14
DPX301
DPX-MP2090/MP2090S
TEST MODE
CD loading error log display (switched by [
] / [
] keys)
(Display) LDERR1: xx
↔
LDERR2: xx
↔
LDERR1: xx
↔
(Number of times is displayed for “xx”)
MAX 99 (times)
Disk detection switch ON/OFF is monitored, and when the
loading operation is not completed within the specified
time length, or when E-99 mechanism error occurred,
record which SW signal had an error.
∗
Refer to [CD LOAD error detection]’s note.
CD ejection error log display (switched by [
] / [
] keys)
(Display) EJERR1: xx
↔
EJERR2: xx
↔
EJERR3: xx
↔
EJERR4: xx
↔
EJERR1: xx
↔
(Number of times is displayed for “xx”)
MAX 99 (times)
Disk detection switch ON/OFF is monitored, and when the
loading operation is not completed within the specified
time length, or when E-99 mechanism error occurred,
record which SW signal had an error.
∗
Refer to [CD LOAD error detection]’s note.
CD time code error count data display (missing counts)
(switched by [
] / [
] keys)
(Display) CNT_LOSE
↔
CDDA_ _: xx
↔
CDROM_: xx
↔
CNT_LOSE
↔
(Number of times is displayed for “xx”)
MAX 99 (times)
Monitor time code continuity. Record the number of times
when discontinuity occurred as error data.
Record the data of compressed audio and CD-DA played
separately.
CD time code error count data display (count not updated)
(switched by [
] / [
] keys)
(Display) CNT_STAY
↔
CDDA_ _: xx
↔
CDROM_: xx
↔
↓
CNT_STAY
↔
[FM]
(Number of times is displayed for “xx”)
key
MAX 99 (times)
When the time code is not renewed for 2 or more
seconds, record the number of times occurred as error
data. (skipped sound)
●
Initializing AUDIO-related setting value
Press the [
] key in the STANDBY source and reset the
AUDIO setting value to the test mode default value.
●
Other
• When Power ON, do not display “CODE_OFF” and
“CODE_ON”.
• When the source is STANDBY, press and hold [AUTO] key
for 1 second to switch PREOUT Rear and Sub Woofer.
(2PREOUT model)
• When started in Test Mode, duration of prohibiting LINE
MUTE shall be changed from 10 seconds to 1 second.
• While in Test Mode, serial number is not written with a se-
rial-number-writing jig.
• When in Test Mode, when DC offset error detection is run,
the detection information is not written into the E2PROM.
• DEMO mode shall not be operated while in Test Mode, CD
Mechanism Error Log Data Clearing Mode, or DC Offset
Error Detection Data Clearing Mode.
Also, do not display DEMO ON/OFF option items in the
MENU in STANDBY source in the above modes.
●
Clearing CD mechanism information and
service information (Clearing E2PROM (F/E) data)
1. While pressing the [Q] key and [ATT] key, reset-start to start
CD mechanism and service information initialization.
(While “– – – –“ is being displayed, power can be ON for 30
minutes.)
[CD mechanism information]
• Displays I2C communication condition
• Displays CD mechanism error log
• Displays CD loading error data.
• Displays CD ejection error data
• Displays CD time code error count data (missing count)
• Displays CD time code error count data (count not updated)
[Service information]
• Displays power ON time is displayed
• Displays CD operation time
• Displays number of CD EJECT times
• Displays forced Power OFF data
2. After the initialization process is completed, the following is
displayed.
When successfully completed: “CD_O_ _ _ _”
When finished but unsuccessful: “CD_X_ _ _ _”
3. This mode is cancelled by resetting. (The last screen will