Frequency response : 1 m V ~ 3 0 0 V ranges:
1 0 H z ~ 5 0 0 k H z w i t h i n ± 3 d B
3 0 / A / — 3 0 0 M / ranges:
1 0 H z ~ 1 5 0 k H z w i t h i n ± 3 d B
10
/iV
range:
1 0 H z ~ 3 0 k H z w i t h i n ± 3 d B
D C O U T P U T A M P L I F E R :
Output voltage : 1V±10% f o r f u l l s c a l e
Output resistance : 600O ±10%
Frequency response : A p p r o x the same a s the meter
indication.
[Environmental]
coefficient : 0.08%/°C or less
( a t 1m
V
range or more)
Operating temperature and h u m i d i t y f o r w i t h i n
specification : 15~35°C, 80% R H m a x i m u m .
F u l l operating range : 0~50°C, 80% R H m a x i m u m .
[Power Supply Section]
Supply voltage : 100/117/220/240VAC ±10%
(Max.
2 5 0 V A C ) 50/60Hz
Power consumption : A p p r o x . 15W
[Dimensions]
W i d t h 128mm, Height 190(214)mm
^ Depth 285(315)mm
( ) di nsions include protrusions
f r o m the basic case.
[Weight]
4.6 kg
[Accessories]
Power card 1
Input cable(CA-41) 1
Instruction manual ............ 1