IMPORTANT: The cooker must be installed in accordance with the
manufacturer’s instructions.
Incorrect installation, for which the manufacturer accepts no responsbility,
may cause injury to persons or animals etc.
Before effecting any intervention on the electrical parts of the appliance,
the connection to the network must be interrupted.
The connection of the appliance to earth is mandatory.
The manufacturer declines all responsability for any inconvenience
resulting from the inobservance of this condition.
10 - ELECTRICAL INSTALLATION
The appliance must be connected to the electrical network verifying above all that the
voltage corresponds to the value indicated on the specifications plate and that the cables
section of the electrical plant can bear the load which is also indicated on the plate.
It is recommended that the appliance is connected directly to the mains by fixed wiring,
placing a double pole switch with minimum opening between the contacts of 3 mm.
Alternative connection methods may be available as long as they conform to current IEE
wiring regulation.
The power supply cable must not touch the hot parts and must be positioned so that it does
not exceed 75°C at any point.
Once the cooker has been installed, the switch must always be accessible.
Before effecting any intervention on the electrical parts the appliance must be disconnected
from the network.
CONNECTION TO FIXED WIRING
A double pole switch must be provided no further than 2 metres from the appliance to the
electrical supply.
We recommend that the appliance is connected by a suitably qualified person who will
comply with the IEE and local regulation.