2

1.1 Safety instructions and warnings 

Only use this display

– in a way according to its intended

purpose

– if its technical condition is perfect

– adhering to the operating 

instructions and the general 

safety instructions.

1.2  General safety instructions

1. Before carrying out any installation or mainte-

nance work, make sure that the power supply

of the digital display is switched off.

2. Only use this digital display in a way according

to its intended purpose:

f its technical condition is perfect.

Adhering to the operating instructions and the

general safety instructions.

3. Adhere to country or user specific regulations.

4. The digital display is not intended for use in

areas with risks of explosion and in the

branches excluded by the standard EN 61010

Part 1.

5. The digital display shall only operated if it has

been correctly mounted in a panel, in accor-

dance with the chapter “Main technical fea-

tures”.

1.4 Description

The 52U 

is a multipurpose device. 

Depending on the programmed basic function, 

the device operates like

• an 

electronic 

totalizer

 and frequency meter

 

(see page 

3

)

• an

 

electronic display counter with 2 

totalizing

 ranges

 

(see page 

5

)

• an

 

electronic 

totalizer

 and time meter

(see page 

7

)

• an

 

electronic time meter with 2 time ranges

 

(see page 

10

)

2. Setting of the operating parameters

a. Press both front side keys keys and switch on

the supply voltage or, if the supply voltage is

already on, press both keys simultaneously

during 5 s.

b. The display shows

c. After releasing the keys, the display shows

c1.Hold the left key pressed and press the right

key to leave the programming operation.

c2.Press the right key to switch to

d. Hold the left key pressed and press the right

key to switch to the first parameter.

1.3 Use according to the intended 

purpose

The digital display may be used only as a panel-

mounted device.  Applications of this product may 

be found in industrial processes and controls, in 

manufacturing lines for the metal, wood, plastics, 

paper, glass, textile and other processing indus-

tries.

Over-voltages at the terminals of the digital dis-

play must be kept within the limits in Category II

If the digital display is used to monitor machines 

or processes in which, in case of a failure of the 

device or an error made by the operator, there 

might be risks of damaging the machine or caus-

ing accidents to the operators, it is your responsi-

bility to take appropriate safety measures.

!

Summary of Contents for 52U

Page 1: ...WARNING Read page 2 first 990146 09 08 20 Electronic display voltage powered dual function counter with 4 functions Model 52U...

Page 2: ...ay counter with 2 totalizing ranges see page 5 an electronic totalizer and time meter see page 7 an electronic time meter with 2 time ranges see page 10 2 Setting of the operating parameters a Press b...

Page 3: ...d the latest values set remaining active They can now be checked again or modified Electronic totalizer and frequency meter 52U basic operating mode 1 Description 6 digit totalizer and frequency meter...

Page 4: ...ng for UB 4 2 Switching on the 30 Hz filter INP A 30 Hz filter off fmax It can be set from 00 0001 up to 99 9999 The decimal point is set to 4 decimal places 0 is not accepted 30 Hzfilter on 4 3 Multi...

Page 5: ...ng via two setting keys on the front side During programming the display guides the user with text prompts 2 Inputs INP A Dynamic count input Counter 1 and Counter 2 RESET Dynamic RESET input Linked i...

Page 6: ...does not affect counting 0 no decimal place 0 0 one decimal place 0 00 two decimal places 0 000 three decimal places 4 5 Decimal point 4 6 RESET mode totalizer 1 manual reset via the red RESET key and...

Page 7: ...operating modes Counting while INP B is inactive GAtE Lo Counting while INP B is active GAtE hi Count Start Stop with INP B edge B Inb Inb Counting ranges h min s h min s 2 Inputs INP A Dynamic count...

Page 8: ...decimal places 0 is not accepted 4 4 Dividing factor totalizer The decimal point defines the way of displaying the count values It does not affect counting 0 no decimal place 0 0 one decimal place 0 0...

Page 9: ...The decimal point defines the resolution of the pro grammed time unit 0 1 0 0 1 10 0 1 0 00 1 100 0 01 0 000 1 1000 0 001 4 11 End of programming The programming routine is repeated once more The val...

Page 10: ...Can be adjusted individually for Counter 1 and Counter 2 3 Selection of the displayed value Pressing the right key allows switching between the display of time meter 1 and the display of time meter 2...

Page 11: ...ectrical reset via the RESET input no reset red RESET key and RESET input locked only electrical reset via the RESET input only manual reset via the red RESET key only electrical reset via the RESET i...

Page 12: ...2 Start InpB InpB and Inp B connected with Inp A at maximum frequency square wave pulses 1 1 Frequency measurement Accuracy 0 1 Measuring principle 38 Hz period measurement 38 Hz gating time measureme...

Page 13: ...nel cut out 50 x 25 mm 1 Bezel for clip mounting panel cut out 50 x 25 mm 1 Seal 1 Operating instructions 6 Terminal assignment 8 Dimensions 1 10 30 V DC 2 0 V GND 3 INP A 4 INP B 5 Reset Panel cut ou...

Page 14: ...KESSLER ELLIS PRODUCTS 10 Industrial Way East Eatontown NJ 07724 800 631 2165 732 649 7100 Fax 732 649 7099 KEP com...