Specification for Transducer
1.0
S.G. : DF1010
振荡器或等同品
S.G. : DF1010 Oscillater or equivalent
MIC : ND10
普通声级计或等同品
MIC : ND10 S.P.L. or equivalent
Part shall be measured under a condition (Temperature :+5 to +35
℃
,Humidity :45 to
85%R.H.)unless the standard condition (Temperature :+25
±
3
℃
,Humidity :60
±
10
%R.H.) is regulated measure.
温度
+25
±
3
℃,湿度
60
±
10%R.H.
标准测试状态
,
在没有疑问的场合
,
可以在温度
+5
~
+35
℃
,
湿度
45
~
85%R.H.
的范围内测试
.
压电声响器
piezoelectric sounder
10cm
5.1
声压测试线路
S.P.L. Measuring Circuit
5.2
测试环境
Measuring Condition
5.
测试方法
Measuring Method
输入信号
:5Vp-p,1.1KHz,
方波
Input Signal:5Vp-p,1.1KHZ,Square wave
Amp.
Mic.
KP3.840.377R
KPR-G3530
6.
机械性能
Physical Characteristics
实验条件
Test Condition
振动频率
10
~
55 Hz,1.5mm
全振幅
,XYZ
三
个方向
各
2
小时
试验
后
,
测试声响器
.
Sounder shall be measured after being applied
vibration of amplitude of 1.5mm with 10 to55Hz band of
vibration frequency to each of 3 perpendicular directions
for 2 hours.
Sounder shall be measured after being applied
shock(980m/s
2
) for each three mutually
perpendicular directions to each of 3 times by half
sine wave.
峰值加速
度
980m/s
2
,
半正弦
波
,
XYZ
三
个方向
各
3
次冲击
实验
后
,
测试声响器
.
6.2
6.1
Vibration
Resistant
耐
振动性
Shock
耐冲击
性
实验项
目
Item
The measured
value shall meet
Table 1.
符合表
1
的要
求
实验
后规格