background image

Installation Instructions Credo-V

Use exclusively these instructions for installing radiators equipped
with control valves.

II

Symbols Used

1)

Suitable fittings

A

Radiating area

BH Installed height
BL Installed length
BT Overall depth
E

Airvent

G

Weight

H

Distance between mounting studs and inlet/outlet plane

L

Distance between mounting studs

n

Heat-transfer exponent

NA Centre-centre distance between inlet/outlet fittings
NR Article No.
P

Heat output

P1 Power output of electric heating element
V

Water capacity

III

Side and Rear Views

E = Airvent valve or blanking plug

IV

Mounting Points

Plane of inlet/outlet ports

V

Inlet/outlet ports: 1 ea., equipped with G3/4" external pipe threads,
centrally located, both facing downward.  Their centre-centre
spacing is 50 mm (2").  The radiator’s inlet fitting and inlet riser
tube are on its left-hand side, as viewed from the front, as stan-
dard.  In the event that the heating network has been laid out such
that water flows from right to left, as viewed from the front of the
radiator, the radiator’s inlet and outlet may be interchanged by
reversing the plugs in the threaded fittings on the valve manifold.
The airvent port has a G1/4” internal pipe thread and is located on
the rear of the radiator’s left-hand riser tube.

VI

Max. operating pressure: 10 bar,
Pressure-tested at: 13 bar,
Operating medium: Circulating hot water at temperatures of 110°C
or less.

VII Note:

If you installing the radiator on a single-pipe heating system, use a
bypass fitting equipped with a built-in adjustable bypass line.If
auxiliary electric heating is employed, the safety zones stipulated
under current ‘IEE’ regulations must be maintained (radiators must
be installed well away from bathtubs and outside and well away
from shower cubicles.  Electrical outlets and timers must be
located at least 0.6 m (24") from the ends of bathtubs or shower-
cubicles).

VIII Intended Uses

These radiators are intended for indoor heating applications and
drying towels and articles of clothing that have been washed in
water only. Any other type of use does not conform to their
intended use and is thus prohibited.

IX

Maintenance and Cleaning

Trapped air should be bled out of these radiators immediately after
the installation has been filled with water and commissioned and
also after they have been out of use for extended periods. They
should be cleaned with commercially available, mild, nonabrasive,
cleaning agents only.

X

Complaints

Contact the installer or heating contractor if any leaks or other
problems arise.

XI

Note:

Installation and repairs should be performed by a heating-
system installer or heating contractor only. Failure to observe
this requirement will void the warranty.

XII Accessories

Towel hooks (set of 1), airvent valves, blanking plugs, and electric
heating elements equipped  for use with or without room
thermostats and timers.

This section of the installation instructions should be given to
end users!

1

Read these installation instructions through carefully before
installing the radiator.

2

Radiators should be transported and stored in their protective
packagings only.

3

Check the contents of the radiator’s packagings for missing
items and evidence of shipping damage. 

 Verify that all

accessory items supplied are present and undamaged.

A/B Radiator fabricated from circular-cross-section tubing and

equipped with a cover panel

C

Diameter screw 8x80

D

Diameter screw 3.9x60

E

Wall insert 10x60

F

Wall insert S6

G

Spacer

H

Eccentric cap

I

Mounting stud

J

Holder

K

Retaining screw

4

Prepare all tools that will be needed.

Ø6 = 6-mm dia., Ø10 = 10-mm dia., SW 6 = 6-mm Allen wrench
SW 4 = 4-mm Allen wrench, Gr. 3 = #3 Phillips screwdriver
SW 10 = 10-mm open-end wrench, SW 17 = 17-mm open-end wrench
SW 22 = 22-mm open-end wrench, SW 30 = 30-mm open-end wrench

5

Remove the protective foil from the inlet/outlet ports and mounting
points only.  Leave the rest of the protective foil in place until the
radiator has been installed and is ready for use.

Note:

Steps 6 - 8  are  unnecessary for preassembled valve manifolds.  If
you are using a preassembled valve manifold, skip Steps 6 - 8  and
proceed to Step 9.

6

Screw in both pipe-T’s as far as they will go, making certain that
their threaded sections for attaching the valve manifold’s center
section are facing one another and coaxially aligned. These
pipe-T’s may be backed off by as much as a full rotation in order to
line up their threaded sections.

SW 22 = 22-mm open-end wrench

7

Insert the ends of the valve manifold 

(M)

 into the pipe T’s and

center its ends on the threaded fittings on the radiator extensions.

Note:

Each side of the valve manifold has a pair of lathe-turned rings
cut into it (cf. Fig. 8, below) that should be separated from the
union nut on that end of the valve manifold by the same
distance separating the other pair of rings from the union nut
on the other end of the valve manifold.

8

Tighten down both union nuts.

SW 30 = 30-mm open-end wrench

9

Important

Make certain that bearing strength of the floor wall is sufficient to
support the weight of the radiator! Make certain that all necessary
clearances are maintained. Radiators should be at least 50 mm (2")
distant from walls and ceilings!

10

Drill two 10-mm-diameter horizontal holes, each 80-mm-deep,
spaced a distance “L” apart, in the wall for the wall inserts.
(cf. Page 2, Fig. IV, regarding mounting points.)

WARNING!

Exercise extreme caution when drilling any holes in walls!
Make certain that you do not drill into any water, gas, or power
lines! Failure to observe this precaution could lead to fatal
injuries!

Fasten the spacers 

(G)

 to the wall using the wall inserts 

(E)

 and

screws 

(C)

.

SW 6 =  6-mm Allen wrench

11

Rotate the spacers 

(G)

 until their top surfaces are level.

SW 10 = 10-mm open-end wrench

12

Slide the eccentric caps 

(H)

 onto the mounting studs 

(I) 

and screw

the mounting studs 

(I)

 into the tapped holes on the rear of the

radiator 

(A)

. Make certain that both mounting studs 

(I)

 are screwed

in the same distance.  Lift the radiator 

(A)

 and slide the mounting

studs 

(I)

 into the spacers

 (G)

.

Gr.3 = #3 Phillips screwdriver

13

Center the holder 

(J)

 on the bottom of the third rib from the

bottom. Press the retaining screw

 (K)

 into the holder 

(J)

 and screw

it in/out until the radiator 

(A)

 is parallel to the wall. Mark the spot

where the head of the retaining bold 

(K) 

contacts the wall by

drawing a circle around its head with a pencil and then lift the
radiator 

(A)

 off the mounting studs 

(I)

.

14

Drill a single 6-mm-diameter, 60-mm-deep, hole for a wall insert at
the center of the circle.

WARNING!

Exercise extreme caution when drilling any holes in walls!
Make certain that you do not drill into any water, gas, or power
lines! Failure to observe this precaution could lead to fatal injuries!

Insert the small wall insert

 (F)

 into the drilled hole. Fasten the

retaining screw

 (K) 

to the wall using the small-diameter screw

 (D)

.

SW 17 = 17-mm open-end wrench

15

Screw in the bleeder valve 

(L)

.

16

Press the holder 

(J) 

onto the retaining screw 

(K)

. Align the radiator

(A) 

parallel to the wall by screwing the retaining screw 

(K) 

in/out

and then press the eccentric caps 

(H)

 into the spacers

 (G)

.

These eccentric caps (H) serve as retainers that hold the radiator
in place and prevent it from being lifted off the holder (J)!

17

Note:

In the event that the heating network has been laid out such that
water flows from right to left, as viewed from the front of the
radiator, the radiator’s inlet and outlet may be interchanged by
reversing the plugs in the threaded fittings on the valve manifold
(M).  

To reverse these plugs, unscrew them using a 4-mm Allen

wrench and screw them into the other tapped hole in the fitting, as
shown in Fig. 17, above. The radiator’s inlet will now be on the right
and its outlet will be on the left, as viewed from the front.  Reversing
these plugs eliminates need for interchanging the riser tubes.

M

 Outlet

N

 Inlet

18

Connect the radiator’s inlet and outlet to the heating pipes using
suitable fittings and check the entire heating system for water
leaks.

19

Slide the cover plate

 (N)

 onto the riser tubes and press it home

until it abuts firmly up against them.

20

If necessary, the valve’s setting may be adjusted in order to allow
for varying heating-system water temperatures and flow rates
using an adjustment key (Part No. ZHKVESV3k).  This adjustment
key is not included with the radiator, but may be ordered sepa-
rately.

21

Install the thermostatic regulator knob (not included with the
radiator) on the valve’s shaft, if one is to be installed.

22

Put any protective coverings used at the construction site and
the protective foil back onto the radiator (A).

  Remove these

coverings and the protective foil before placing the radiator in
service.

23

Dispose of all packaging materials via a recycling system only.
Scrap radiators and their accessories should be either sent to a
recycling plant or disposed of in accordance with national, state, and
local regulations.

recycling plant or disposed of in accordance with local regulations.
Made in Germany • All rights reserved.
Kermi GmbH • Pankofen-Bahnhof 1 • D-94447 Plattling, Germany
Tel.: +49-(0)9931-5010 • FAX: +49-(0)9931-3075 • http://www.kermi.de

F

Notice de montage Credo-à vanne intégrée

Pour le montage du radiateur à vanne, utiliser uniquement
cette fiche comportant les instructions de montage.

I

Credo-à vanne intégrée

II

Légende

1)

Vissage approprié

A

Surface de chauffe

BH Hauteur de construction réelle
BL Longueur de construction réelle
BT Profondeur de construction
E

Purge

G

Poids

H

Ecart entre la fixation et le centre du tuyau de raccordement

L

Ecart entre les perçages

n

Pente

NA Ecart entre les moyeux
NR Numéro d’article
P

Puissance de chauffe

P1 Puissance de chauffe de la résistance électrique
V

Volume d’eau

III

Vue arrière et vue de profil

E- Bouchon purgeur ou bouchon plein

IV

Cotes de perçages

Bord inférieur du raccordement à vis

IV

Raccordements

Connections 2 x G1/2 (filetage extérieur) à placer au centre dans la
partie inférieure.
Distance du moyeu au mur : 50 mm
Rentrée de série à gauche
Dans le cas d’un circuit avec rentrée à droite, il est possible
d’inverser le sens du passage de l’eau en inversant le montage des
vis cylindriques dans les raccord.
Purge d’air : G1/4 (filet interne) vers l’arrière gauche.

VI

Pression de service: max. 10 bar.
Pression de contrôle: 13 bar.
Conditions de service: eau chaude jusqu’à 110° C.

VII Remarque

Pour le montage sur un chauffage monotubulaire utiliser un
raccord by-pass avec by-pass intégré réglable.En cas de
fonctionnement mixte, veuillez respecter les distances de sécurité
prescrites dans la spécification NF C 15 100 (radiateurs sur le côté,
en dehors du secteur de la baignoire ou de la cabine de douche,
prise de courant et programmateur au moins à 0,6 m sur le côté).

VIII Utilisation autorisée

Le radiateur doit être utilisé uniquement pour chauffer des locaux
fermés et pour sécher des textiles lavés à l’eau.

Toute autre utilisation est non conforme et donc interdite!

IX

Entretien

Purgez le radiateur après la mise en service et après chaque
période d’arrêt de fonctionnement prolongé.
Le nettoyage doit être effectué exclusivement avec votre produit
d’entretien habituel, doux et non abrasif !

X

Réclamations

En cas de dommages, adressez-vous à votre artisan professionnel.

XI

Attention !

Faites effectuer le montage et les réparations exclusivement par un
artisan professionnel sinon votre garantie devient caduque!

XII

Accessoires
crochets 1 à serviettes de bain, bouchon de purge, bouchon aveugle,

résistance de chauffage électrique (avec thermostat réglable).

Cette partie de la notice doit être remise à l’utilisateur final!

1

Lire minutieusement les instructions de montage avant de
procéder au montage !

2

Transport et stockage uniquement dans l’emballage de protection!

3

Vérifier l’intégralité du contenu de l’emballage et les dommages
éventuels!

A/B Radiateur à tuyaux ronds avec cache
C

vis 8 x 80

D

vis 3,9 x 60

E

cheville 10 x 60

F

cheville S6

G

entretoise

H

capuchon excentrique

I

boulon de suspension

J

support mural

K

boulon à fixation immédiate

L

raccord de purge

Gr. = taille, SW = clé Allène

4

Préparer l’outillage nécessaire.

5

Retirer le film protecteur uniquement au niveaux des points de
raccordement et de montage et laisser le reste sur le radiateur
jusqu’à la mise en service.

SW= clé Allène

Remarque :

Si la batterie de vannes est déjà montée, il est inutile d’exécuter

lesétapes 6 à 8 ! Continuer à l’étape 9.

6

Les 2 pièces en T doivent être vissées aussi loin que possible.

En cas de besoin, il est possible de dévisser à nouveau les
raccords en T d’environ un tour.

7

Introduire la batterie de vannes (M) dans les deux raccords en T, et
effectuer son centrage.

Attention !
Les 2 extrémités du tuyau de la pièce centrale comportent une
marque de repère (voiv fig. « = «) ! Ces 2 marques doivent
présenter le même écart des 2 côtés par rapport aux écrous.

8

Serrer les écrous

Библиотека СОК  

Reviews: