Details of the MidiStream SysEx messages

 

 
SysEx messages exclusive to the 

MidiStream

 system are made up as follows: 

 
[1]   

F0

  - Begin SysEx command 

[2]   

00

  - Company ident first byte 

[3]   

20

  - Company ident second byte 

[4]   

13

  - Company ident third byte 

[5]   

0B

  - Product code – 

MidiStream

 System 

[6]   

aa

  - Address byte – where address 00 is for setting timeout (no other addresses valid at this time) 

[7]   

dd

  - Data byte – where data values of 00 – 7Fh (0 – 127 decimal) are valid values 

[8]   

F7

  - End of SysEx 