![background image](http://html.mh-extra.com/html/kenwood/nx-420-k/nx-420-k_service-manual_191397046.webp)
NX-420
46
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations /
Remarks
Panel tuning mode
PC test mode
Test-
equipment
Unit
Terminal
Unit
Parts
Method
7. DQT
Deviation
*
4
[Narrow]
1) Adj item: [DQT]
Adjust:
[
.]
2) Adj item: [D.Q.T._._.]
[D.Q.T._._.](TA)
Deviation
meter
LPF: 3kHz
HPF: OFF
PTT:
ON
Press
[
] key to
store the adjust-
ment value.
1) Adj item: [DQT Devia-
tion (Analog Narrow)]
2) Adj item: [Hight],
[Hight](TA)
Deviation
meter
LPF: 3kHz
HPF: OFF
PTT:
Press
[Transmit]
button.
Press [Apply] button
to store the adjust-
ment value.
Deviation
meter
Oscilloscope
Panel
ANT
Panel
[Panel
tuning
mode]
Selector
[PC test
mode]
[ ],[ ]
Write the value as
followings.
430 (Reference
value)
0.35kHz±0.05kHz
[Wide 4k]
1) Adj item: [DQT]
Adjust:
[
.
.]
2) Adj item: [D.Q.T._._.]
[D.Q.T._._.](TA)
PTT:
ON
Press
[
] key to
store the adjust-
ment value.
1) Adj item: [DQT Devia-
tion (Analog Wide 4k)]
2) Adj item: [Hight],
[Hight](TA)
PTT:
Press
[Transmit]
button.
Press [Apply] button
to store the adjust-
ment value.
0.60kHz±0.05kHz
[Wide 5k]
1) Adj item: [DQT]
Adjust:
[
.
.
.]
2) Adj item: [D.Q.T._._.]
[D.Q.T._._.](TA)
PTT:
ON
Press
[
] key to
store the adjust-
ment value.
1) Adj item: [DQT Devia-
tion (Analog Wide 5k)]
2) Adj item: [Hight],
[Hight](TA)
PTT:
Press
[Transmit]
button.
Press [Apply] button
to store the adjust-
ment value.
0.75kHz±0.05kHz
8. LTR
Deviation
*
4
[Narrow]
1) Adj item: [LTR]
Adjust:
[
.]
2) Adj item: [L.T.R._._.]
[L.T.R._._.](TA)
Deviation
meter
LPF: 3kHz
HPF: OFF
PTT:
ON
Press
[
] key to
store the adjust-
ment value.
1) Adj item: [LTR Devia-
tion (Analog Narrow)]
2) Adj item: [Hight],
[Hight](TA)
Deviation
meter
LPF: 3kHz
HPF: OFF
PTT:
Press
[Transmit]
button.
Press [Apply] button
to store the adjust-
ment value.
Write the value as
followings.
465 (Reference
value)
0.75kHz±0.05kHz
[Wide 4k]
1) Adj item: [LTR]
2) Adj item: [L.T.R._._.]
[L.T.R._._.](TA)
Adjust:
[
.
.]
PTT:
ON
Press
[
] key to
store the adjust-
ment value.
1) Adj item: [LTR Devia-
tion (Analog Wide 4k)]
2) Adj item: [Hight],
[Hight](TA)
PTT:
Press
[Transmit]
button.
Press [Apply] button
to store the adjust-
ment value.
0.
9
0kHz±0.05kHz
[Wide 5k]
1) Adj item: [LTR]
2) Adj item: [L.T.R._._.]
[L.T.R._._.](TA)
Adjust:
[
.
.
.]
PTT:
ON
Press
[
] key to
store the adjust-
ment value.
1) Adj item: [LTR Devia-
tion (Analog Wide 5k)]
2) Adj item: [Hight],
[Hight](TA)
PTT:
Press
[Transmit]
button.
Press [Apply] button
to store the adjust-
ment value.
1.00kHz±0.05kHz