KDC-MP4032
11
●
MENU
• Press the [Q] key to enter the MENU.
• Press the remote control [DNPP/SBF] key or the [DIRECT]
key to enter the MENU.
• Continuous forwarding by remote control is prohibited.
●
Backup current measurement
If reset while in Acc OFF (Back Up ON) condition, MUTE
terminal goes off 2 seconds later, rather than 15 seconds.
(During this time, the CD mechanism does not function.)
●
Initializing AUDIO-related setting value
Press the [
] key in the STANDBY source and reset the
AUDIO setting value to the test mode default value.
●
Other
• When Power ON, do not display “CODE_OFF” and
“CODE_ON”.
• When started in Test Mode, duration of prohibiting LINE
MUTE shall be changed from 10 seconds to 1 second.
• When in test mode, do not write security code by security
jig.
• While in Test Mode, serial number is not written with a se-
rial-number-writing jig.
• When in Test Mode, when DC offset error detection is run,
the detection information is not written into the E2PROM.
• DEMO mode shall not be operated while in Test Mode, CD
Mechanism Error Log Data Clearing Mode, or DC Offset
Error Detection Data Clearing Mode.
Also, do not display DEMO ON/OFF option items in the
MENU in STANDBY source in the above modes.
●
Special displays while all lights are on
When all lights are on with STANDBY source, if the follow-
ing keys are pressed, the following messages are displayed.
[1] key
Version is displayed (forwarding)
(Display) TYPE : x_ _ _ (“x” is displayed in hexadecimals)
→
518K – 1.02 (“development ID” – “version”)
→
all lights on
→
∗
TYPE indicates
µ
-com destination, and shows real-time
condition of the destination terminal.
[2] key
Serial No. is displayed (8 digits)
(Display) xxxxxxxx
[3] key
Key pressed: Power ON time is displayed.
While Power ON time is displayed, press and hold for 2
seconds or longer to clear the Power ON time.
(Display)
PON_0Hxx (00~50 is displayed for “xx”. When less
than 1 hour, display by increment of 10
minutes.)
xxxxx (00001~10922 is displayed for “xxxxx”)
MAX 10922 (hours)
[4] key
Key pressed: CD operation time is displayed.
Press the key for more than 2 seconds while the CD
operation time is displayed to clear CD operation time.
(Display)
CDT_0Hxx (00~50 is displayed for “xx”. When less
than 1 hour, display by increment of 10
minutes.)
xxxxx (00001~10922 is displayed for “xxxxx”)
MAX 10922 (hours)
[5] key
Key pressed: Number of CD EJECT time is displayed.
While the CD EJECT times is displayed, press and hold
for 2 seconds or longer to clear the number of CD EJECT
times.
(Display) EJCxxxxx
MAX 65535 (times)
[6] key
Key pressed: Number of times PANEL is opened/closed
is displayed.
Press the key for more than 2 seconds while the PANEL
open/close count is displayed to clear the PANEL open/
close count.
(Display) PC_xxxxx
MAX 65535 (times)
TEST MODE