4
KDC-237SA/237SAY
KDC-237SG/237SGY
Ref. No.
Application / Function
Operation / Condition / Compatibility
Q2
Q1 SW
Q2 is ON when Q6 is ON.
Q3
5V-3.3V Level Shift
Shifts 5V to 3.3V, or 3.3V to 5V.
Q4
5V-3.3V Level Shift
Shifts 3.3V to 5V.
Q6
BU3.3V SW
Q6 is ON when Q8 or Q9 is ON.
Q7
APC (Auto Power Control)
Drives LD (Laser Diode).
Q8
Power Supply Control
Power Supply Control from MECHA
µ
-COM. Q6 is ON when pin 63 (P_ON1) of IC1 is Hi.
Q9
Power Supply Control
Power Supply Control from system
µ
-COM. Q6 is ON when pin 125 (MSTOP) of IC1 is Hi.
D1,2
5V Force Voltage Prevention
5V Force Voltage Prevention from MECHA
µ
-COM side.
D3
Laser Diode Protection
Prevents reverse bias which is applied to laser. Laser destruction prevention.
D4
Static Electricity Countermeasure
Prevents malfunction by static electricity.
●
SYSTEM
µ
-COM: IC1 on X34- (ELECTRIC UNIT)
Pin No.
Pin Name
I/O
Application
Truth Value
Processing Operation Description
Table
1
LX DATA M
I/O
Data to slave unit
Pull-down (GND)
2
LX CLK
I/O
LX-BUS clock
125k~65kHz
3~5
NC
-
Not used
Output Lo fixed
6
REMO
I
Remote control signal input
Detects pulse width
7
NC
-
Not used
Output L fixed
8
BYTE
I
Memory extended bus width setting
Connects to VSS
9
CNVSS
-
Connects to VSS
10
XCIN
-
32.768kHz
11
XCOUT
-
32.768kHz
12
RESET
-
L: Reset
13
XOUT
-
10.0MHz
14
VSS
-
15
XIN
-
10.0MHz
16
VCC1
-
17
NMI
I
Connects to VSS
18
PANEL DET
I
Panel communication detection
H: Panel detached, L: Panel attached
19,20
NC
-
Not used
Output L fixed
21
ROMCOR DET
I
E2PROM writing request
H: Writing
22,23
NC
-
Not used
Output L fixed
MICROCOMPUTER’S TERMINAL DESCRIPTION
COMPONENTS DESCRIPTION