- 13 -
DAB-SH-e-1610
4.3 Halogen Error
No
Problem
Solution
1
Not heating
The temperature set too lower, please reset the
temperature
The mode soft with lower temperature,will light soft,it
looks not heating
The lamp broken,it will show the white fog inside.
The Filament broken. Please check the lamp first
Lamp life is reached, there will show black smoke inside.
2
Temperatureis not
reached
The input voltage is to low (220 V / 110V)
The temperature sensor is broken.
3
Not stop heating
The temperature control IC in main-board broken.
The lamp continue heating and not stop,it will broken the
machine, it means temperature control broken, need
change.
4
Temp Sensor
After a long use the sensor will be dirty. You have to
clean it from time to time.
5
Tempcalibration
Must use our calibration meter and put on the pan
center,useSoft mode with manual stop, and check the
temperature.
See 4.3.1