A
C
E
G
I
B
D
F
H
J
2
1
3
5
7
4
6
0.6V
2.3V
2.3V (0V)
1.3V
1.3V
4V
(2.2V)
0V (0.9V)
5V
2.5V
2.1V (2.7V)
2.1V (2.7V)
2.1V
(1.2V)
3.8V
(1.9V)
3.8V
(4.3V)
2.9V
0V
0V
5V
5V
5V
5V
2.1V
2.1V
2.1V
5.2V
5.2V
5.2V
0V
1.5V
1.5V
0.8V
3.8V
4.4V
0V
(0V)
3.7V
4.7V
(0V)
3.9V
(0V)
(0V)
3.5V
0V
0V
0V
3.7V
(11.4V)
1.7V
5.1V
4.8V
0.1V
0.1V
2.6V
0V
2.6V
0.9V
0.9V
5.2V
2.6V
(2.6V)
0V
0V
(0V)
10.8V
10.9V
11.7V
+B
+B
+B
+B
+B
+B
+B
+B
FM IF DET/
FM MPX/AM IF
FM FRONT END
PLL(TUNER)
AM IF
FM IF
FM RF
FM
Band
Coverage
FM ANT.
FM OSC.
1
2
3
1
2
3
1
2
3
10
11
1
2
3
4
5
8
9
6
7
SD
FM ST
DO
CL
CE
DI
A_12V
D_GND
TUN_L
TUN_R
A_GND
VSM
AM RF
OUT
OUT
OUT
OUT
IN
IN
CUT
AM LOW
FM/AM
MPX VCO
MPX IN
MO/ST
L-CH
R-CH
FM AFC
AM OSC
AM OSC
(AM/FM)
PHASE
PHASE
IF OUT
VCC
FM DET
STEREO
SD
GND
AM IF
REG
AM MIX OUT
IN
IN
FM IF
1
1
2
3
4
5
6
7
8
9
2
3
11
10
9
8
7
6
5
4
3
2
1
PD
IF IN
AM IN
FM IN
VDD
AIN
AOUT
VSS
X OUT
22 21 20
19
18
17 16 15
14 13 12
AM SIGNAL
FM SIGNAL
CNP307
TO
MAIN PWB-A1(1/2)
TUNER PWB-A2
FM
FM
MUTE
CE
DI
CL
DO
MO/ST
IF REQ
X IN
23
22
21
20
19
18
17
16
15
14
24
13
12
11
10
9
8
7
6
5
4
3
2
1
AM
GND
FM
75ohms
TP301
CHASSIS
GND
FM Mute
Level
AM Band
Coverage
AM
Tracking
ANTENNA
TERMINAL
BAND PASS
FILTER
4.5MHz
456kHz
2
3
1
C367
1/50
R350
2.7K
SO301
C360
0.022
C362
3.3/50
CNS307
C349
0.001
R366
2.2K
C372
1/50
C371
1/50
C398
100/10
C380
10/16
D308
1N4148
D306
1N4148
D305
1N4148
BF301
C351
0.022
R351
5.6K
VR351
10K(B)
L353
1mH
C319
18P(CH)
C316
10/16
C315
100P
C318
5P
C303
0.001
C312
33P
T304
C304
0.01
C314
22P
(CH)
R310
4.7K
R305
680
R308
10K
R304
47K
R301
22
CF303
R309
470
R313
680
R314
33
R302
100K
Q306
2SC535 C
Q302
2SC535 C
R323
68K
C334
27P(UJ)
C335
560P
C337
0.022
T306
C329
0.022
C331
0.047
C332
0.022
C391
47/16
X351
R361
5.6K
C368
1/50
R356
1K
R357
470K
TP302
R362
5.6K
C369
56P
C374
0.018
C373
0.018
C366
0.001
IC302
LC72131
IC303
LA1832S
IC301
TA7358AP
C302
0.001
CF302
D301
1N4148
D302
1N4148
C330
12P(CH)
T302
R353
270
T351
CF352
C350
0.022
C352
10/16
R352
1K
C353
0.022
C354
0.022
CF351
C363
0.022
C364
10/16
C365
0.022
R358
8.2K
C343
33P
C361
0.022
R382
330
C394
47/16
C397
0.022
C317
0.022
C313
6P(UJ)
C311
10P(CH)
C306
7P(UJ)
C305
0.0047
C307
0.0047
C308
0.022
C309
0.001
C310
0.022
R386
330
R316
330
R312
2.2K
R307
47
R306
10
R303
33K
R315
33
R381
10K
C393
1/50
R380
1.5K
R379
2.2K
C392
0.001
C387
0.022
C385
0.01
R377
5.6K
R355
3.3K
C357
2.2/50
C358
1/50
C399
0.022
C356
0.001
R393
1K
R395
47K
L351
100
µ
H
C370
1/50
C355
22P
C383
0.022
R387
5.6K
L352
100
µ
H
C395
0.022
C396
100/10
ZD351
DZ5.1BSB
R391
390
R392
390
Q351
KRC104 M
R363
3.3K
R364
3.3K
C386
330P
R365
10K
X352
C381
12P(CH)
C382
15P(CH)
R374
1K
R373
1K
R372
1K
R371
1K
R359
1.8K
R360
4.7K
C384
0.001
Q360
KTA1266 GR
R385
5.6K
R384
6.8K
R383
5.6K
R376
10K
R336
5.6K
C301
0.012
VD301
SVC348S
VD302
KDV147C
L303
L302
VD303
KDV147C
N - 1
Y39-4120-21
RD-M23
CAUTION:
For continued safety,
replace safety critical components only
with manufacturer's recommended
parts (refer to parts list).
indicates
safety critical components. For contin-
ued protection against risk of fire,
replace only with same type and rating
fuse(s). To reduce the risk of electric
shock, leakage-current or resistance
measurements shall be carried out
(exposed parts are acceptably insulat-
ed from the supply circuit) before the
appliance is returned to the customer.
The DC voltage is an actual reading measured with a high impedance type volt-
meter as the AM/FM signal generator is specified to the conditions as shown in the
list below. The measurement value may vary depending on the measuring instru-
ments used or on the product. The value shown in ( ) is actual reading measured
in the AM mode.
MODE
CARRIER
MODULATION
ANT INPUT
FREQUENCY
DEVIATION
FM
98MHz
1kHz
STEREO 67.5kHz 7.5kHz(Pilot)
60dB
AM
1000(999)kHz
400Hz
MONO 30% MOD
60dB