I — DESCRIPTION.

The BOP 2KW-MG/ME Series hereafter referred to as
BOP, are true 4-quadrant programmable voltage and
current power supplies, meaning they are capable of
both sourcing and sinking power (see Figure 1). These
bipolar power supplies pass smoothly through zero
without switching to provide true ± voltage and ± cur-
rent. These BOP power supplies use switch mode
technology for low dissipation. A bi-directional, isolat-
ing, a-c input power factor correcting (PFC) circuit
recuperates energy sinked from an active load and
sends it back into the line to maintain low dissipation.

These BOP power supplies are controlled digitally from
a menu-driven front-panel keypad or one of the remote
digital interfaces (GPIB or RS 232 on MG models, LAN
or RS 232 on ME models) to set voltage and current
and the four protection limits (+voltage, –voltage, +cur-

rent and –current.) A front panel rotary adjuster allows
real-time adjustment of the output. A large LCD dis-
plays the mode of operation, the settings, and the
actual output voltage and current. Additionally, these
BOP models can be remotely controlled by an analog
±10V input for the main channel (voltage or current),
and a +1 to +10V input for the limit channels. 

BOP models are suitable for driving inductive loads
such as large magnets or motors, and for exercising
batteries. They are also suitable for characterizing
solar cell arrays, and powering many electrochemical
reactions. Models with L suffix have been optimized for
exceptionally low current ripple and noise and
improved stability (drift and temperature), making them
ideal for driving inductive loads such as large magnets
or motors.

II — UNPACKING.

This instrument has been thoroughly inspected and
tested prior to packing and is ready for operation. After
careful unpacking, inspect for shipping damage before
attempting to operate. Perform the “Installation.” on

page 5. If any indication of damage is found, file an
immediate claim with the responsible transport service.

.

III — EQUIPMENT SUPPLIED

.

 

None.

IV — SAFETY. 

See Table 2

TABLE 1.  BOP 2KW-MG/ME MODEL PARAMETERS

Model 

(1)

d-c Output Range

Closed Loop Gain

Voltage 

(2)

(V d-c)

Current

(A d-c)

Voltage Channel

G

V

 (V/V)

Current Channel

G

I

 (A/V)

2000 WATT MODELS

BOP 6-250MG/ME

0 to ±6

0 to ±250

0.6

25.0

BOP 10-200MG/ME

0 to ±10

0 to ±200

1.0

20.0

BOP 16-125MG/ME

0 to ±16

0 to ±125

1.6

12.5

BOP 40-50MG/ME

0 to ±40

0 to ±50

4.0

5.0

BOP 50-40MG/ME

0 to ±50

0 to ±40

5.0

4.0

BOP 72-28MG/ME

0 to ±72

0 to ±28

7.2

2.8

BOP 100-20MG/ME

0 to ±100

0 to ±20

10.0

2.0

BOP 144-14MG/ME

0 to ±144

0 to ±14

14.4

1.4

BOP 200-10MG/ME

0 to ±200

0 to ±10

20.0

1.0

(1) Models with MG suffix include GPIB and RS 232 digital interfaces. Models with ME suffix include LAN and RS 232 digital interfaces.
(2)  When connecting active loads, the steady-state voltage of the active load must not exceed the maximum voltage rating of the BOP. Otherwise the overvolt-

age protection will shut down the power supply.

TABLE 2.  SAFETY SYMBOLS

SYMBOL

MEANING

CAUTION: RISK OF ELECTRIC SHOCK.

CAUTION: REFER TO REFERENCED PROCE-
DURE.

WARNING

INDICATES THE POSSIBILITY OF BODILY 
INJURY OR DEATH.

CAUTION

INDICATES THE POSSIBILITY OF EQUIPMENT 
DAMAGE.

!

Summary of Contents for BOP 10-200ME

Page 1: ...ing instructions including an Installation Operation Summary which includes hyperlinked references to detailed procedures but which can be printed as a handy reference The BOP 2KW MG ME Operator s Man...

Page 2: ...ering many electrochemical reactions Models with L suffix have been optimized for exceptionally low current ripple and noise and improved stability drift and temperature making them ideal for driving...

Page 3: ...th displayed voltage on LCD within 0 05 of rated maximum voltage VI ACCESSORIES See Table 3 TABLE 3 ACCESSORIES ITEM FUNCTION PART NUMBER Mating Connector Trigger Mates with Trigger port 142 0527 Kepc...

Page 4: ...4 228 1915 053119 KEPCO INC 131 38 SANFORD AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 1 BOP OUTPUT CHARACTERISTICS...

Page 5: ...Terminal Block Then connect OUT S and COM S lines from the BOP 2KW Sense Monitor Terminal Block to the load see Figure 7B using 22 AWG wire twisted pair ANALOG I O CONNECTIONS The Analog I O Port conn...

Page 6: ...load exists contacts cannot be held closed by actuator When the power supply is turned on it per forms a brief self test that includes testing the three processors analog interface and dis play and an...

Page 7: ...con figuration shown as a power up setting so the changes will not be lost when the unit is turned off APPLY EXIT applies the current changed setting without saving for power up and exits to the previ...

Page 8: ...AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 4 BOP 2KW SERIES POWER BOOST SECTION FRONT PANEL CONTROLS AND INDICATORS FIGURE...

Page 9: ...o incre ment or decrement the highlighted digit Pressing ADJUST while rotating adjusts the least significant digit If the output is on unit not in Standby changes made using the ADJUST control are imm...

Page 10: ...channel is determined by the MODE key in local mode which alternately selects either Voltage mode or Current mode or by SCPI com mand in digital remote mode The protection channel is determined automa...

Page 11: ...l are possible Otherwise the value entered is applied to both positive and negative protect channels NOTE The BOP can be configured to show the protection limits as either a single value that applies...

Page 12: ...loads Table 4 indicates how the power supply responds to a command to go from Output ON to OFF When the output is disabled the unit is set to voltage mode voltage is set to zero and both current prot...

Page 13: ...opened after the connections are complete and then the switch in series with the battery should be closed If the constant voltage type active electronic load is adjusted to zero before handling the p...

Page 14: ...com mands via RS 232 GPIB or LAN ports opera tion via web pages Analog Remote Operation via Analog I O port Details about Protect Limits and Software controlled limits Storing Recalling Power Supply...

Page 15: ...15 15 KEPCO INC 131 38 SANFORD AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 9 BOP 2KW OUTLINE DIMENSIONS Sheet 1 of 2 REAR VI...

Page 16: ...NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 10 BOP 2KW WIRING DIAGRAM DETAIL A S MON OUT OUT MON COM GND GND NET OUT MON N C OUT S COM S CO...

Reviews: