background image

BIC

-

BA-e-1610 

 

 

KERN 

BIC 1T-4 

BIC 3T-3 

BIC 3T-3L 

Readability (d) 

200 g; 500 g 

500 g; 1,000 g 

500 g; 1,000 g 

Weighing range (max) 

600 kg; 1,500 kg 

1,500 kg; 3,000 

kg 

1,500 kg; 3,000 

kg 

Reproducibility 

500 g 

500 g; 1,000 g 

500 g; 1,000 g 

Linearity 

± 1 kg 

± 1.5 kg; 3 kg 

± 1.5 kg; 3 kg 

Recommended 
adjustment weight, not 
added (class) 

1.5t 

(M2) 

3000 kg 

(M2) 

3000 kg 

(M2) 

Warm-up time 

10 minutes 

Stabilization time (typical) 

2 s 

Weighing unit 

kg, lb 

Auto Off 

3 min. 

Ambient temperature 

-10

 – 40

 

Humid environment 

0 % - 80 % (non-condensing) 

Electric Supply 

Input voltage 100 V - 240 V, 50 / 60 Hz 

Power pack secondary voltage 9V, 100mA 

Dimensions display unit 
(B x D x H) mm 

235 x 114 x 51 

235 x 114 x 51 

235 x 114 x 51 

Weighing surface mm 

1200×1500 

1200×1500 

1500 x 1500 

Net weight kg 

150 

150 

150 

 
 

Summary of Contents for BIC 1T-4S

Page 1: ...Operating manual Floor scales KERN BIC Version 1 0...

Page 2: ...l 9 4 2 Personnel training 9 5 Transport and storage 9 5 1 Testing upon acceptance 9 5 2 Packaging return transport 9 6 Unpacking and placing 10 6 1 Installation Site Location of Use 10 6 2 Unpacking...

Page 3: ...BIC BA e 1610 3 9 2 Servicing maintenance 18 9 3 Disposal 18 10 Error messages troubleshooting guide 19 11 Declaration of conformity 20...

Page 4: ...ded adjustment weight not added class 600 kg M2 600 kg M2 1 5t M2 Warm up time 10 minutes Stabilization time typical 2 s Weighing unit kg lb Auto Off 3 min Ambient temperature 10 C 40 C Humid environm...

Page 5: ...ded adjustment weight not added class 1 5t M2 3000 kg M2 3000 kg M2 Warm up time 10 minutes Stabilization time typical 2 s Weighing unit kg lb Auto Off 3 min Ambient temperature 10 40 Humid environmen...

Page 6: ...e 1610 2 Appliance overview display unit 1 Weight display 2 Buttons 3 Battery compartment 4 Guide rail support base stand 5 End stop support base stand 6 Mains adapter connection 7 Connection load ce...

Page 7: ...or added to the material to be weighed incorrect weighing results can be displayed due to the stability compensation in the display unit Example Slowly draining fluids from a container on the balance...

Page 8: ...or incorrectly electrically connected The measuring system is overloaded 3 4 Monitoring of Test Resources In the framework of quality assurance the measuring related properties of the display unit and...

Page 9: ...5 1 Testing upon acceptance When receiving the appliance please check packaging immediately and the appliance itself when unpacking for possible visible damage 5 2 Packaging return transport Keep all...

Page 10: ...is case acclimatize the disconnected appliance for approx 2 hours at room temperature Avoid static charge of goods to be weighed or weighing container Major display deviations incorrect weighing resul...

Page 11: ...isplay unit periodically in weighing operation The adjustment weight to be used depends on the capacity of the weighing system Carry out adjustment as near as possible to the weighing system s maximum...

Page 12: ...will sound Adjustment will be performed Then the balance returns automatically into the weighing mode An error message will be displayed in the event of an adjustment error or incorrect adjustment we...

Page 13: ...despite empty scale pan press the button The balance will be set to zero after a short standby time 7 2 Switching Off Switch off balance with the display will go off 7 3 Zeroing Resetting to zero corr...

Page 14: ...eighing container will be displayed Press the zero display appears The indicator NET is displayed The tare weight is saved until it is deleted Weigh the material the net weight will be indicated The t...

Page 15: ...weighing goods and press The display will be blinking HOLD and the indicator hold appears During this time the balance takes up several measured values and displays then the calculated mean value Thi...

Page 16: ...g mode UF 1 is displayed Press as often as necessary until the required function is displayed Confirm selected function by The current setting will be displayed Select the desired parameter with Retur...

Page 17: ...function animal weighing function Adjustable Average value is calculated for unstable weighing conditions from approx 20 d Average value is calculated for unstable weighing conditions from approx 5 d...

Page 18: ...d soap suds Take care that the device is not penetrated by fluids and polish it with a dry soft cloth 9 2 Servicing maintenance The appliance may only be opened by trained service technicians who are...

Page 19: ...hing pan has contact with other objects Electromagnetic fields static charging choose different location switch off interfering device if possible The weighing result is obviously incorrect The displa...

Page 20: ...1000x1000...

Page 21: ...1200 x 1500...

Page 22: ...A B B 1500 1290 0 2 1450 276 23 145 67 5 M5 1500 1450 1290 0 2 25 4 76 2 0 1 30 180 30 27 23 25 25 13 40 160 215 100 500 100 215 160 160 201 100 100 201 160 5 75 60 4 M12 1040 1040 508 40 1500 x 1500...

Reviews: