ABC 040104
B-11
Description:
Starts or stops user programmed sequence.
Program sequence is preprogrammed using LIST
commands, starting address is established by LIST:SEQ:STAR. When PROG:SEL:STAT command is
executed the keyboard is locked until the program stops running. *RST command aborts a program
that is running. Related commands: PROG:SEL:STAT?, LIST:CURR, LIST:CURR:PROT, LIST:VOLT,
LIST:VOLT:PROT, LIST:DWEL, LIST:SEQ:NEXT, LIST:SEQ:STAR
B.45
PROGram:SELect:STATe?
QUERY
PROG:SEL:STAT?
Syntax
:
Short Form: PROG:SEL:STAT?
Long Form: PROGram:SELect:STATe?
Return value: <boolean> (0 = stopped, 1 = running)
Description:
Indicates status of user progammed sequence.
1 returned when program is running. 0 returned
when program is stopped. Related commands: PROG:STAT
B.46
READ[:SCALar]:CURRent[:DC]?
QUERY
READ:CURR?
Syntax:
Short Form: READ[:SCAL]:CURR[:DC]?
Long Form: READ[:SCALar]:CURRent[:DC]?
Return Value: <num_value> (digits with decimal point and Exponent)
Description:
Measures actual current.
Same as MEAS:CURR? (see PAR. B.38)
B.47
READ[:VOLTage][:SCALar][:DC]?
QUERY
READ:VOLT?
Syntax:
Short Form: READ[:SCAL]:VOLT[:DC]?
Long Form: READ[:SCALar]:VOLTage[:DC]?
Description:
Measures actual voltage.
Same as MEAS:VOLT? (see PAR. B.39)
B.48
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPlitude]
COMMAND
CURR
Syntax:
Short Form: [SOUR:]CURR[:LEV][:IMM][:AMP] <exp_value>
Long Form: [SOURce:]CURRent[:LEVel][:IMMediate][:AMPlitude] <exp_value>
<exp_value> = digits with decimal point and Exponent, e.g., 2.71E+1 for 27.1
Description:
Sets programmed current level at power supply output.
This command programs output current
to a specific value; actual output current will depend on load conditions. If the value exceeds the max-
imum for the model being programmed, error message -222,”Data out of range” is posted in output
queue. If value programmed exceeds the CURR:LIM:HIGH value, a value corresponding to the cur-
rent limit will be programmed. Related Commands: *RCL, *SAV, CURR:LIM:HIGH. (See example, Fig-
ure B-1.)
B.49
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPlitude]
QUERY
CURR?
Syntax:
Short Form: [SOUR:]CURR[:LEV][:IMM][:AMP]? MIN, MAX
Long Form: [SOURce:]CURRent[:LEVel][:IMMediate][:AMPlitude]? MIN, MAX
Return Value:<exp_value> = digits with decimal point and Exponent, e.g., 2.71E+1 for 27.1
Description:
Returns either the programmed value, maximum value, or minimum value of current.
The
CURR? query returns the programmed value of current. Actual output current will depend on load
conditions. The CURR?MAX query returns the maximum current allowed for a particular model.
CURR? Returns programmed current value. CURR? MAX returns maximum current allowed for
power supply. CURR? MIN returns minimum current allowed for power supply (always 0).
Related
Commands: CURR. (See example, Figure B-1.)
B.50
[SOURce:]CURRent:[:LEVel]TRIGgered[:AMPlitude]
COMMAND
CURR:TRIG
Syntax:
Short Form: [SOUR:]CURR[:LEV]:TRIG[:AMP] <exp_value>
Long Form: [SOURce:]CURRent[:LEVel]:TRIGgered[:AMPlitude] <exp_value>
<exp_value> = digits with decimal point and Exponent, e.g., 2.71E+1 for 27.1
Description:
Programs current value to be transferred to output by *TRG commands.
Actual output current
will depend on load conditions. If the value exceeds the maximum for the model being programmed,
error message -222,”Data out of range” is posted in output queue. If value exceeds CURR:LIM:HIGH
value, a value corresponding to the current limit will be programmed. Related Commands: CURR.
(See example, Figure B-1.)
Summary of Contents for ABC 10-10DM
Page 2: ......
Page 6: ......
Page 14: ...viii ABC 040104 FIGURE 1 1 ABC SERIES POWER SUPPLY...
Page 18: ...1 4 ABCOPR040104 FIGURE 1 1 ABC SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING...
Page 19: ...ABCOPR040104 1 5 FIGURE 1 2 ABC POWER SUPPLY AND RA 71 RACK ADAPTER OUTLINE DRAWING...
Page 20: ...1 6 ABCOPR040104 FIGURE 1 3 TWO ABC POWER SUPPLIES AND RA 72 RACK ADAPTER OUTLINE DRAWING...
Page 24: ......
Page 58: ......
Page 64: ......
Page 94: ......
Page 96: ...FOLD HERE Please place stamp here KEPCO INC 131 38 SANFORD AVE FLUSHING NY 11352 USA CUT HERE...