8
KDC-208U/248U/4051UGM/4051URM/MP148U/MP248U
KDC-U3049/U349A/U349G/U349R/U349S/U4049
Operation
Display content
Details
■
DISP
CD error information
clear
CD error information all clear
DISP
Mode release
CD error information display mode release
6. DC Error Information Mode
●
Default status immediately after the mode activation
It shall be same as normal activation.
●
Mode structure
DC Error Info Mode is enabled regardless of current source.
●
Mode content
Syscon shall display the following information after entering this mode. The operation shown below shall be workable.
Display content
Details
D
C
E
R
R
When DC error is detected (in case that one of capacitor leakage, wrong connection or other
detection is found)
D
C
O
K
When DC error is not detected (in case that none of capacitor leakage, wrong connection or
other detection is not found)
●
Mode operation speci
fi
cation
Operation
Display content
Details
1
DC ERR1display
D
C
1
E
R
R
When wrong connection & DC error in other detection dura-
tion is detected
D
C
1
O
K
When wrong connection & DC error in other detection dura-
tion is not detected
■
1
DC ERR1 clear
D
C
1
O
K
Clear detection information when wrong connection & DC er-
ror in other detection duration is displayed. (Clear data
fl
ash)
2
DC ERR2 display
D
C
2
4
Display detecting number of times in capacitor leakage de-
tection duration (0~4)
■
2
DC ERR2 clear
D
C
2
0
Clear number of times for detection information in capacitor
leakage detection duration. (Clear data
fl
ash)
7. FM/AM channel space switching
Procedure
Note
While Power OFF, pressing and holding [1] key and [5] key, and press [SRC]
key to Power ON.
FM200kHz/AM10kHz
↔
FM50kHz/AM9kHz
TEST MODE