MS-4000: ShootingStar Reader

1530 Old Oakland Road, Suite 100

01815-004 Rev. F

San Jose, CA  95112   USA
(800) 260-5265  (408) 451-2520  FAX (408) 441-0309
Web: http://www.kerisys.com  E-mail: [email protected]

Page 2 of 8

Quick Start Guide

MS-4000

1.2

Operating Voltage

5v to 14v DC @ 50 ma

1.3

Cable Specifications

up to 500 feet using six conductor, shielded, stranded AWG 24 wire (such as Belden 9536)

2.0

Mounting Instructions

There are two methods for mounting the ShootingStar Reader on a solid metal surface (see Figure 1 
on page 1).
1. To mount the reader from the outside, three holes need to be drilled. One through-hole (0.25" – 

1/4") accommodates the reader cable. Two holes correspond with two 1/4", countersunk 
through-holes in the face of the reader (hole size is dependent upon the size of the mounting 
screw). 

2. To mount the reader from the inside, five holes need to be drilled. One through hole (0.25" –    1/

4") accommodates the reader cable. Four 1/4" through holes correspond with four 1/4" x 20 
tapped holes in the back of the reader. Drill these holes to accommodate 1/4" x 20 bolts.

NOTE: Do not mount the reader near sources of Electromagnetic Interference (EMI) such as a 
computer monitor. EMI degrades a reader's read range.

3.0

Connections

The ShootingStar Reader does not require configuration; there are no switches or jumpers to set. 
The ShootingStar Reader is normally connected to a PXL-250, PXL-100, or IntelliProx, but can be 
connected to an alternative host controller/alarm panel through an IntelliProx used in its Wiegand 
input device mode. All connections needed to support the reader are made through the reader's 
cable. Three of the wires on the MS-4000 cable are not used (Brown, White, and Green). Please 
consult the tables on pages 2 and 3 for specific connection instructions.

Summary of Contents for MS-4000

Page 1: ...uide The MS 4000 ShootingStar Reader The MS 4000 ShootingStar Reader is intended for installation on a solid metal surface in proximity applications where a vandal proof reader is required The reader...

Page 2: ...nting screw 2 To mount the reader from the inside five holes need to be drilled One through hole 0 25 1 4 accommodates the reader cable Four 1 4 through holes correspond with four 1 4 x 20 tapped hole...

Page 3: ...3 1 PXL 250 Connections The A reader connects to TB5 pins 1 3 and 4 no connection is made to pins 2 5 6 and 7 The B reader connects to TB6 pins 1 3 and 4 no connection is made to pins 2 5 6 and 7 Conn...

Page 4: ...igure 3 Design 5 PXL 100 Connections NOTE Please contact customer support at Keri Systems for information regarding connecting a Reader to a Design 4 PXL 100 A Design 4 PXL 100 can be identified by th...

Page 5: ...erisys com Page 5 of 8 MS 4000 Quick Start Guide 3 3 IntelliProx Connections The reader is connected to TB1 pins 1 5 and 6 no connection is made to pins 2 3 and 4 Connecting to the IntelliProx TB1 Fig...

Page 6: ...nnunciate reader status the only way to verify reader operation is to present an enrolled card or tag to the reader and see that the door associated with the reader and controller unlocks This is vali...

Page 7: ...either the reader or the device to provide a greater distance between the two 4 A jumper is not set correctly on the controller For a PXL 250 Verify there is a jumper across pins 1 and 2 of JP4 refer...

Page 8: ...eader s cable has opened somewhere between the reader and the controller Verify the shield line from the controller to the reader is one continuous connected line Refer to the controller s installatio...