1-46 (No.RA018<Rev.002>)
4.9
Transmitter Section
5.
RTC
Corre-
citon
1) Adj item:
[RTC]
Adjust:[****]
Press [ ] key
to store the ad-
justment val-
ue.
1) Adj item:
[RTC Correction]
Data: {****]
Press [Apply] button
to store the adjust-
ment value.
Fre-
quency
Counter
Panel
TEST
POINT
(CN709
or
CN710)
[Panel
tuning
mode]
[
], [
]
[PC test
mode]
[
←
], [
→
]
[Panel tuning mode]
Press [ ] key to store
the adjustment value.
[PC test mode]
Press [Apply] button to
store the adjustment
value.
Remaks:
Change the adjust-
ment value so that
the frequency cur-
rently displayed on
“Crystal Oscillation
Frequency” on the
PC window and the
frequency currently
displayed on the
frequency counter
are in agreement.
Item
Condition
Measurement
Adjustment
Specifications
/Remarks
Panel tuning
mode
PC test mode
Test-
equip-
ment
Unit
Ter-
minal
Unit
Parts
Method
Item
Condition
Measurement
Adjustment
Specifica-
tions
/Remarks
Panel tuning
mode
PC test mode
Test-
equip-
ment
Unit
Ter-
minal
Unit
Parts
Method
1.
Ramp
up
Offset
1) Adj item:
[RAMPU]
Adjust:[****]
PTT : ON
Press [ ] key to
store the adjust-
ment value.
1) Adj item:
[Ramp Up Offset]
Press [Transmit]
button.
Press [Apply]
button to store the
adjustment value.
Power
meter
Ammeter
Panel ANT
Panel [Panel
tuning
mode]
[
],
[
]
[PC
test
mode]
[
←
],
[
→
]
[PC test mode]
[Automatic Adjust-
ment]
1) Press [Tune Rump
Offset] button.
2) Press [Apply All] but-
ton to store the adjust-
ment value after the
automatic adjustment
has finished.
[Manual Adjustment]
1) Set the adjustment
value to “1”.
2) Increase the adjust-
ment value slowly while
monitoring the offset
monitor value.
3) Set the adjustment
value when the offset
monitor value exceed
“50”.