background image

English

  5

Controls

1

 Fuse (30 A × 2)

2

 Battery terminal

3

 Ground terminal

4

 Power control terminal

Controls the unit ON/OFF.

NOTE

Controls the unit power. Be sure to connect it with all the systems.

5

 Speaker output terminals

• Stereo Connections:

When you wish to use the unit as a stereo amplifier, stereo connections are 
used.
The speakers to be connected should have an impedance of 2Ω or greater. 
When multiple speakers are to be connected, ensure that the combined 
impedance is 2Ω or greater for each channel.

• Bridged Connections:

When you wish to use the unit as a high-output monaural amplifier, 
bridged connections are used. (Make connections to the LEFT channel 

9

 

and the RIGHT channel 

·

 SPEAKER OUTPUT terminals.)

The speakers to be connected should have an impedance of 4Ω or greater. 
When multiple speakers are to be connected, ensure that the combined 
impedance is 4Ω or greater.

2

 CAUTION

The rated input of the speakers should be no less than the maximum output 
of the amplifier. Otherwise malfunction may result.

6

 RCA cable ground lead terminal

When using an RCA cable with a ground lead attached, connect the ground 
lead to this terminal.

7

 ID NUMBER switch

Sets an amp identification number (ID) to be used for amplifier control from 
the Center Unit.
Assign ID Number "0" to an amplifier when you use it as the Master amplifier.
Assign ID Numbers "1" to "7" to amplifiers when you use them as Slave 
amplifiers. Do not duplicate these numbers.

NOTE

After you have changed ID numbers of amplifiers, turn Off the POWER switch 
of the Center Unit and turn it On again.

8

 TO H/U terminal

After you have set the Master amplifier, connect it to the Center Unit.

9

 REMOTE terminals

Used to connect to Slave amplifiers.

0

 RESET button

Resets the microprocessor of the unit.

NOTE

The values you have set with the Amplifier Control are NOT reset.

!

 LINE IN terminal

@

 LINE OUT terminal

The signal that’s input from the line input terminal is output. 

#

 Power indicator 

Lights when the POWER switch is turned On.
The indicator flashes several seconds when the POWER switch is turned On 
or when the Protection function is activated.

$

 LPF FREQUENCY control 

Sets the cutoff frequency when the "FILTER" switch is set to "LPF".

%

 HPF FREQUENCY control 

Sets the cutoff frequency when the "FILTER" switch is set to "HPF".

^

 FILTER switch

This switch allows to apply high-pass or low-pass filtering to the speaker 
outputs.

•  HPF (High-Pass Filter) position:

The filter outputs the band of higher frequencies than the frequency set 
with the "HPF FREQUENCY" control.

• OFF position:

The entire bandwidth is output without filtering.

•  LPF (Low-Pass Filter) position:

The filter outputs the band of lower frequencies than the frequency set 
with the "LPF FREQUENCY" control.
The speaker output is automatically switched to monaural (L+R).

&

 AMP CONT (amplifier control) switch

Used to bypass the circuit when you do not control the sound with the 
Amplifier Control.

• ON position:

Allows you to control the sound with the Amplifier Control.

• OFF position:

Bypasses the Amplifier Control circuit.

NOTE

Amplifier control is possible even while OFF.

*

 ISF (infrasonic filter) switch

When this switch is "ON", the frequencies which are below the audible 
range and therefore inaudible are cut off so that the quality of the audible 
frequencies can be improved.

(

 OPERATION switch

This switch is used to select the operation mode of the amplifier.

• STEREO position:

The amplifier can be used as a stereo amplifier.

• MONO (Lch) position:

Amplifies the signal input from the left side only. Set to this position and 
make bridged connections to use as a high-power monaural amplifier. (The 
input right signal is not output.)

)

 INPUT SENSITIVITY control 

Set this control according to the pre-output level of the center unit 
connected with this unit.

NOTE

For the pre-output level, refer to the <Specifications> in the instruction 
manual of the center unit.

30

30

01

2

3

4

5 6

7

8

%

#

& * (

)

^

$

7

6

8 9

0

4

5

3

2

1

@

!

B64-3394-00̲00.indb   5

B64-3394-00̲00.indb   5

05.11.18   9:12:12 AM

05.11.18   9:12:12 AM

Summary of Contents for KAC-X522

Page 1: ...dures will help you obtain the best performance from your new power amplifier For your records Record the serial number found on the back of the unit in the spaces designated on the warranty card and in the space provided below Refer to the model and serial numbers whenever you call upon your Kenwood dealer for information or service on the product Model KAC X522 Serial number US Residence Only Re...

Page 2: ...e When the unit is used in the ACC ON position without turning the engine ON it depletes the battery Use it after starting the engine Protection function There is a Protection function installed in the unit to protect the unit and speakers from various problems When Protection operates the display informs you of the condition Display Informations E 01 When the inside of the unit is overheating E 0...

Page 3: ... In a place that gets hot In a place that gets direct sunlight In a location that gets hit by hot air Do not install the unit under the carpet Otherwise heat build up occurs and the unit may be damaged Install this unit in a location which allows heat to easily dissipate Once installed do not place any object on top of the unit The surface temperature of the amplifier will become hot during use In...

Page 4: ...unconnected wires or connectors to prevent short circuits Connect the speaker wires to appropriate speaker connectors separately Sharing the negative wire of the speaker or grounding speaker wires to the metal body of the car can cause this unit to fail After installation check that the brake lamps winkers and wipers work properly RCA cable Slave amplifier 7 Extension wire Set the ID number of the...

Page 5: ... from the line input terminal is output Power indicator Lights when the POWER switch is turned On The indicator flashes several seconds when the POWER switch is turned On or when the Protection function is activated LPF FREQUENCY control Sets the cutoff frequency when the FILTER switch is set to LPF HPF FREQUENCY control Sets the cutoff frequency when the FILTER switch is set to HPF FILTER switch ...

Page 6: ...kHz Treble Center Frequency TR G T 15 T 15 dB Treble level VOL 20 0 dB Volume offset TEMP FAHR Fahrenheit or CELS Centigrade The Fahrenheit or Centigrade temperature unit can be selected for the Display mode DEFA For the operation method refer to Default AMP 0 7 The ID Number you have assigned is displayed 4 Exit Menu mode Press the MENU button for at least 1 second NOTE When you hold down the 3 b...

Page 7: ...er Frequency BAS G BASS GAIN 15 15 dB Bass level Q FA Q FACTOR Q1 00 Q1 25 Q1 50 Q2 00 Bass Q Factor EXT BASS EXT ON OFF When the bass extend is set to ON low frequency response is extended by 20 TRE F TREB FREQ 10 12 15 17 kHz Treble Center Frequency TRE G TREB GAIN 15 15 dB Treble level VOL VOL OFFSET 20 0 dB Volume offset AMP NO AMP CONTROL NO 0 7 Select an ID number of the amp you use 6 Exit A...

Page 8: ...C 0 dB 3 dB Coil L Passes low frequencies and blocks high frequencies Low pass Capacitor C Passes high frequencies and blocks low frequencies High pass Crossover Frequency Frequency 159000 C μF fc R 159 x R L mH fc fc Cut of Frequency Hz R Speaker Impedance Ω Example When it is required to set a crossover frequency of 120 Hz using speakers with an impedance of 4 ohms Prepare commercially available...

Page 9: ... be operated from the Center Unit An incorrect ID number is used for the Master amplifier The ID number of the amplifier has been changed Always set the ID number of the Master amplifier to 0 After you have changed the ID number of an amplifier turn Off the POWER switch of the Center Unit first then turn it On again Specifications Specifications subject to change without notice Audio Section Max P...

Page 10: ... de protection Une fonction de protection est installée dans l unité afin de protéger l unité et les enceintes de divers problèmes Lorsque la protection fonctionne l affichage vous informe de l état Affichage Information E 01 Lorsque l intérieur de l unité est en surchauffe E 02 Lorsque l unité est en panne et que l intensité du courant continu est transmise à la sortie haut parleur REMARQUE Etein...

Page 11: ...as recouvrir l appareil d une nappe tapis etc la chaleur qui s accumulerait risque d endommager l appareil Installer cet appareil à un emplacement tel que la chaleur puisse se dissiper aisément Après l installation ne placer aucum objet sur l appareil La surface de l amplificateur va chauffer pendant l utilisation Installer l amplificateur à un endroit où des passagers de la résine ou d autres sub...

Page 12: ... tout courtcircuit Raccorder séparément les câbles de haut parleur aux connecteurs de haut parleur appropriés La mise en commun du câble négatif d un haut parleur ou des fils de masse des haut parleurs à la carrosserie métallique de la voiture pourrait rendre l appareil inopérant Après l installation vérifier que les voyants de frein les clignotants et les essuie glace fonctionnent correctement Câ...

Page 13: ...t d alimentation S allume lorsque le commutateur POWER est mis en marche Le voyant clignote pendant plusieurs secondes lorsque le commutateur POWER est mis en marche ou lorsque la fonction de protection est activée Commande LPF FREQUENCY Cette commande permet de préciser la fréquence de coupure quand le commutateur FILTER est sur la position LPF Commande HPF FREQUENCY Cette commande permet de préc...

Page 14: ... 0 dB Décalage de volume TEMP FAHR Fahrenheit ou CELS Centigrade L unité de température Fahrenheit ou Centigrade peut être sélectionnée pour le mode d affichage DEFA Pour la méthode de fonctionnement référez vous à Par défaut AMP 0 7 Le numéro d identification que vous avez attribué s affiche 4 Sortez du mode menu Appuyez sur la touche MENU pendant au moins 1 seconde REMARQUE Lorsque vous maintene...

Page 15: ...80 100 200 Hz Fréquence centrale de basse BAS G BASS GAIN 15 15 dB Niveau de basses Q FA Q FACTOR Q1 00 Q1 25 Q1 50 Q2 00 Facteur d amplification dynamique Q EXT BASS EXT ON OFF Lorsque l expansion de basses est activée la réponse en basse fréquence est augmentée de 20 TRE F TREB FREQ 10 12 15 17 kHz Fréquence centrale d aigus TRE G TREB GAIN 15 15 dB Niveau d aigus VOL VOL OFFSET 20 0 dB Décalage...

Page 16: ...aisse passer les fréquences aiguës mais bloque les fréquences graves filtre passe haut Fréquence de recoupement Fréquence 159000 C μF fc R 159 x R L mH fc fc Fréquence de recoupement Hz R Impédance du haut parleur Ω Exemple Cas où il faut établir la fréquence de transition à 120 Hz en utilisant des haut parleurs ayant une impédance de 4 ohms Se procurer dans le commerce la bobine et le condensateu...

Page 17: ...ilisée Débloquez le mode de commande AMP de l unité centrale La commande d amplificateur ne peut être commandée à partir de l unité centrale Un numéro d identification incorrect est utilisé pour l amplificateur maître Le numéro de l amplificateur a été changé Réglez toujours le numéro d identification de l amplificateur maître sur 0 Après avoir modifié le numéro d identification d un amplificateur...

Page 18: ... el fin de proteger a la unidad y a los altavoces de algunos problemas Cuando dicha protección funciona la pantalla informa sobre esta condición Visualización Información E 01 Cuando el interior de la unidad se recalienta E 02 Cuando la unidad ha fallado y se genera tensión de corriente directa hacia la salida del altavoz NOTA DESCONECTE la alimentación y liere la protección Si el código E 02 no d...

Page 19: ...n lugar en el que reciba la luz directa del sol En un lugar situado en el flujo de aire caliente No utilice el aparato bajo una alfombra porque en caso contrario éste podría sobrecalentarse y estropearse Instale este aparato en un lugar donde el calor pueda disiparse fácilmente Una vez instalado no ponga nada sobre él La temperatura de la superficie del amplificador se elevará durante su uso Insta...

Page 20: ...e los cables o conectores que están sin conectar para evitar de que se produzcan cortocircuitos Conecte los cables del altavoz a los conectores adecuados del altavoz separadamente La puesta en contacto de terminales de altavoces distintos o la conexión como toma de tierra de los terminales del altavoz al coche del automóvil pueden causar daños a la unidad Después de la instalación compruebe que la...

Page 21: ...minal de entrada de línea es la salida Indicador de alimentación Se ilumina cuando se activa el interruptor POWER El indicador parpadea durante varios segundos cuando se activa el interruptor POWER o cuando se activa la función de protección Control LPF FREQUENCY Ajusta la frecuencia de corte cuando el conmutador FILTER está en LPF Control HPF FREQUENCY Ajusta la frecuencia de corte cuando el conm...

Page 22: ...2 15 17 kHz Frecuencia central de agudos TR G T 15 T 15 dB Nivel de agudos VOL 20 0 dB Compensación de volumen TEMP FAHR fahrenheit o CELS centígrados Es posible seleccionar para el modo de visualización la temperatura en grados fahrenheit o centígrados DEFA Para el método de funcionamiento remítase a Ajustes de fábrica AMP 0 7 El número ID que ha asignado se visualiza 4 Salir del modo de menú Pul...

Page 23: ... BASS FREQ 60 80 100 200 Hz Frecuencia central de graves BAS G BASS GAIN 15 15 dB Nivel de graves Q FA Q FACTOR Q1 00 Q1 25 Q1 50 Q2 00 actor Q de graves EXT BASS EXT ON OFF Cuando la extensión de graves se activa la respuesta de baja frecuencia se extiende en un 20 TRE F TREB FREQ 10 12 15 17 kHz Frecuencia central de agudos TRE G TREB GAIN 15 15 dB Nivel de agudos VOL VOL OFFSET 20 0 dB Compensa...

Page 24: ... y bloquea las bajas frecuencias Paso alto Frecuencia de cruce Frecuencia 159000 C μF fc R 159 x R L mH fc fc Frecuencia de cruce Hz R Impedancia de altavoces Ω Ejemplo Cuando sea necesario ajustar una frecuencia de cruce de 120 Hz utilizando altavoces con una impedancia de 4 ohmios Prepare una bobina y un capacitor de venta en el comercio del ramo que tengan unas especificaciones nominales lo más...

Page 25: ...e utiliza un número de ID incorrecto para el amplificador principal El número de ID del amplificador se ha modificado Ajuste siempre el número de ID del amplificador principal a 0 Después de que haya modificado el número de ID de un amplificador desactive primero el interruptor POWER de la unidad central y luego actívelo nuevamente Especificaciones Especificaciones sujetas a cambios sin previo avi...

Page 26: ...B64 3394 00 00 indb 26 B64 3394 00 00 indb 26 05 11 18 9 12 28 AM 05 11 18 9 12 28 AM ...

Page 27: ...B64 3394 00 00 indb 27 B64 3394 00 00 indb 27 05 11 18 9 12 28 AM 05 11 18 9 12 28 AM ...

Page 28: ...B64 3394 00 00 indb 28 B64 3394 00 00 indb 28 05 11 18 9 12 28 AM 05 11 18 9 12 28 AM ...

Reviews: