Frequency and Signaling
The transceiver has been adjusted for the frequencies
shown in the following table. When required, re-adjust them
following the adjustment procedure to obtain the frequen-
cies you want in actual operation.
■
Frequency (MHz)
Channel No.
RX Frequency
TX Frequency
1
155.050
155.100
2
136.050
136.100
3
173.950
173.900
4
155.000
155.000
5
155.200
155.200
6
155.400
155.400
7~16
-
-
■
Signaling
Signaling No.
RX
TX
1
None
None
2
None
100Hz Square Wave
3
QT 67.0Hz
QT 67.0Hz
4
QT 151.4Hz
QT 151.4Hz
5
QT 250.3Hz
QT 250.3Hz
6
DQT D023N
DQT D023N
7
DQT D754I
DQT D754I
8
DTMF Decode [159D]
DTMF Encode [159D]
9
None
DTMF Tone 9
Preparations for Tuning the Transceiver
Before attempting to tune the transceiver, connect the
unit to a suitable power supply.
Whenever the transmitter is tuned, the unit must be con-
nected to a suitable dummy load (i.e. power meter).
The speaker output connector must be terminated with a
8
Ω
dummy load and connected to an AC voltmeter and an
audio distortion meter or a SINAD measurement meter at all
times during tuning.
■
Adjustment frequency
TEST CH
RX
TX
Center
155.050MHz
155.100MHz
Low
136.050MHz
136.100MHz
High
173.950MHz
173.900MHz
Low’
145.550MHz
145.600MHz
High’
164.550MHz
164.600MHz
■
List of FPU for transceiver
Model
Type
FPU
TK-2302
K,M
KPG-118D(K)
TK-2302
P
KPG-119D(K)
TK-2302(V)
K
KPG-119D(K)
TK-2306
M
KPG-118D(M)
ADJUSTMENT
Fig. 1 Center frequency
Fig. 2 High-edge frequency