KEPO KPT-G2223P8 Manual Download Page 4

Ningbo  Kepo  Electronics Co.,Ltd.

http://www.chinaacoustic.com  

Model No. :

Page

Revision No.

Drawing No.

4/10

Specification for Transducer

OEM2336R

1.2

KPT-G2223P8

MIC :   ND10  

普通声级计或等同品

MIC :   ND10   Sound Meter or equivalent

      Part shall be measured under a condition (Temperature :+5 to +35

,Humidity :45 to 

85%R.H.)unless the standard condition (Temperature :+25

±

3

,Humidity :60

±

10

%R.H.) is regulated measure.

  

温度

+25

±

3

℃,湿度

60

±

10%R.H.

标准测试状态

,

在没有疑问的场合

,

可以在温度

+5

+35

,

湿度

45

85%R.H.

的范围内测试

.

压电声响器

piezoelectric sounder  

10cm

5.1   

声压测试线路

      S.P.L. Measuring Circuit

5.2   

测试环境

      Measuring Condition

5.   

测试方法

      Measuring Method

测试条件参见下项

Refer to next item for measuring method.

Amp.

Mic.

4.   

电性能

      Electrical Characteristics

声压

Sound Pressure Level

4.2

4.1

项目

      Item

75dB at 3Vp-p/2.0KHz/10cm

 

      Specification

容量

Capacitance at 100Hz

30000pF

±

30%

S.G. :  DF1010 

振荡器或等同品

S.G. :  DF1010  Oscillater or equivalent

输入信号

:3Vp-p,2.0KHz,

方波

Input Signal:3Vp-p,2.0KHZ,Square wave

Summary of Contents for KPT-G2223P8

Page 1: ...ION Signature of KEPO Approved by Signature of Approval Date Issued by Ningbo Kepo Electronics Co Ltd Customer Customer NO Product Name Piezo Transducer Model Name KPT G2223P8 Drawing No OEM2336R Comp...

Page 2: ...tic com 1 Scope 2 General 3 Maximum Rating 4 Electrical Characteristics 5 Measuring Method 6 Physical Characteristics 7 Environmental Characteristics 8 Dimensions 9 Packaging Standard 10 11 Cautions 1...

Page 3: ...ied to the piezoelectric sounder in alarm systems Please contact us when using this product for any other applications than described in the above 1 Scope Model No Page Revision No Drawing No 3 10 Spe...

Page 4: ...the standard condition Temperature 25 3 Humidity 60 10 R H is regulated measure 25 3 60 10 R H 5 35 45 85 R H piezoelectric sounder 10cm 5 1 S P L Measuring Circuit 5 2 Measuring Condition 5 Measuring...

Page 5: ...XYZ 3 1 5mm 300 5 3 0 5 260 5 10 1 4 Lead terminal are immersed up to 1 5mm from sounder s body in solder bath of 300 5 for 3 0 5 seconds or 260 5 for 10 1 seconds and then sounder shall be measured a...

Page 6: ...nmental Characteristics 7 2 7 1 Item Cold Test Storage Dry Heat Test Storage The measured value shall meet Table 1 1 Specification After being placed in a chamber with 90 to 95 R H at 40 2 for 96 hour...

Page 7: ...e Ningbo Kepo Electronics Co Ltd http www chinaacoustic com 8 Dimensions Model No Page Revision No Drawing No 7 10 Specification for Transducer OEM2336R KPT G2223P8 1 2 FIRST ANGLE PROJECTION UNIT mm...

Page 8: ...ch minimum package unit of products shall be in a carton box and it shall be clearly marked with Part Number quantity and outgoing inspection number There shall be no mechanical damage on products dur...

Page 9: ...something of force such as failing shock and temperature changing 11 2 The component may be damaged if mechanical stress over this specification is applied 11 1 Please contact us before using our prod...

Page 10: ...aacoustic com 12 Revision Specification for Transducer Model No Page Revision No Drawing No 10 10 Rev No DATE PAGE DESCRIPTION SIGN OEM2336R 1 2 KPT G2223P8 2009 04 07 primary 1 0 1 1 2010 04 13 8 Cha...

Reviews: