TK-7150
42
Item
Condition
Measurement
Adjustment
Specifications/Remarks
Test-
equipment
Unit
Terminal
Parts
Unit
Method
ADJUSTMENT
14. DQT
1) CH-SIG : 1-7
Power meter Rear
ANT
Front
Selector
±
0.75kHz
±
0.05kHz
deviation
Select DQT_Dev_ _
✽✽✽
Deviation
panel
panel
knob
• Wide
in tuning mode
meter
PTT : ON
Deviation meter filter
AF VTVM
Front
MIC
HPF : OFF
AG
panel
LPF : 3kHz
Oscilloscope
De-emphasis : OFF
• Narrow
2) [PF5] key : Set the narrow
±
0.35kHz
±
0.05kHz
n_ _
DQT_Dev_ _
✽✽✽
in tuning mode
PTT : ON
15. LTR code
1) CH-SIG : 1-2
1.00kHz
±
0.05kHz
deviation
Select LTR_Dev_ _
✽✽✽
• Wide
in tuning mode
PTT : ON
Deviation meter filter
HPF : OFF
LPF : 3kHz
De-emphasis : OFF
• Narrow
2) [PF5] key : Set the narrow
0.75kHz
±
0.05kHz
n_ _
LTR_Dev_ _
✽✽✽
in tuning mode
PTT : ON
16. DTMF
1) CH-SIG : 1-9
±
3.0kHz
±
0.1kHz
deviation
Select DTMF_Dev_
✽✽✽
• Wide
in tuning mode
PTT : ON
Deviation meter filter
HPF : OFF
LPF : 15kHz
De-emphasis : OFF
• Narrow
2) [PF5] key : Set the narrow
±
1.5kHz
±
0.1kHz
n_ _
DTMF_Dev_
✽✽✽
in tuning mode
PTT : ON
17. MSK
1) CH-SIG : 1-12
±
3.0kHz
±
0.1kHz
deviation
Select MSK_Dev_ _
✽✽✽
• Wide
in tuning mode
PTT : ON
Deviation meter filter
HPF : OFF
LPF : 15kHz
De-emphasis : OFF
• Narrow
2) [PF5] key : Set the narrow
±
1.5kHz
±
0.05kHz
n_ _
MSK_Dev_ _
✽✽✽
in tuning mode
PTT : ON