MDX-F1
12
CIRCUIT DESCRIPTION
3. AUTO FAB adjusting mode
Step No.
Setting Method
Remarks
Display
Step 1
Test mode STOP state
Step 2
Press the MD REC button three times
AUTO FAB adjustment menu
[_AUT_FAB_ _]
Step 3
Press the MD PLAY button 1 time
End of automatic adj.
step 4
High reflection disc
step 5
Step 4
Press the MD STOP button
AUTO FAB adjustment menu, step 2
Step 5
Message output for 1 sec.
AUTO FAB.
Adjustment menu(high reflection disc)
¥
: measurement value
: FAB value in measurement,
: C1 error value in measurement,
: FAB
value
¥ If the STOP button is pressed while the AUTO FAB adjustment is displayed, the state is change to the TEST mode STOP
state.
¥ If the STOP button is pressed while the automatic adjustment is displayed, the state is change to the AUTO FAB
adjustment state.
Step 1
Test mode STOP state
[ t s m
e
]
Step 2
Press the MD REC button 4 times.
RESULT sub-menu
[ _ R S T _ Y O B I _ ]
Step 3
Press once the MD PLAY button. Indication of measurement value
[ R F G : _
_ _
_ _
]
Step 4
Press once the MD REC button.
Indication of measurement value
[ R C G : _
_ _
_ _
]
Step 5
Press once the MD REC button.
Indication of measurement value
[ R T G : _ _ _ _ _
]
Step 6
Press once the MD REC button.
Indication of measurement value
[ G T G : _ _ _ _ _
]
Step 7
Press once the MD REC button.
Indication of measurement value
[ P C H : _ _ _ _
]
Step 8
Press once the MD REC button.
Indication of measurement value
[ G C H : _ _ _ _
]
Step 9
Press once the MD REC button.
Indication of measurement value
[ S A G : _ _ _
]
Step 10
Press once the MD REC button.
Indication of measurement value
[ S B G : _ _ _
]
Step 11
Press once the MD REC button.
Indication of measurement value
[ S E G : _ _ _
]
Step 12
Press once the MD REC button.
Indication of measurement value
[ S F G : _ _ _
]
Step 13
Press once the MD REC button.
Indication of measurement value
[ H A O :
_ _ _]
Step 14
Press once the MD REC button.
Indication of measurement value
[ H B O :
_ _ _]
Step 15
Press once the MD REC button.
Indication of measurement value
[ H E O :
_ _ _]
Step 16
Press once the MD REC button.
Indication of measurement value
[ H F O :
_ _ _]
Step 17
Press once the MD REC button.
Indication of measurement value
[ L A O :
_ _ _]
Step 18
Press once the MD REC button.
Indication of measurement value
[ L B O :
_ _ _]
Step 19
Press once the MD REC button.
Indication of measurement value
[ L E O :
_ _ _]
Step 20
Press once the MD REC button.
Indication of measurement value
[ L F O :
_ _ _]
Step 21
Press once the MD REC button.
Indication of measurement value
[ T C O : _
_ _ _]
Step 22
Press once the MD REC button.
Indication of adjustment error sequence No.
[ Y O B : _
_ _ _]
Step 23
Press once the MD REC button.
Indication of adjustment status
[ D I F : _
_ _ _]
Step 24
Press once the MD REC button.
Indication of pre-adjustment not completed (00)/completed (4B)
[ A D J : _
_ _ _]
Step 25
Press once the MD STOP button. RESULT sub-menu state
[ _ R S T _ Y O B I _ ]
4. RESULT sub-mode
Step No.
Setting Method
Remarks
Display
: Measurement value,
: Adjustment value,
: Other various informations
When the FF(
¡
)button in remote controller is pressed while the setting is displayed, the setting increases,
and a new setting is stored in RAM.
When the FB(
1
)button in remote controller is pressed while the setting is displayed, the setting increases,
and a new setting is stored in RAM.
When the FF or FB button in remote controller is pressed continously, steps is change by 100ms period.