 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www kern sohn com Operating Manual Display units KERN KLB TM Version 1 1 01 2008 GB KLB T...

Page 2: ...________________________ 10 6 2 Unpacking ______________________________________________________ 10 6 2 1 Setup ______________________________________________________________ 10 6 2 2 Scope of deliver...

Page 3: ..._____________________________________________________ 29 8 7 4 Median filter _________________________________________________________ 30 8 8 Parts counting ___________________________________________...

Page 4: ...Parameter description for configuration _____________________________ 49 13 3 Calling menu for entering parameter of configuration __________________ 50 13 4 Default adjustment parameter P 0 9 CAL ___...

Page 5: ...power supply Standard Weighing cell connection 4 or 6 wire Linearization 6 points Interface RS232 Appropriate for verification yes Reference quantities at piece counting 10 20 50 freely selectable We...

Page 6: ...as Produkt auf das sich diese Erkl rung bezieht mit den nachstehenden Normen bereinstimmt Fran ais Nous d clarons avec cela responsabilit que le produit auquel se rapporte la pr sente d claration est...

Page 7: ...al que se refiere esta declaraci n est de acuerdo con las normas siguientes Esta declaraci n solo ser v lida acompa ada del certificado de conformidad de una instituci n nombrada Italiano Dichiariamo...

Page 8: ...ystem Impacts and overloading exceeding the stated maximum load max of the weighing plate minus a possibly existing tare load must be strictly avoided Both the weighing plate and the display unit may...

Page 9: ...ions 4 1 Pay attention to the instructions in the Operation Manual Carefully read this operation manual before setup and commissioning even if you are already familiar with KERN balances 4 2 Personnel...

Page 10: ...h humidity vapours and dust Do not expose the display unit to extreme dampness for longer periods of time Non permitted condensation condensation of air humidity on the appliance may occur if a cold a...

Page 11: ...lectronic display units the display unit must have reached its operating temperature see warming up time chapter 1 During this warming up time the display unit must be connected to the power supply ma...

Page 12: ...t by using a recommended calibration weight The weighing value is determined during the configuration of the weighing cell See chpt 13 4 Factory settings Procedure when adjusting Observe stable enviro...

Page 13: ...s the F key The display unit returns to weighing mode SAuE 0 00 g Message Err 4 appears for a calibration error or incorrect test weight In this case repeat the calibration sequence Keep the test weig...

Page 14: ...ESC Function key to select operating mode PRINT Printout of the weighed value on an external appliance printer or PC 0 Set weight display at zero TARE Taring The display unit carries out an automatic...

Page 15: ...weight storage 10 0 Weight display at 0 11 Display value is stable 12 PCS Display operating mode piece counting 13 kg g Display operating mode weighing 14 Low battery level battery charge status or da...

Page 16: ...Func 4 1 FFun ALL Parameter for selection with F key 4 2 Funi YES Weighing units switch over 4 3 PcS YES Parts counting 4 4 HiLo YES Tolerance weighing 4 5 PrcA YES Percentage weighing by means of we...

Page 17: ...ing up menu Turn on display unit by pressing the ON OFF key Press the F key and PRINT key simultaneously To go from P1 rEAD to P6 CAL in the menu press the a key repeatedly 8 2 2 Storing jumping back...

Page 18: ...ard weighing unit Selected weighing unit will be retained even after disconnection from the mains Operation Display Turn on display unit by pressing the ON OFF key 0 00 g Press the F key and PRINT key...

Page 19: ...ay unit by pressing the ON OFF key 0 000 kg Press F key 1 Funi Press TARE key 0 000 kg To change your selection press the a key 0 000 lb To change your selection press the a key 0 000 N Setting will b...

Page 20: ...ner Read the weight of the goods on the display 53 25 g The taring process can be repeated any number of times e g when adding several components for a mixture adding The limit is reached when the who...

Page 21: ...he a key until P4 Func appears P4 Func Press TARE key 4 1 FFun Press TARE key ALL All operating modes enabled in menu 4 2 to 4 9 are callable via the F key Press the a key Funi Weighing Units Press th...

Page 22: ...Press TARE key 4 1 FFun Press the a key 4 2 Funi Press the a key until the operating mode piece counting appears 4 3 PcS Press the TARE key until active setting appears no deactivated yes activated no...

Page 23: ...kground lighting is turned off automatically every 20 seconds if no change of display takes place Operation Display Selecting the menu item P5 othr Press TARE key 5 1 bl Press TARE key Auto To change...

Page 24: ...hting is turned off automatically every 20 seconds if no change of display takes place Operation Display Selecting the menu item P5 othr Press TARE key 5 1 bl Press the a key 5 2 blbA Press TARE key 2...

Page 25: ...be shut off if no weighing takes place within the next 5 minutes t1 no No shut off of display unit Operation Display Selecting the menu item P5 othr Press TARE key 5 1 bl Repeatedly press the a key un...

Page 26: ...ation of the battery symbol if the weighing unit is operated without battery or accumulator supply by power pack The kind of supply is shown when the balance is started bAtt SLA nlnnH CHr6 YES nlnnH F...

Page 27: ...nominal capacity of the batteries reached 8 7 P1 rEAd basic settings 8 7 1 Filter settings This menu item allows the display unit to be set according to specific ambient conditions and measuring purpo...

