TK-361SA
4
4-5. Programming Software Description
The KPG-88D(M2) is the programming software for the
transceiver supplied on a CD-ROM. The software on this
disk allows a user to program the transceiver radios via Pro-
gramming interface cable (KPG-22/22A).
4-6. Programming with PC
If data is transferred to the transceiver from a PC with
the KPG-88D(M2), the data for each set can be modifi ed.
Data can be programmed into the EEPROM in RS-232C
format via the SP/MIC jack.
In this mode the PTT line operate as TXD and RXD data
lines respectively.
PC
KPG-22 or KPG-22A or
KPG-22A+KCT-53U
Illustration is KPG-22
KPG-88D(M2)
Tuning cable
(E30-3216-05)
D-SUB
(25-pin)
Transceiver
KPG-22
PC
Gray
Gray/Black
1.5D-XV Lead wire
1.5D-XV Shield wire
+
–
+
–
SP
MIC
D-SUB
(9-pin)
Transceiver
KPG-22A
PC
USB
Transceiver
KPG-22A
KCT-53U
PC
Fig. 1
5. Clone Mode
5-1. Outline
“Clone Mode” copies the transceiver data to another
transceiver.
The dealer can copy the transceiver data to another
transceiver even without the use of a personal computer.
5-2. Example
The transceiver can copy the programming data to one
or more transceivers via RF communication.
The clone source and clone target/s must be in Clone
mode.
5-3. Operation
1. To switch the clone target/s to Clone mode, press and
hold the [PTT] and [Side2] keys while turning the trans-
ceiver power ON.
2. Wait for 2 seconds. The LED will light orange and the
transceiver will announce “Clone”.
3. Select a channel table number using Lock (increment
channel table) and Scan(decrement channnel table) keys.
4. To switch the clone source to Clone mode, press and
hold the [PTT] and [Side2] keys while turning the trans-
ceiver power ON.
5. Wait for 2 seconds. The LED will light orange and the
transceiver will announce “Clone”.
6. Select the same channel table number as the clone tar-
get/s.
7. Press [PTT] on the clone source to begin data transmis-
sion.
When the clone target starts to receive data, the LED
will light green.
When the clone source fi nishes sending data, a “confi r-
mation” tone will sound.
If data transmission fails while cloning, an “error” tone
will sound from the target unit.
8. If the cloning fails, no data will be available in the target
unit when it is returned to User mode.
9. When the cloning is successful, the target unit’s “Scan”
function will return to their default values (Scan = OFF).
Notes:
• The dealer can clone data to two or more transceivers by
repeating the above procedures.
• If the transceivers Clone Mode is configured as “Dis-
abled”, the transceiver cannot enter Clone mode.
• The table shown below will cover the frequency tables
used for wireless cloning.
• Clone mode cannot be entered in battery low state.
• A unit cannot be a “Source Unit” if it is unprogrammed.
If [PTT] is pressed, an “error” tone will sound.
• Once a unit is set to be the source, it cannot be a target
after the data has been transmitted. This protects the
data in the source unit.
• If the target unit is cloned successfully, it will return to
User Mode.
• If the target unit is not cloned successfully, the led will
remain Orange.
REALIGNMENT