KDC-V6017,V6090R/RY,V7018R
6
Pin No.
Pin Name
I/O
Description
Processing Operation
Pin No.
Pin Name
I/O
Description
Processing Operation
MICROCOMPUTER'S TERMINAL DESCRIPTION
●
IC1 (ELECTRIC UNIT : X25-87XX-XX)
59
NC
O
Not used(N.C.)
60
NC
O
Not used(N.C.)
61
NC
O
Not used(N.C.)
62
NC
O
Not used(N.C.)
63
NC
O
Not used(N.C.)
64
NC
O
Not used(N.C.)
1
AM+B
O
AM+B control
"Hi": During AM reception.
2
FM+B
O
FM+B control
"Hi": During FM reception, "Hi": Last FM mode (only RDS model)
3
AFS
O
Noise detection time constant switching terminal
"Hi": During FM reception, "Lo": During FM seek or AF search
4
PLL-DATA
I/O Data input/output with F/E
5
PLL-CLK
I/O Clock input/output with F/E
6
EVDD
-
Power supply connection terminal
Connected to BU 5V lines.
7
EVSS
-
Ground connection terminal
Connected to GND.
8
NC
O
Not used(N.C.)
9
BEEP
O
BEEP sound output
10
REMO
I
Data input from the remote control light sensor
11
CH-REQH
O
Request output to changers
"Lo": Request
12
CH-RST
O
Reset output to changers
: Reset
13
IC2-SDA
I/O Data line with IC2, IC5 and CD MECHA. MI-COM.
14
IC2-CLK
I/O Clock line with IC2, IC5 and CD MECHA. MI-COM.
15
CH-MUTE
I
Mute request from changers
"Hi": Mute request
16
CH-CON
O
Changer control
"Hi": Operation mode, "Lo": Standby mode
17
DIMMER-CON/
O
Panel MI-COM. ON/OFF control
"Hi": POWER ON mode
SC-CON
"Lo": POWER OFF mode or panel detached or panel mask position
18
TEST
-
Test terminal
Not used(Connected to GND)
19
P-MUTE
O
Power IC mute control output
"Lo": Mute (POWER OFF, TEL MUTE)
20
P-STBY
O
Power IC standby control output
"Hi": POWER ON mode except panel detached or panel mask position
21
MUTE
O
IC2 mute control output
"Hi": Mute on
22
NC
O
Not used(N.C.)
23
PRE-MUTE
O
Pre-output Mute control output
"Lo": Mute
24
ACC-DET
I
ACC detection input
"Hi": ACC OFF, "Lo": ACC ON
25
DIMMER
I
Small lights detection input
"Lo": During vehicle small lamps turn on.
26
SW5V
O
SW 5V control output
"Lo": POWER ON mode or during CD loading/eject action
Bass boost OFF__"Hi": 160msec, "Lo": 40msec
27
EXT-AMP-CON
O
External amp. control output
Bass boost LOW__"Hi": 130msec, "Lo": 70msec
Bass boost HI__ "Hi": 100msec, "Lo": 100msec
28
P-CON
O
Power control output
"Hi": POWER ON mode except ALL OFF mode
29
ANT-CON
O
Antenna control output
"Hi": During FM/AM reception or TI reception
30
P-ON
O
SW 14V control output
"Hi": POWER ON mode or during CD loading/eject action
31
RESET
I
Reset input terminal
"Lo": System reset
32
XT1
I
Sub clock resonator connection terminal
Clock count during POWER OFF mode
33
XT2
-
Sub clock resonator connection terminal
34
REGC
-
C terminal
35
X2
-
Main clock resonator connection terminal
Oscillation stop: POWER OFF mode or momentary
power down detected
36
X1
I
Main clock resonator connection terminal
37
VSS
-
Ground connection terminal
Connected to GND lines.
38
VDD
-
Power supply connection terminal
Connected to BU 5V lines.
39
CLKOUT
O
Internal system clock output
40
NC
O
Not used(N.C.)
41
NC
O
Not used(N.C.)
42
TYPE0
I
Destination type input terminal 0
43
TYPE1
I
Destination type input terminal 1
44
TYPE2
I
Destination type input terminal 2