4
Troubleshooting
Check that you are using a properly wired CAT5 cable
– see above.
Check that you are using a “straight through” cable,
not
a “crossover” cable.
Check that the “active” LEDs are lit.
If you encounter problems at very long distances, it could be the result of volt-drop in
the CAT5 cable, in which case substituting the power supply for a 12 or 15 volt unit
type will help. Note that we have tested the LNDR system to over 750 metres using
the supplied PSU without problems.
Specification
Power Input
9V to 12V DC (regulated or unregulated)
Power
85mA, 2.1mm plug (centre positive)
MIDI
1 x In, 1 x Out on each unit (standard 5 pin DIN connectors)
Interconnect
CAT5 cable required with RJ45 connectors
Protocols
MIDI and RS485 full duplex
Range
500 metres between master & slave over CAT5e cable
Weight
110g (each unit, excluding power supply)
Dimensions
100 x 46 x 32 mm (each unit)
Power supply
Supplied with unit. Specify UK EU or US type when ordering.
Warranty
The
LNDR
system comes with a 12 month (from purchase date) back to base
warranty, (i.e. customer must arrange and pay for carriage to and from Kenton
Electronics Ltd). In the unlikely event of a problem, contact us by email through our
website or by telephone.
www.kenton.co.uk
Kenton Electronics Limited
Brookfarm House, Station Road, South Wimbledon, London, SW19 2LP, UK
Tel: +44 (0)20 8544 9200 Fax: +44 (0)20 8544 9300
Version # 1v00 e. & o. e.
©
8
th
March 2017