4
FACTORY DEFAULTS
If you want to reset your
GPIM-16
to its factory default settings, you can do so by applying power to the
unit whilst holding the recessed edit button pressed.
`
def
` (factory defaults) will momentarily be displayed when this has been done.
The factory default settings are:
MIDI channel #1
GPI 1-8 midi notes 36-43,
GPI 1-8 MIDI off enabled (yes)
GPI 9-16 midi notes 44-51
GPI 1-8 MIDI off enabled (yes)
Debounce time 5mS
Output message type=notes
DISPLAYING THE FIRMWARE VERSION NUMBER
Power the unit on while holding the ‘dec’ button pressed – keep pressed while you read the number.
When you release the button you will be in analyser mode. Pressing all three buttons
mode
,
dec
and
inc
together will exit analyser mode and return the unit to normal operation.
SPECIFICATIONS
Power Input
9V DC – mains adaptor supplied
Power consumption
100mA, 2.1mm plug (centre positive)
MIDI
In, Out1 & Out2 (out1 & out2 give the same data out)
Inputs
16 GPI – 8 on each of 2 x 9 pin D connectors – pin 9 common ground
Display
3 x 7 segment display
Weight
850
gms
including
PSU
Dimensions
190 x 110 x 38 mm
Non-volatile memory
EEPROM (no back-up battery required)
WARRANTY
The
GPIM-16
comes with a 12 month (from purchase date) back to base warranty, (i.e. customer must
arrange and pay for carriage to and from Kenton Electronics).
Brookfarm House, 1 Station Road, South Wimbledon, London, SW19 2LP, UK
Tel: +44 (0)20 8544 9200 Fax: +44 (0)20 8544 9300
[email protected] www.kenton.co.uk
firmware rev# 1138 e. & o. e.