Summary of Contents for Wall Mountable Air Purifier

Page 1: ...ENT RO SYSTEMS LTD Unit 2 Khasra No 93 Village Bantakhedi Tehsil Roorkee District Haridwar Uttarakhand 247668 India Instruction Hand Book for Installation Operation and Maintenance Kent Ozone Air Purifier Wall Mountable D Lnk_Ranju_2012 Oct_2012 KENT_Oct_2012 Manual KENT Air Purifier Manual KENT Air Purifier Manual Size 5 5 8 25 dt 12 10 12 job no 644 ...

Page 2: ...e Air Purifier Read this manual carefully before using the product and keep it for future reference To enjoy the benefits of warranty fill up the enclosed warranty card and send the installation report within 15 days of purchase For further assistance contact your nearest KENT dealer or branch Best Wishes Kent RO Systems Ltd Table of Contents 1 Air Pollution An Evil Taxing the Modern Life 1 2 The ...

Page 3: ...the year 1865 In nature Ozone is formed because of the exogenic pressure of ultraviolet rays and atmospheric electrical discharges on dioxygen This powerful oxidant is abundantly present in the Earth s atmosphere The stratosphere at 10 to 50km altitude of the Earth s atmosphere holds the Ozone layer in low concentrations Here it absorbs 97 to 99 of the Sun s ultraviolet rays and prevents them from...

Page 4: ...ns Input 140 300 VAC Frequency 47 53Hz Output 12V DC 1000mA 9 6 Watts Caution Use only genuine Kent certified adaptor for the device If the adapter is damaged then purchase it from Kent or its authorised dealer Usage For removing the stale foul smells from a room use the device for at least 30 minutes Mount the device at a high place as Ozone is heavier than air Please set the operating function b...

Page 5: ...the Ozone Generator start their operations simultaneously For 1 minute the ozone generator produces ozone and the fan dissipates it In the 2nd minute the ozone generator stops functioning but the fan continues dissipation For the next 8 minutes both the ozone and the fan stop their operations and go into a dormant stage This process maintains the PPM level in a room The cycle repeats itself till t...

Page 6: ...n the device Do not forget to unplug the device while maintaining or cleaning it Keep the device out of the reach of children Consult your physician before trying any of the ozone therapy methods Troubleshooting NO 1 2 3 Reason Troubleshooting Replace the adaptor or remote when it is out of order Buy the adaptor or remote from Kent or its authorised distributor dealer only If the device is being u...