Failsafe behavior
Short-circuit
Disconnection indicator
Transmission interrupt
Remote signaling of disconnection
None
Nominal line voltage (Un)
48 Vdc
Max. DC operating voltage (Uc)
60 Vdc
Max. line current (IL)
2A
Protection level (Up)
500V
Nominal discharge voltage 8/20µs
10 kV
Impulse current
2 x 10/350µs Test - D1 Category (Iimp)
100 A
Nominal discharge current
8/20µs Test x 10 - C2 Category (In)
5 kA
Max data rate
1000 Mbps
Certifications
IEC 61643-21 / EN 61643-21
GR1089
ITU-T K.45
UL497B
IEEE 802-3ab/3at
The following picture describes the PoE surge protection:
Figure 77 : PD-OUT/SP11 Microsemi
Note:
the PoE surge protector must be connected to the earth. No cables are provided by
KERLINK for that purpose. See §1.8.4.2 for additional information.