25
L
AMP
The lamp is used to illuminate the Liquid Crystal Display. You
can set the lamp to remain off, remain on, or turn on when
you press any key other than the
PTT
switch (auto). When set
to auto, the lamp remains on for 5 seconds after pressing a
key before turning off again.
To select the lamp setting:
T
IME
-
OUT
T
IMER
The purpose of the Time-out Timer is to prevent you from
using a channel for a long time. This function is useful, for
example, when you accidentally keep the
PTT
switch pressed.
Additionally, by limiting the amount of time you can
1
Turn the transceiver power OFF.
2
Press and hold the
MENU
key while turning
the transceiver power ON (for 1 second).
3
Press the
▲
or
▼
key to select “
”.
4
Press the
MENU
key to select “
” (lamp
off), “
” (lamp on), or “
” (lamp auto).
5
Press the
PTT
,
MON
, or
CAL
key to exit
Setting Mode.