5
TK-2212L
5. Self Programming Mode
Write mode for frequency data and signaling, etc. To be
used ONLY by the authorized service person maintaining the
user's equipment. After programming, reset the FPU to the
"Self- Programming" disabled mode. Transceivers CANNOT be
delivered to the end-user in the self-programming mode.
REALIGNMENT
Is Data
password
set?
"CLN.LOCK.R”/“CLN.LOCK.W”
is displayed.
Yes
Yes
[S]
No
No
Enter the password and
then press the [S] key.
Is password
correct?
Start the clone function
Clone mode
[<B]+Power ON
■
Flow Chart (Source transceiver)
4-4. Adding the Data Password
If the Data password is set to the transceiver, you must
enter the password to activate a clone mode. The maximum
length of the password is 6 digits.
The following describes how to enter the password.
1. Press and hold the [S] key for 2 seconds while turning the
transceiver power on.
2. “CLN.LOCK.R”(When the Read authorization password is
set to the transceiver.) / “CLN.LOCK.W” (When the
Overwrite password is set to the transceiver.) is displayed
on the LCD.
3. If the [selector] knob is rotated while “CLN.LOCK.R”/
“CLN.LOCK.W” is displayed, the number (0 to 9) flashes
on the LCD.
When you press the [C>] key, the currently selected
number is determined.
If you press the [A] key, the least digit of the password is
deleted.
If you press the [S] key after entering the password in this
procedure, “FRQTBL 1” is displayed if the entered
password is correct.
I f t h e p a s s w o r d i s i n c o r r e c t , “ C L N . L O C K . R ” /
“CLN.LOCK.W” is redisplayed.
5-1. Enter to the Self Programming Mode
Press and hold the [S] key for 2 seconds while turning the
transceiver power on.
When the transceiver enters in the self programming mode,
"1- 1" is displayed 2 seconds after "SELF " is displayed.
Note :
This mode (self programming mode) cannot be set when it
has been disabled with the FPU.
5-2. Adding the Data Password
If the Data password is set to the transceiver, you must
enter the password to activate a self programming mode. The
maximum length of the password is 6 digits.
The following describes how to enter the password.
1. Press and hold the [S] key for 2 seconds while turning the
transceiver power on.
2. "SLF.LOCK.R"(When the Read authorization password is
set to the transceiver.) / "SLF.LOCK.W" (When the
Overwrite password is set to the transceiver.) is displayed
on the LCD.
3. If the [selector] knob is rotated while "SLF.LOCK.R"/
"SLF.LOCK.W" is displayed, the number (0 to 9) flashes on
the LCD.
When you press the [C>] key, the currently selected
number is determined.
If you press the [A] key, the least digit of the password is
deleted.
If you press the [S] key after entering the password in this
procedure, "SELF" is displayed if the entered password is
correct.
If the password is incorrect, "SLF.LOCK.R"/ "SLF.LOCK.W"
is redisplayed.
5-3. Channel Selection Mode
In this mode, the Zone or Channel can be selected.
Press and hold the [S] key for 2 seconds while turning the
transceiver power on to enter self programming mode. When
the transceiver enters in the self programming mode, the
transceiver automatically enters the Channel Selection mode.
2 seconds after displaying "SELF", "1- 1" appears on the LCD.
The setup item for channel selection mode is as follows.
Setup item
Display
Remarks
Select
∗∗∗
-
∗∗∗
Zone:
1~128
Zone/Channel
∗∗∗
-
∗∗∗
Channel: 1~128