![Kenwood CK 405 Instructions For Use - Installation Advice Download Page 37](http://html.mh-extra.com/html/kenwood/ck-405/ck-405_instructions-for-use-installation-advice_189995037.webp)
37
LUBRICATION OF THE GAS TAPS
•
In case of difficulty in the gas taps operation, call Service.
IMPORTANT
All intervention regarding installation maintenance of the appliance must be fulfilled
with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this
obligation.
BURNERS
Nominal
power
[kW]
Reduced
power
[kW]
LPG
G30 28-30 mbar
G31 37 mbar
Natural Gas
G20 20 mbar
Ø
injector
[1/100 mm]
Air ring
opening
[mm]
Ø
injector
[1/100 mm]
Air ring
opening
[mm]
Auxiliary (A)
1,00
0,30
50
-
77
-
Semi-rapid (SR)
1,75
0,45
66
-
101
-
Rapid (R)
3,00
0,75
87
-
129
-
Triple-ring (TR)
3,50
1,50
93
-
135
-
Left Oven
3,70
0,75
92
Fully open (*)
140
5 (*)
Left Grill
2,50
-
80
Fully open (*)
120
4 (*)
Right Oven
2,20
0,63
72
Fully open (*)
110
4 (*)
(*) = Reference value
AIR VENT NECESSARY FOR GAS COMBUSTION = (2 m
3
/h x kW)
BURNERS
Air necessary for combustion [m
3
/h]
Auxiliary (A)
2,00
Semi-rapid (SR)
3,50
Rapid (R)
6,00
Triple-ring (TR)
7,00
Left Oven
7,40
Left Grill
5,00
Right Oven
4,40
TABLE FOR THE CHOICE OF THE INJECTORS
GB
Cat:
II
2H3+
Summary of Contents for CK 405