background image

GB 

 

 

Operating Instructions Hanging scale

 

 

 

1 Technical 

data 

 

KERN 

HDB 5K5 

HDB 10K10 

Readout (d) 

5 g 

10g 

Weighing range (Max) 

5 kg 

10kg 

 

2 Basic 

instructions 

2.1 

Proper use 

The balance you purchased is intended to determine the 
weighing value of material to be weighed. It is intended to be 
used as a “non-automatic“ balance, i.e. the material to be 
weighed is manually and carefully suspended. As soon as a 
stable weighing value is reached the weighing value can be 
read. 

2.2 

Improper Use 

Do not use balance for dynamic weighings. In the event that 
small quantities are removed or added to the material to be 
weighed, incorrect weighing results can be displayed due to the 
“stability compensation“ in the balance. (Example: Slowly drain-
ing fluids from a container suspended on the balance.) No 
permanent load must remain on the balance. This may dam-
age the measuring system. 
Impacts and overloading exceeding the stated maximum load 
(max) of the balance, minus a possibly existing tare load, must 
be strictly avoided. Balance may be damaged by this (danger 
of breaking). 
 

Caution:  

Ö

  Make sure that never persons or objects are under the 

load which could be injuried or damaged! 

Ö

  The balance is not suitable for weighing persons! 

Ö

  The balance does not correspond to the law of medical 

products (MPG). 

Never operate balance in explosive environment. The serial 
version is not explosion protected. 
The structure of the balance may not be modified. This may 
lead to incorrect weighing results, safety-related faults and 
destruction of the balance. 
The balance may only be used according to the described 
conditions.  
Other areas of use must be released by KERN in writing. 

 

2.3 

Warranty 

Warranty claims shall be voided in case  

 

 

Our conditions in the operation manual are ignored 

 

The appliance is used outside the described uses 

 

The appliance is modified or opened, 
mechanical damage and damage caused by media, liquids 

 

Natural wear and tear 

 

The appliance is improperly set up or incorrectly electri-
cally connected 

 

The measuring system is overloaded 

2.4 

Monitoring of Test Resources 

In the framework of quality assurance the measuring-related 
properties of the balance and, if applicable, the testing weight, 
must be checked regularly. The responsible user must define a 
suitable interval as well as type and scope of this test. Informa-
tion is available on KERN’s home page (www.kern-sohn.com) 
with regard to the monitoring of balance test substances and 
the test weights required for this. In KERN’s accredited DKD 
calibration laboratory test weights and balances may be cali-
brated (return to the national standard) fast and at moderate 
cost. 

Basic Safety Precautions 

Ö

  Do not use the suspended balance for conveying loads 

Ö

  Never exceed the maximum permitted load (!!Danger of 

breaking!!). 

Ö

  Always ensure that there are 

no persons, animals or 

objects

 that might be damaged underneath the load. 

Ö

  Avoid any kind of shock, torsion and oscillating (e.g. 

caused by inclined suspending)  

 

 

3.1 

Pay attention to the instructions in the Operation Man-
ual 

Carefully read this operation manual before commissioning, 
even if you are already familiar with KERN balances. 

3.2 Personnel 

training 

The appliance may only be operated and maintained by trained 
personnel. 

 

 

Summary of Contents for HDB 5K5

Page 1: ...bH Ziegelei 1 D 72336 Balingen E Mail info kern sohn com Tel 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www kern sohn com Operating Instructions Hanging scale KERN HDB N Version 1 3 04 2011 GB HDB N BA e 1113 ...

Page 2: ... the balance The balance may only be used according to the described conditions Other areas of use must be released by KERN in writing 2 3 Warranty Warranty claims shall be voided in case Our conditions in the operation manual are ignored The appliance is used outside the described uses The appliance is modified or opened mechanical damage and damage caused by media liquids Natural wear and tear T...

Page 3: ... key and keep it pressed Ö Do not release the HOLD key Press also the ON OFF TARE key and keep it pressed Ö Keep the ON OFF TARE key pressed however release the HOLD key Ö Press HOLD key anew Ö Keep both keys pressed until in the display tr appears Ö Release both keys The balance is situated in the menu Ö Press the ON OFF TARE key until AF appears Confirm the selection of the Auto Off function usi...

Page 4: ... Press the HOLD key the display counts reverse from 3 1 The calculated mean value is indicated symbolised by the S top left Ö For further measurements press the ON OFF TARE key before 7 4 3 Peak value function This function displays the highest load value peak value of a weighing Measuring frequency 200ms Caution Never exceed the maximum permitted load of the peak value on the balance Danger of br...

Reviews: