Kentech Instruments CPS3-S Notes On The Use Download Page 8

8

Kentech Instruments Ltd., Isis Building, Howbery Park, Wallingford, Oxfordshire, OX10 8BD, U.K.

Last Modified 11-2-20

3rd Angle

C  Kentech 2018

259

164

4

1.6

41.3

82.1

17.6

81.9

32.75

19.75

23.6

11.6

155

5.2

BS EN 22768 mK

1 of 

3

MATERIAL / SPEC

SURFACE TEXTURE

TOLERANCE

SHEET

REMOVE ALL BURRS

mm /  

A3

FINISH

QTY (PER SET)

DIMS / SCALE

PAPER

0030-0256 Special CPS3 for Lutronic Corp.

USED ON

ASM-0256-012-MAIN

  

TITLE

Kentech Instruments Ltd, Isis Building, Howbery Park, Wallingford, Oxfordshire, OX10 8BD, UK

MODIFICATION

DRAWN

DATE

REV

AKLDB

12-Jun-18

DRAWING NUMBER

ASM-0256-012-MAIN

screws not shown

1.000

SCALE  

1.000

SCALE  

1.000

SCALE  

7.2.3 

DIMENSIONS AND MOUNTING

There are four mount holes on the base plate, see below.

Summary of Contents for CPS3-S

Page 1: ...dule s n J19xxxxx Last Modified 11 2 20 PLEASE READ THIS MANUAL CAREFULLY BEFORE USING THE UNIT Kentech Instruments Ltd Isis Building Howbery Park Wallingford Oxfordshire OX10 8BD U K Tel 44 0 1491 82...

Page 2: ...2 20 Contents 1 DECLARATION OF CONFORMITY 3 2 DISCLAIMER 4 3 EMC CAUTION 4 4 ABBREVIATIONS 5 5 CAUTION 5 6 INTRODUCTION 5 7 OPERATION OF THE PULSER 6 7 1 GENERAL OPERATION 6 7 2 CONNECTIONS 6 7 2 1 F...

Page 3: ...3 23 EEC Low Voltage Directive 89 336 EEC Electromagnetic Compatibility Directive 93 68 EEC CE Marking Directive The following harmonised standards have been applied BSEN55011EmissionsSpecification Gr...

Page 4: ...her equipment in its immediate environment It is therefore suitable for use only in a laboratory or a sealed electromagnetic environment unless it is used in a system that has been verified by the sys...

Page 5: ...es incurred in the operation of this equipment Please read the manual before applying power 6 INTRODUCTION Our range of solid state pulsers ASG CPS HMPS and PBG series allows very high voltage fast ri...

Page 6: ...y should then be used If the unit is operated at less than about 11 9 volts the output amplitude may be reduced and the trigger delay increased Also note that the unit is fitted with a 13 volt zener d...

Page 7: ...FRONT PANEL CONNECTIONS This is an N type jack It is important to keep the insulator clean Light lubrication of the thread will stop metal particles from being generated 7 2 2 REAR PANEL CONNECTIONS...

Page 8: ...E TOLERANCE SHEET REMOVE ALL BURRS mm A3 FINISH QTY PER SET DIMS SCALE PAPER 0030 0256 Special CPS3 for Lutronic Corp USED ON ASM 0256 012 MAIN TITLE Kentech Instruments Ltd Isis Building Howbery Park...

Page 9: ...5 5 3 1 BS EN 22768 mK 2 of 3 MATERIAL SPEC SURFACE TEXTURE TOLERANCE SHEET REMOVE ALL BURRS mm A3 FINISH QTY PER SET DIMS SCALE PAPER USED ON ASM 0256 012 MAIN TITLE Kentech Instruments Ltd Isis Bui...

Page 10: ...s BNCtriggerinputtomainoutput Maximum repetition rate 30Hz Power supply 12 Volts DC 0 4 A Maximum power 7W Outputs Pulse output N type 3 6kV pulse Inputs Trigger input BNC jack 5V into 50 5ns rise tim...

Page 11: ...11 Kentech Instruments Ltd Isis Building Howbery Park Wallingford Oxfordshire OX10 8BD U K Last Modified 11 2 20 Figure 1 Pulse shape 4ns...

Page 12: ...12 Kentech Instruments Ltd Isis Building Howbery Park Wallingford Oxfordshire OX10 8BD U K Last Modified 11 2 20 Figure 2 Jitter 5ps SD...

Page 13: ...13 Kentech Instruments Ltd Isis Building Howbery Park Wallingford Oxfordshire OX10 8BD U K Last Modified 11 2 20 Figure 3 Trigger delay 19ns...

Reviews: