ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations / Remarks
Test-
equipment
Unit
Terminal
Unit
Parts
Method
5. Power
Check
[13.8V]
DC-IN
4) Power: LOW
Frequency:
144.100MHz
Transmission
Power
meter
Ammeter
ANT
Check
0.2W~0.8W
0.8A or less
5) Power: LOW
Frequency:
147.900MHz
K
145.900MHz
E
Transmission
6) Power: EL
Frequency:
144.100MHz
Transmission
10mW or more
0.5A or less
7) Power: EL
Frequency:
147.900MHz
K
145.900MHz
E
Transmission
8) Power: HI
Frequency:
444.100MHz
K
435.100MHz
E
Transmission
4.5W~5.5W
1.8A or less
9) Power: HI
Frequency:
438.100MHz
K
430.100MHz
E
Transmission
10) Power: HI
Frequency:
449.900MHz
K
439.900MHz
E
Transmission
11) Power: LOW
Frequency:
438.100MHz
K
430.100MHz
E
Transmission
0.2W~0.8W
0.8A or less
12) Power: LOW
Frequency:
449.900MHz
K
439.900MHz
E
Transmission
13) Power: EL
Frequency:
438.100MHz
K
430.100MHz
E
Transmission
10mW or more
0.5A or less
14) Power: EL
Frequency:
449.900MHz
K
439.900MHz
E
Transmission
6. MAX Devia-
tion
Switch to Service Setup mode
and carry out the operations for
item G.
1) Frequency: 146.100MHz
K
145.100MHz
E
AG:
1kHz/80mV
Linear detector (FM±)
LPF:
15kHz
HPF:
OFF
De-emphasis:
OFF
Transmission
Oscillo-
scope
Linear
detector
Power
meter
AG
ANT
Tuning
control
[
X
]
Write
4.2kHz±100Hz
2) Frequency: 136.100MHz
Transmission
3) Frequency: 173.900MHz
Transmission