TK-8180/8189
46
Item
Condition
Measurement
Adjustment
Specifications/Remarks
Test-
equipment
Unit
Terminal
Parts
Unit
Method
ADJUSTMENT
11. Max DEV
1) Adj item : [n DEV]
Power meter Rear
ANT
Front
[ ],[ ] 2.10kHz
±
0.10kHz
adjust
Adjust : [
✳✳✳
]
panel
panel
(According to the
AG : 1kHz/50mV at MIC terminal
, –)
Deviation meter filter
Deviation
Front
Modular
LPF : 15kHz
meter
panel
MIC jack
HPF : OFF
Oscilloscope
• Narrow
2) Adj item : [nL DEV]
→
AG
[nC DEV]
→
[nH DEV]
AF VTVM
Adjust : [
✳✳✳
]
PTT : ON
• Wide 4k
3) Adj item : [s DEV]
3.30kHz
±
0.10kHz
Adjust : [
✳✳✳
]
(According to the
PTT : ON
, –)
• Wide 5k
4) Adj item : [w DEV]
4.20kHz
±
0.10kHz
Adjust : [
✳✳✳
]
(According to the
PTT : ON
, –)
12. MIC
[Panel test mode]
Check
2.5~3.5kHz
sensitivity
1) CH-Sig : 1-1
check
AG : 1kHz/5mV at MIC terminal
(Wide 5k only)
PTT : ON
13. QT deviation 1) Adj item : [n QT]
Front
[ ],[ ] 0.35kHz
±
0.05kHz
adjust
Adjust : [
✳✳✳
]
panel
Deviation meter filter
LPF : 3kHz
HPF : OFF
• Narrow
2) Adj item : [nL QT]
→
[nC QT]
→
[nH QT]
Adjust : [
✳✳✳
]
PTT : ON
• Wide 4k
3) Adj item : [s QT]
0.60kHz
±
0.10kHz
Adjust : [
✳✳✳
]
PTT : ON
• Wide 5k
4) Adj item : [w QT]
0.75kHz
±
0.10kHz
Adjust : [
✳✳✳
]
PTT : ON
14. DQT
1) Adj item : [n DQT]
0.35kHz
±
0.05kHz
deviation
Adjust : [
✳✳✳
]
adjust
Deviation meter filter
LPF : 3kHz
HPF : OFF
• Narrow
2) Adj item : [nL DQT]
→
[nC DQT]
→
[nH DQT]
Adjust : [
✳✳✳
]
PTT : ON
• Wide 4k
3) Adj item : [s DQT]
0.60kHz
±
0.10kHz
Adjust : [
✳✳✳
]
PTT : ON
• Wide 5k
4) Adj item : [w DQT]
0.75kHz
±
0.10kHz
Adjust : [
✳✳✳
]
PTT : ON