16
KDC-4047UA/4047UG/4047UGY/4047UM
KDC-414UA/414UM/MP245U/U3046/U346/U4046
TEST MODE
• RDS automatic measurement
This automatic measurement is implemented in place of the visual inspection of the PS display that had been carried out in the production line.
Status
Description of display
Description
PS data reception
R
D
S
T
E
S
T
The P-CON is forcibly turned off when the display in the left cell is shown.
P-CON is recovered by turning the power OFF and ON (Power OFF/ON).
■
Test mode in CD source
Display mode default
P-Time
• Procedure in CD-DA media (KTD-02A)
Key
Description of display
Operation
Track up procedure
Every time pressed, jumps to the track shown below.
No.9
→
No.15
→
No.10
→
No.22
→
No.12
→
No.13
→
No.14
→
No.9 (recursive)
But in case the disc has 8 tracks or less, playback starts with
track No.1 (at both of CD-DA and compressed
fi
le disc).
Track down procedure
Goes down by 1 track from the currently played track.
1
Jump procedure
Jump to No.28. (0.7mm scratch for MUSIC line vibration test)
2
Jump procedure
Jump to No.14. (Blurring surface disc: TCD-731RA Tr14)
3
(forward
rotation)
Information display
Mechanism model name
Mechanism version
9
B
2
0
Mechanism model name and mechanism version display
Information display
Mechanism Servo version
S
E
R
V
Mechanism servo table version display
Information display
Mechanism Boot program
version
B
O
O
T
Mechanism boot program version display
4
Jump procedure
Jump to No.15. Set the volume value to “26”.
(For 20Hz 0dB DC protection error operation FCT checking)
5
Jump procedure
∗
Switch the track jump from No.9 to
No.22 or from No.22 to No.9 (No.9
↔
No.22)
When the track No.22 is being played back, this key makes
the track jump to No.9.
When the track No.9 is being played back, this key makes
the track jump to No.22.
6
PLAY/PAUSE procedure
This key is to switch from PLAY to PAUSE and vice versa
(PLAY/PAUSE). (Normal operation)