Q U I C K   S T A R T   G U I D E

KEPCO

An ISO 9001 Company.

BOP

2X-DE SERIES

BIPOLAR 2X-DE SERIES

DUAL CHANNEL OPERATIONAL POWER SUPPLY

I — INTRODUCTION

1.1.  SCOPE OF MANUAL. 

This Quick Start Guide

covers simple installation and local operation of the Kepco
BOP 2X-DE Series Dual Channel Bipolar Operational
Power Supply, hereafter referred to as BOP 2X-DE. Com-
plete specifications, features and instructions are found in
the full BOP 2X-DE Series Operator Manual that can be
downloaded free from the Kepco web site at:

   

www.kepcopower.com/support/opmanls.htm#bop-op

1.2.  DESCRIPTION. 

Kepco's Series BOP 2X-DE dual-channel BOP models are
200W and 400W power supplies. Each channel is a sepa-
rate power supply, completely isolated, independent and
functionally identical. The 200W units have two 100W
channels and the 400W units have two 200W channels.
The channels are completely isolated, but share two digital
front panel meters (without affecting isolation) which dis-
play d-c output voltage and current for the channel selected
by the front panel Channel select switch. A single power
cord powers both channels; separate on-off circuit breakers
turn each channel on/off separately.

Each BOP 2X-DE channel is a linear stabilizer with two
bipolar control loops (voltage or current mode), selectable
and individually controllable by remote signals applied to
the PC 15 programming connector at the rear panel. These
two principal control loops are each protected by bipolar
limit circuits. The positive and negative current or voltage
limit points can be remotely programmed simultaneously or
Individually. Automatic crossover between each principal
control loop and the limit loops is provided. Only one princi-
ple loop (voltage or current) can control the output at any
one time.

Each channel can operate automatically in all four voltage-
current quadrants; it can act as either a source (output volt-
age is the same polarity as output current) or a sink (output
voltage is opposite the polarity of output current). An exam-
ple is shown in Figure 1 where the BOP channel is pro-
grammed to deliver a sine wave output and the load
produces a phase shift between the output voltage and cur-
rent. See BOP 2X-DE Series Operator Manual (PAR. 1.1)
for limits on long-term operation in sink mode.

Remote On-Off Feature. 

A remote on-off feature provides

Isolated remote on-off control of the output; an associated

flag signal is configured at the PC 15 programming connec-
tor. 

Units are shipped for 115V a-c operation (105V to 125V
a-c), 57 to 63Hz. For operation at 104V a-c, 208V a-c or
230V a-c refer to the full Operator Manual (PAR 1.1).

LAN OPERATION. 

Each channel of the BOP 2X-DE

includes a LAN interface that accepts digital data bus infor-
mation from a computer and converts it to an analog signal
which, in turn, controls the channel output. 

FIGURE 1.  SINK OPERATION PRODUCED BY LOAD 

PHASE SHIFT

1.3.  OPTIONS. 

Models optimized to operate in current

mode with large inductive loads are identified by suffix L.
Models optimized to operate in voltage mode with large
capacitive loads are identified by suffix C.

1.4.  EQUIPMENT SUPPLIED. 

• Two PC 15 programming connectors. One PC 15 

programming connectors 

MUST be

 installed at the 

rear panel of each channel to enable operation.

• 115V a-c Line Cord NEMA 5-15P-C13

1.5.  ACCESSORIES (NOT SUPPLIED) 

• Slides 

Summary of Contents for BOP 2X-DE Series

Page 1: ...olar limit circuits The positive and negative current or voltage limit points can be remotely programmed simultaneously or Individually Automatic crossover between each principal control loop and the...

Page 2: ...INARY CHECKOUT A simple oper ating check after unpacking and before permanent instal lation is advisable to ascertain whether the BOP 2X DE has suffered damage in shipment 1 Install PC 15 programming...

Page 3: ...work reduces noise ripple that may be present at the output when the output is not grounded INPUT A C CONNECTIONS Install the line cord sup plied at the rear panel and connect to 115V a c 60Hz 105V to...

Page 4: ...to run the application A separate window opens as shown in Figure 5 Once the search is completed all found units are displayed in the Select a Unit window the MAC address appears in parentheses If you...

Page 5: ...by default to a fixed value approximately 10 above the nominal output voltage and current of the unit Refer to the Operator s Manual see PAR 1 1 to use external reference signals in the 0 to 10V range...

Page 6: ...nt 1 Refer to PAR 3 4 and connect the load to the DC OUTPUT Terminal Block for the channel in use 2 Perform steps 1 through 9 of the Preliminary Checkout see PAR 3 2 3 Click on the MODE button at the...

Page 7: ...BOP Channel Voltage Limit Series and Parallel Connection of BOP Channels Remote On Off Control The following additional features are covered in the BIT 802E Operator Manual see PAR 1 1 Programming an...

Page 8: ...8 228 1921 022720 KEPCO INC 131 38 SANFORD AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com...

Reviews: