91
APPENDICES
●
1
Sets RX/TX (VFO A/B, memory channel).
FR
2
Parameter Format
Parameter function
P1
3
FUNCTION
3
4
5
6
7
8
9 10 11 12 13 14
Input
Function
Output
Set
Read
Answer
1
2
3
4
5
6
7
8
9 10 11 12 13 14
1
2
3
F
P1 ;
F
P1 ;
F R/T ;
4
5
6
7
8
9 10 11 12 13 14
FT
FUNCTION RX, FUNCTION TX
R/T
R/T
1
Reads status of the transceiver.
IF
INFORMATION
2
Parameter Format
Parameter function
P1
P2
P3
P4
P5
P6
P7
P8
P9
P10
P11
P12
P13
P14
P15
4
–
5
1
1
–
7
11
2
3
1
1
1
14
–
FREQUENCY
NOT USED
RIT/XIT FREQUENCY
RIT OFF/ON
XIT OFF/ON
NOT USED
MEMORY CHANNEL
TX/RX
MODE
FUNCTION
SCAN OFF/ON
SPLIT OFF/ON
TONE OFF/ON
TONE NUMBER
NOT USED
3
4
5
6
7
8
9 10 11 12 13 14
15
Input commands
Function
Output commands
Set
command
Read
command
Answer command
16 17 18 19 20 21 22 23 24 25 26 27 28
1
2
3
I
F
;
4
5
6
7
8
9 10 11 12 13 14
15 16 17 18 19 20 21 22 23 24 25 26 27 28
1
2
3
4
5
6
I
F
P1
7
8
9 10 11 12 13 14
15 16 17 18 19 20 21 22 23 24 25 26 27
P7
P4
P3
28
29 30 31 32 33 34
P8 P9 P10 P11 P12 P13
35
P14
36 37 38
;
39 40 41 42
P5
1
Fine function OFF/ON
FS
FINE STEP
2
Parameter Format
Parameter function
P1
1
FINE OFF/ON
3
4
5
6
7
8
9 10 11 12 13 14
Input
Function
Output
Set
Read
Answer
1
2
3
4
5
6
7
8
9 10 11 12 13 14
1
2
3
F
S P1 ;
F
S P1
;
F
S
;
4
5
6
7
8
9 10 11 12 13 14
1
Sets or reads IF shift. For SSB and AM, sets or reads the low-pass filter
cut-off frequency.
IS
IF SHIFT
Note:
If P2 is positive or zero, P1 can be “+” or “ ”.
Allowable data (in units of Hz):
SSB: 1400, 1600, 1800, 2000, 2200,
2400, 2600, 2800, 3000, 3400, 4600, 6000
AM: 2500, 3000, 4000, 5000, 6000,
7000,
CW: 400~1000 (50 Hz steps)
2
Parameter Format
Parameter function
P1
P2
40
41
IF SHIFT
DIRECTION
IF SHIFT
FREQUENCY
3
4
5
6
7
8
9 10 11 12 13 14
Input
Function
Output
Set
Read
Answer
1
2
3
4
5
6
7
8
9 10 11 12 13 14
1
2
3
I
S P1
P2
;
I
S P1
P2
;
I
S
;
4
5
6
7
8
9 10 11 12 13 14
1
Sets or reads keying speed while using the KY command.
KS
KEYER SPEED
2
Parameter Format
Parameter function
P1
42
KEYER SPEED
3
4
5
6
7
8
9 10 11 12 13 14
Input
Function
Output
Set
Read
Answer
1
2
3
4
5
6
7
8
9 10 11 12 13 14
1
2
3
K
S
P1
;
K
S
;
4
5
6
7
8
9 10 11 12 13 14
P1
K
S
;
1
Sets or reads filter bandwidth. For SSB and AM, sets or reads the
high-pass filter cut-off frequency.
FW FILTER WIDTH
2
Parameter Format
Parameter function
P1
38
FILTER WIDTH
3
4
5
6
7
8
9 10 11 12 13 14
Input
Function
Output
Set
Read
Answer
1
2
3
4
5
6
7
8
9 10 11 12 13 14
1
2
3
F W
P1
;
F W
;
4
5
6
7
8
9 10 11 12 13 14
P1
F W
;
Note:
Allowable data(units of 10 Hz):
SSB:
CW:
FSK:
FM:
AM:
0, 5, 10, 20, 30, 40, 50, 60, 80, 100
5, 10, 20, 40, 60, 100
25, 50, 100, 150
500, 600, 800, 1000, 1200, 1400
0, 10, 20, 50
1
Sets or reads AGC time constant.
GT
AUTO GAIN CONTROL TIME CONSTANT
2
Parameter Format
Parameter function
P1
39
AGC TIME CONSTANT
3
4
5
6
7
8
9 10 11 12 13 14
Input
Function
Output
Set
Read
Answer
1
2
3
4
5
6
7
8
9 10 11 12 13 14
1
2
3
G
T
P1
;
G
T
;
4
5
6
7
8
9 10 11 12 13 14
P1
G
T
;
1
Reads Model number of the transceiver.
ID
IDENTIFICATION
2
Parameter Format
Parameter function
P1
16
MODEL NUMBER
3
4
5
6
7
8
9 10 11 12 13 14
Input
Function
Output
Set
Read
Answer
1
2
3
4
5
6
7
8
9 10 11 12 13 14
1
2
3
I
D
P1
;
I
D
;
4
5
6
7
8
9 10 11 12 13 14
1
Converts input characters into Morse code.
KY
CW KEYING
2
Parameter Format
Parameter function
P1
43
KEYER MESSAGE
KEYER BUFFER
3
4
5
6
7
8
9 10 11 12 13 14
15
Input commands
Function
Output commands
Set
command
Read
command
Answer command
16 17 18 19 20 21 22 23 24 25 26 27 28
1
2
3
4
5
6
7
8
9 10 11 12 13 14
15 16 17 18 19 20 21 22 23 24 25 26 27 28
1
2
3
4
5
6
K
P1
7
8
9 10 11 12 13 14
15 16 17 18 19 20 21 22 23 24 25 26 27 28
29 30 31 32 33 34
P2
35 36 37 38 39 40 41 42
;
;
;
K
K
Y
Y
Y
P2
44
Note:
The Set command requires a " " (ASCII
code 20h) in the third byte position.
Insert " " for bytes that have no
characters to make a 28-byte fixed length
command.
The " " bytes will not send any character.
Supported characters include: Letters,
numbers, " ' (( )) ( )
+
,
–
. / : = ?
The internal buffer allows approximately
5 times 28 characters (~140 characters) to be
continuously keyed. For programs that
convert to Morse code immediately after entry,
more continuous keying is possible
Ex
:
CQ CQ CQ DE WD6DJY WD6DJY WD6DJY K
KY_CQ_CQ_ CQ_DE_ WD6DJY_ WD6DJ;
KY_Y_ WD6DJY_K_______________ ;
Summary of Contents for TS-870S
Page 104: ......