52
TK-780/H
ADJUSTMENT
Adjustment Location
■
Switch
MODULAR
MIC JACK
MONITOR
SCAN
POWER
BUSY/
TX LED
VOLUME
UP
VOLUME
DOWN
SYSTEM UP
(Trunking Format)
GROUP UP
(Conventional Format)
SYSTEM DOWN
(Trunking Format)
GROUP DOWN
(Conventional Format)
SUB
DISPLAY
MONITOR
PRIORITY
SERVICE
AUXILIAY
HANDSET
SCAN
PROGRAMMABLE
FUNCTION KEYS
ALPHANUMERIC
DISPLAY
■
Adjustment Point
■
Note
• Flash memory
The firmware program (User mode, Test mode, Tuning
mode, etc.) and the data programmed by the FPU (KPG-49D)
for the flash memory, is stored in memory. When parts are
changed, program the data again.
• EEPROM
The tuning data (Deviation, Squelch, etc.) for the
EEPROM, is stored in memory. When parts are changed,
readjust the transceiver.
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
1. PLL lock
1) Set test mode
DVM
TX-RX
TP1
PLL
TC101 1.5V
±
0.1V
voltage
CH : CH3 - Sig1
Power meter (A/2)
AUX : ON (Talk-around mode) F. conter
TC102 1.5V
PTT : ON (Transmit)
2) CH : CH2 - Sig1
Check
8.0V or less
PTT : ON (Transmit)
Common Section
Repair Jig (Chassis)
Use jig (Part No. : A10-4010-02) for repairing the TK-780/
780H. The jig facilitates the voltage check when the voltage
on the component side TX-RX unit (A/2) is checked during
repairs.
L6
VR1
TX-RX UNIT (A/2)
PLL/VCO
TC101
TC1
TC102
TP1