Page 28: ...balance evaporating processes When apportioning involves small variations of weight it is advisable to switch off this function Auto Zero no Disconnection of auto zero function Auto Zero YES Auto zer...

Page 29: ...rage of last tare value Value is displayed showing minus sign when balance is started and as a NET symbol on the display User can turn on automatic tare function via F6 AtAr and this will remain activ...

Page 30: ...1 rEAd Press TARE key 1 1 Fil Repeatedly press the a key until the following display appears 1 4 Fnnd To change your selection press the TARE key no To change your selection press the a key YES Settin...

Page 31: ...F key 0 00 g Press F key 1 Funi Press the a key 2 PcS Press TARE key FrEE To set the reference number of items on the display press the a key repeatedly A selection of 10 20 50 or FrEE to be picked at...

Page 32: ...play and the display unit s display will return to weighing mode 8 9 Percent determination Percent determination allows weight display in percent in relation to a reference weight 8 9 1 Determination...

Page 33: ...y 0100 00 g Enter the reference weight e g 90 33 g Use the TARE key to select the digit to be changed the a key is used to increase the numerical value active digit flashing 0090 33 g Press PRINT key...

Page 34: ...tive digit flashing Min 0090 00g Press the PRINT key the lower tolerance limit will be imported To enter the upper tolerance limit e g 110 00 g Use the TARE key to select the digit to be changed the a...

Page 35: ...ods to be weighed on weighing plate 123 45 g A stable weighing value will start automatic taring The display shows NET 0 00 g Place weight in weighing container net weight of weighed item will be show...

Page 36: ...hown Operation Display Turn on display unit by pressing the ON OFF key 0 00 g Press F key 1 Funi Repeatedly press the a key until 7 toP appears 7 toP Press TARE key Max 0 00 g Place weight on weighing...

Page 37: ...0 5 kg on weighing plate 0 500 kg Press print key import to summation memory 0 700 kg To cancel current summation press the Print key again and the following message will appear unLoAd Unload weighin...

Page 38: ...nsmission modes are available Manually after pressing the PRINT key Continuously according to setting Automatically according to stability display Prompted by external device For remote control comman...

Page 39: ...he PRINT key 2 1 Pr_n For this press the F key repeatedly until SavE appears on the display Store changes carried out by pressing the PRINT key Meaning of settings noStAb immediate data output even if...

Page 40: ...tomatically The next weighing value will not be issued unless the weighing value has meanwhile dropped below the entered weighing value Operation Display Selecting the menu item P2 Prnt Press TARE key...

Page 41: ...a key twice until 2 3 bAud appears on the display 2 3 bAud Press TARE key 9600 To change your selection press the a key 19200 38400 2400 4800 9600 Press the PRINT key the baud rate will be imported 2...

Page 42: ...Press the PRINT key the selection will be imported 2 3 bAud For this press the F key repeatedly until SavE appears on the display Store changes carried out by pressing the PRINT key Meaning of settin...

Page 43: ...tandard weighing unit CU1 Turn on continuous transmission in current weighing unit CO1 Turn off continuous transmission in current weighing unit PC Send all implemented instructions Complete each inst...

Page 44: ...Presign Space if positive negative sign if negative Weight 9 signs right justified Unit 3 signs left justified 9 8 2 Manual output The user may start output by pressing the PRINT key Settings in chap...

Page 45: ...smission in standard weighing unit CU1 CR LF Turn on continuous transmission in current weighing unit CO1 CR LF Turn off continuous transmission in current weighing unit Data record format 1 2 3 4 5 6...

Page 46: ...Service maintenance disposal 11 1 Cleaning Before cleaning please disconnect the appliance from the operating voltage Please do not use aggressive cleaning agents solvents or similar agents but a clo...

Page 47: ...nserted The displayed weight is permanently changing Draught air movement Table floor vibrations Weighing plate has contact with other objects Electromagnetic fields static charging choose different l...

Page 48: ...e unit The contact tabs for the weighing cell are positioned on the top left hand corner of the board Anschluss Function AGND Dimensions of weighing cell 5 V Supply for weighing cell IN Signal of weig...

Page 49: ...0 1 Adjustment weight in respect of maximum load P 0 8 St_u Initial weight for adjustment P 0 9 CAL Default adjustment P 0 A Gcor 1 00000 0 90000 1 10000 Factor for gravity constant P 0 b LFt no no ye...

Page 50: ...usly After the menu was called select P 0 FAct by pressing the a key For navigation around menu refer to chapter 8 2 To call specific parameters press the TARE key To change the parameter press the a...

Page 51: ...nce this is completed LoAD will appear on the display followed by the weight value of the adjustment weight value of P 0 7 wEi Place the adjustment weight on the weighing plate and press the PRINT key...

Page 52: ...one DonE appears on the display and subsequently returns to the menu on the display appears 0 L LinE If less than 6 linearization points are necessary press the F button when the message nEHt appears...

Page 53: ...r supply No No Bat Lo display SLA 6V battery block Bat Lo display appears when voltage drops below 5 7 V nimh 6 x 1 2V battery block type AA Bat Lo display appears when voltage drops below 7 2 V Atten...

Reviews: