RXD-M33/M33MD
5
CIRCUIT DESCRIPTION
KEYS
DISPLAY
OPERATION
• 4 Seconds Recording
TAPE REC
If the REC/ARM key is pressed, the system record for 4 seconds.
(RXD-M33MD)
Then, it rewinds to the REC starting position and plays back automatically.
TAPE
If the REC/ARM key is pressed, during the 4 seconds REC operation, the
TAPE O.T.E.
system records further for 4 seconds, then returns to the starting position of
(RXD-M33)
the first 4 seconds REC operation and plays back.
SOUND
Beat-C ON
Beat cancel will be on while pressing the sound key.
MENU
Normal Indication
Changeover the EQ. On/off cyclically.
TEST MODE
SETTING METHOD
CD MODE
CD PLAY key+AC ON
MD MODE (M33MD only)
MD PLAY Key + AC ON
DECK MODE
TAPE PLAY key + AC ON (RXD-M33MD)
TAPE FWD PLAY + AC ON (RXD-M33)
SUB CLOCK OSC
STOP key + AC ON
DIAGNOSIS
KEYS
DISPLAY
OPERATION
CD-PLAY/PAUSE
05
:
Tracking-servo on.
(
:
)Time Display
(Cyclically changed the mode
03
:
Tracking-servo off.
05 and 03 by pressing the key.)
(
:
)Time Display
CD STOP
01 --:--
Stop the CD operation.
Adjustment value/mean value
(Cyclically changed in the
07 FG/FE
FG value /FE value
stop mode only.)
08 FB/FO
FBAL value /FO value
09 TG/TE
TG value /TE value
10 TB/TO
TBAL value /TO value
SKIP UP
Ex.01~02
• Track number up.
SKIP DOWN
Ex.02~01
• Track number down.
SKIP UP
Usual Indication
• Play the first track number in the stop mode.
SKIP DOWN
Usual Indication
• Play the last track number in the stop mode.
• CD FF search.
REPEAT
FF
• The pickup travels outward in the stop mode.
• CD FB search.
SOUND
FB
• The pickup travels inward in the stop mode.
5. Test Mode
5-1 Setting method of the Test Mode
• While pressing the "below each" key in the table, turn the power switch on.
The oscillation diagnosis (existence of oscillation and measurement of period) of a sub clock is performed before the test
mode is entered. If the diagnosis result is OK, the system enters the test mode.
If the diagnosis result is NG, the oscillation of the sub clock is diagnosed again. If the result is OK, the system enters the test
mode. If the diagnosis result is continuously NG 5 times, the system stops with "ERR1" and "ERR2" displayed.
5-2 Cancel of the test mode
• By turning the AC off, the system is initialized and the test mode is canceled.
• Cancel the test mode only if the power switch is turned off.
5-3 Contents of the Test Mode
• The muting during mode selection is not controlled in the test mode.
• During the test mode, it can be operated in a special manner that is different from an ordinary operation by using the keys
on the main body, specifically as shown in the following tables.
5-4 CD Test Mode
5-5 Deck Test Mode