KERN HTS-A Operating Manual Download Page 7

HTS_A-BA-e-1531

 

  Major display deviations (incorrect weighing results) may be experienced should 

electromagnetic fields (e.g. due to mobile phones or radio equipment), static 
electricity accumulations or instable power supply occur. Change location or 
remove source of interference.  

2.4 

Proper use 

The balance you purchased is intended to determine the weighing value of material 
to be weighed.  It is intended to be used as a “non-automatic“ balance, i.e. the 
material to be weighed is suspended on the crane hook only vertically, manually, 
carefully and without jerks.  As soon as a stable weighing value is reached the 
weighing value can be read. 
 

  Use the crane scales only for lifting and weighing of freely movable loads. 

  Danger of injury due to improper use. Not allowed are e.g.: 

Exceeding the allowed nominal load of crane, crane scales or any type of 
load attachment devices 

Conveying persons, 

Pulling loads over an inclined surface, 

Tearing-off, pulling or towing loads. 

  Modifications or reconstructions of the crane scales or of the crane are not 

allowed. 

 

2.5 

Improper Use 

Do not use balance for dynamic weighing. In the event that small quantities are 
removed or added to the material to be weighed, incorrect weighing results can be 
displayed due to the “stability compensation“. (Example: Slowly draining fluids from a 
container suspended on the balance.) Do not leave permanent load suspended on 
the balance. This may damage the measuring system as well as safety-relevant 
parts. 
 
The balance may only be used according to the described conditions. Other areas of 
use must be released by KERN in writing. 
 

2.6 

Warranty 

Warranty claims shall be voided in case    

  Our conditions in the operation manual are ignored 

  The appliance is used outside the described uses 

  The appliance is modified or opened 

  Mechanical damage and damage caused by media, liquids,  

  Natural wear and tear 

  The appliance is improperly set up or incorrectly electrically connected 

  The measuring system is overloaded 

 
 

 

Summary of Contents for HTS-A

Page 1: ...alingen E Mail info kern sohn com Phone 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www kern sohn com Operating manual Electronic Crane Scales Logbook Regular maintenance and care KERN HTS A Vers...

Page 2: ...t a glance __________________________________________________ 9 3 1 Overview__________________________________________________________________________ 9 3 2 Display ___________________________________...

Page 3: ..._________________ 25 8 Cleaning and Disposal_______________________________________________________ 25 8 1 Cleaning and Disposal _____________________________________________________________ 25 9 Main...

Page 4: ...5 t M2 3 t M2 6 t M2 10 t M2 Stabilization time 2 s Warm up time 10 min Unit kg Allowable ambient temperature 20 50 C Relative humidity 10 to 95 non condensing Input voltage Appliance 110V 230V AC Inp...

Page 5: ...5 HTS_A BA e 1531 1 1 Dimensions mm A B C D E F HTS 1T 4AM 37 29 32 5 314 6 12 7 33 3 HTS 3T 3AM 56 47 42 5 346 75 17 5 42 9 HTS 6T 3AM 60 55 54 440 24 6 58 HTS 10T 3AM 79 61 58 535 35 35 82 6...

Page 6: ...mmissioning and maintenance should only be carried out by trained specialists Repair of safety relevant pieces may only be carried out by KERN or by service partners authorized by Messrs KERN competen...

Page 7: ...ons Pulling loads over an inclined surface Tearing off pulling or towing loads Modifications or reconstructions of the crane scales or of the crane are not allowed 2 5 Improper Use Do not use balance...

Page 8: ...libration laboratory test weights and balances may be calibrated return to the national standard fast and at moderate cost 2 9 Testing upon acceptance When receiving the appliance please check packagi...

Page 9: ...weighing applications such as e g recycling metal processing machine engineering transport and logistics With the infrared remote control operation will be more comfortable yet 3 1 Overview Balance 1...

Page 10: ...ight 2 Indicator zero display 3 Indicator gross weight 4 Stability display 5 Battery charge display 3 3 Keyboard Button Description of function Zeroing Taring Gross weight Net weight Background illumi...

