35
TK-6110
Test Equipment Required for Alignment
No.
Test Equipment
Major Specifications
1
Standard Signal Generator
Frequency Range
50kHz to 1000MHz.
(SSG)
Modulation
Frequency modulation and external modulation.
Output
0.1
µ
V to greater than 1mV.
2
Power Meter
Input Impedance
50
Ω
.
Operation Frequency
50MHz or less.
Measurement Capability
Vicinity of 100W.
3
Deviation Meter
Frequency Range
29.7 to 50.0MHz.
4
Digital Volt Meter
Measuring Range
1 to 20V DC.
(DVM)
Accuracy
High input impedance for minimum circuit loading.
5
Oscilloscope
DC through 30MHz.
6
High sensitivity
Frequency Range
10Hz to 200MHz.
Frequency Counter
Frequency Stability
0.2ppm or less.
7
Ammeter
30A.
8
AF Volt Meter
Frequency Range
50Hz to 10kHz.
(AFVTVM)
Voltage Range
3mV to 3V.
9
Audio Generator (AG)
Frequency Range
50Hz to 5kHz or more.
Output
0 to 1V.
10
Distortion Meter
Capability
3% or less at 1kHz.
Input Level
50mV to 10Vrms.
11
Voltmeter
Measuring Range
10 to 1.5V DC or less.
Input Impedance
50k
Ω
/V or greater.
12
4
Ω
Dummy Load
Approx. 4
Ω
30W.
13
Regulated Power Supply
(Adjustable from 9 to 17V, 30A).
Useful if ammeter equipped.
Caution
Since the RX AF output is a BTL output, there is a DC
Component. Isolate this with a capacitor or transformer as
shown in the figure.
ADJUSTMENT
Lead wire +
MIC
Shiel wire –
1
8
Tuning cable (E30-3383-05)
Adapter cable (E30-3383-05) is required for
injecting an audio if PC tuning is used.
See “PC Mode” section for the connection.
MIC connector
(Front view)
1 : BLC
2 : PSB
3 : E
4 : PTT
5 : ME
6 : MIC
7 : HOOK
8 : CM
Test cable for microphone input (E30-3360-08)
Test cable for speaker output