background image

For the pre-output level or the maximum power output, refer to the “Specifications” in the
instruction manual of the center unit.

0

RCA cable ground lead terminal

!

LINE IN terminal

@

Speaker level input terminals

NOTE

Power indicator:

When the power is turned on, the Power indicator lights.
If the Power indicator does not light when the power is turned on, the
protection function may be activated. Check whether there is any
indication of trouble.

The protection function is activated in the following
situations:

This unit is equipped with a protection function for protecting this unit
and your speakers from various accidents or problems that can occur.
When the protection function is triggered, the Power indicator goes off
and the amplifier stops operating.
• A speaker cable may be short-circuited.
• A speaker output may be in contact with the ground.
• The temperature of the internal parts may be higher than 120°C (248°F).
• The sigma servo connection may be erroneous.
• The fuse of this unit may be blown.
• The unit may be malfunctioning and sending DC signal to the speaker output.
• The grounding cable of this unit may not be connected with a metallic part which is

electrically connected with the negative terminal of the battery.

• The power control cable may not be connected to this unit.
• The grounding cable of the center unit (cassette receiver, CD receiver, etc.) may not be

connected with a metallic part which is electrically connected with the negative terminal of
the battery.

English

5

Power indicator

Power indicator

Summary of Contents for KAC-818

Page 1: ...KAC 818 B64 1355 00 EM MONO POWER AMPLIFIER INSTRUCTION MANUAL ...

Page 2: ... exposed to direct sunlight or excessive heat or humidity Also avoid places with too much dust or the possibility of water splashing When replacing a fuse only use a new one with the prescribed rating Using a fuse with the wrong rating may cause your unit to malfunction To prevent a short circuit when replacing a fuse first disconnect the wiring harness If you experience problems during installati...

Page 3: ...t such as the brake lamps turn signal lamps and windshield wipers operate normally 2CAUTION Installation board etc thickness 15 mm or more Self tapping screw ø4 16 mm 1 Remove the ignition key and disconnect the negative terminal of the battery to prevent short circuits 2 Set the unit according to the intended usage 3 Connect the input and output cables of the units 4 Connect the center unit and t...

Page 4: ... 6 SIGMA SERVO FEED BACK terminals See p 8 Be sure to make proper connections to the SIGMA SERVO FEED BACK terminals Incorrect connection may result in lack of sound output or other malfunctions 7 INFRASONIC FILTER switch Ultralow frequencies that cannot be reproduced even by a subwoofer speaker do not become sound but become unnecessary oscillations which affect the sound by causing distortion et...

Page 5: ... the protection function is triggered the Power indicator goes off and the amplifier stops operating A speaker cable may be short circuited A speaker output may be in contact with the ground The temperature of the internal parts may be higher than 120 C 248 F The sigma servo connection may be erroneous The fuse of this unit may be blown The unit may be malfunctioning and sending DC signal to the s...

Page 6: ...NPUT LEFT RIGHT SPEAKER LEVEL INPUT MONO POWER AMPLIFIER L 25Hz 15Hz INFRASONIC OFF INPUT SENSITIVITY V LPF FREQUENCY Hz GND R LINE IN 0 3 0 5 1 2 3 4 5 0 2 150 100 70 50 200 LEFT RIGHT SPEAKER LEVEL INPUT RCA cable connection CENTER UNIT Cassette receiver CD receiver etc Power control cable Commercially available part RCA cable Commercially available part Do not connect cables and leads to both R...

Page 7: ... protective fuse into the battery wire close to the battery Use a protective fuse having a capacity that is about 10 A higher than the maximum current drawn by the amplifier Use vehicle type fire resistant power supply wiring wire for the battery wire and the ground wire The current capacity of the power supply wiring wire should be about 10 A higher than that of the protective fuse capacity which...

Page 8: ... servo terminals etc If the Sigma servo terminals are not connected the sound may fluctuate or noise may occur Be sure to connect the Sigma servo terminals correctly When connecting speakers in a parallel configuration use speakers with an impedance of 4 ohms or more Connecting speakers with smaller impedance than 4 ohms will cause malfunction The rated input of the speakers connected to this unit...

Page 9: ... calling service first check the following table for possible problems PROBLEM POSSIBLE CAUSE SOLUTION No sound No sound from one side The output level is too small or too large The sound quality is bad The sound is distorted Input or output cables are disconnected The connection of the sigma servo terminals is wrong Protection circuit may be activated The fuse may be blown because the volume was ...