30
SELECTING A SCAN RESUME METHOD
The transceiver stops scanning at a frequency or Memory channel on which a
signal is detected. It then continues scanning according to which resume mode
you have selected. You can choose one of the following modes. The default is
Time-operated mode.
TO
Time Operated
mode
The transceiver remains on a busy frequency or
Memory channel for approximately 5 seconds, and
then continues to scan even if the signal is still
present.
CO
Carrier Operated
mode
The transceiver remains on a busy frequency or
Memory channel until the signal drops out. There is
a 2 second delay between signal drop-out and scan
resumption.
SEEK
Seek mode
The transceiver remains on a busy frequency or
Memory channel even after the signal drops out and
does not automatically resume scanning.
1
Enter Menu mode and access Menu No. 14 (RESUME
), then press
[F]
.
2
Rotate the
ENC control
to select a Scan Resume mode from “TO”, “CO” or
“SEEK”, then press
[F]
to store the setting.
3
Press
[MENU]
or
[PTT]
to exit Menu mode.
Summary of Contents for TH-K40A