Page 11: ...ected The red LED must light up when any button is pressed If it does not light up the batteries in the remote control must be exchanged Range on free surface free of buildings approx 10 m Point the r...

Page 12: ...HTS_A BA e 1531 12 3 6 Label Do not stand or go under suspended loads Do not use on building site Keep an eye on suspended loads example Do not exceed nominal load of crane scales...

Page 13: ...Quality assurance team Danger for the back The crane scales are compact and quite heavy Remove the scales from packaging only with the help of a second person Use a lifting device such as a crane or a...

Page 14: ...rgeable battery operation CAUTION Material damage on crane scales Only use the delivered mains adapter Make sure that the mains adapter the cable and the mains plug are in a perfect condition Do not u...

Page 15: ...crane scales cannot fall down If the safety bracket is missing or damaged please contact the crane manufacturer in order to receive a hook with this safety equipment Suspend the crane scales on the l...

Page 16: ...es chains etc for excessive wear or damage If faults can be seen on the safety bracket of the hook or if it is missing completely the scales must not be used Work only with appropriate speed Always av...

Page 17: ...Do not use multiple suspensions Do not pull or push the load or the loaded balance Do not pull the hook horizontally Loading the balance 1 Position the hook of the crane scales over the load 2 Move do...

Page 18: ...31 18 Only use load attachment devices which guarantee a one point suspension and where the scales can be suspended freely Do not use too large load attachment devices which cannot guarantee a one poi...

Page 19: ...19 HTS_A BA e 1531 Do not push or pull Do not pull the hook horizontally Do not use multiple suspensions...

Page 20: ...For verified balances pay attention to check number The check number will be shown after the balance has been turned on This number will be adjusted automatically after each adjustment activity In ver...

Page 21: ...s on the keyboard of the remote control unit the balance is in standby mode 5 4 Set balance to zero In order to obtain optimal weighing results reset to zero the balance before weighing Unload the bal...

Page 22: ...layed at once Overload warning Overloading exceeding the stated maximum load max of the balance minus a possibly existing tare load must be strictly avoided This could cause damage to the balance Exce...

Page 23: ...ioning after each change of location as well as in case of fluctuating environment temperature To receive accurate measuring values it is also recommended to adjust the balance periodically in weighin...

Page 24: ...ere the balance is used must be observed Verification of the balance is invalid without the seal The seal marks attached on balances with type approval point out that the balance may only be opened an...

Page 25: ...harge battery Should other error messages occur switch balance off and then on again If the error message remains inform manufacturer 8 Cleaning and Disposal 8 1 Cleaning and Disposal CAUTION Damage o...

Page 26: ...ried out by service partners authorized by Messrs KERN 9 1 Regular maintenance and care The regular 3 month maintenance may only be carried out by an expert with competent knowledge of working with cr...

Page 27: ...alance must be repaired at once by trained specialized staff KERN customer service Never do repair it by yourself Take balance out of operation immediately All repairs and spare parts must be document...

Page 28: ...ound in the document attached to the balance Please keep this document always available Shackle Hooks Anchor eyelets a b c Wear and tear see grey fields Split pin Nut d e Wear and tear see grey fields...

Page 29: ...Revision prior to first use 24 months 100 000 x 27 months 112 500 x 30 months 125 000 x 33 months 137 500 x 36 months 150 000 x 39 months 162 500 x 42 months 175 000 x 48 months 200 000 51 months 212...

Page 30: ...HTS_A BA e 1531 30...

Page 31: ...zed by KERN Crane scales Model Serial no Interval Magnetic powder test for cracks Shackle Hooks Anchor eyelets Date Name Signature 12 months 50 000 x 24 months 100 000 x 36 months 150 000 x 48 months...

Page 32: ..._A BA e 1531 32 10 2 List spare parts and repair of safety relevant parts Repair has to be carried out by a service partner authorized by KERN Crane scales Model Serial no Part Action Date Name Signat...

Page 33: ...HTS_A BA e 1531 33 Crane scales Model Serial no Part Action Date Name Signature...