KENT Batch 9215 Instruction Manual Download Page 8

 

             High-pressure cleaners.       Batch - 92/9300 - ST 1500 

Date:     18/4-2017 

Instruction manual 

Page: 

8 of 36 

 Kent hojtryk\Clean-9200-9300-1500\Brugs-9200-6300-1500-EN-c.doc

 

 

Chemicals dosage: 

Fill plastic can with desired chemical. Mount injector suction hose in can. Open double nozzle pipe 
valve, and approx. 10 % chemical will be added to water. 
 
Indoor high-pressure cleaning is only permitted in halls and together with good ventilation. If you feel 
unwell during cleaning, stop working immediately and go outside. The reason may be the cleaning 
detergent which you may have used during cleaning. Thus, check carefully if these materials are being 
used in a safe and environmentally correct way. Information can often be found on the containers of the 
detergent. Never experiment with additives which can influence the health of the persons present and 
domestic animals, if any. In case of contact with eyes, rinse immediately with plenty of water and seek 
medical advice. Show the label of the cleaning detergent where possible, e.g. bring the container in 
order to obtain the best medical treatment. 
 
The quality of cleaning detergents may vary and you must make sure they are suitable for high opera-
ting temperatures under high pressure. Consider the environment in particular where there is run-off to 
unprotected drainage. Obtain data sheets, if necessary, with definition of class of danger of the substan-
ce and personal protection on a scale of 1 to 6 where 6 is the most hazardous! Never use aggressive 
substances such as acids, solvents or explosive substances together with this unit. Use a less corrosive 
cleaning detergent, if possible. 
 

Start-up of machine:

 

1.  Now you can turn on the water. 
2.  Hold the gun in open position for venting. 
3.   Switch the machine on. 
4.   The pressure can be adjusted on the double nozzle pipe. 
 
 

Respiratory protection equipment / hearing protection (Danish At-instruction (At = Danish Working 
Environment Authority) D. 2.20 November 2006): 

Employees must wear suitable respiratory protection 

equipment during work under 2.5 MPa (25 bar) if aggravating factors such as chemicals harmful to health by 
inhalation, micro-organisms or organic origin residue are present. 
 
Always wear suitable respiratory protection equipment during work over 2.5 MPa (25 bar). 
 
The respiratory protection equipment must contain at least a P2 filter protecting against both solid particles and 
liquid aerosols.  The safest method is to use self-contained respiratory protection equipment. There can often be 
doubt about the nature and concentration of the air pollution as it is difficult to determine what will detach from the 
sprayed surfaces. If work is carried out for more than three hours on a daily basis the respiratory protection 
equipment must be self-contained or filtering by turbo-unit (blower). 
 
Inhalation of aerosols with surfactants (e.g. soap) and fat and protein residue constitutes a risk of developing 
respiratory disease and is also mucous membrane irritant (3). 

 

Summary of Contents for Batch 9215

Page 1: ...1 Preparation Page 6 2 2 Start up Page 7 2 3 Safety rules Page 12 3 Maintenance instructions Page 14 3 1 General maintenance Page 14 3 2 Fault finding Page 16 3 3 Spare parts Page 17 4 Installation a...

Page 2: ...e sikkerheds og sundhedskrav i forbindelse med konstruktion og fremstilling af maskiner Bestemmelserne i R dets direktiv af 12 december 2006 om indbyrdes tiln rmelse af medlemstat ernes lovgivning om...

Page 3: ...ctive on essential safety and health requirements in relation to construction and manufacture of machines Provision in the Council Directive of 12 December 2006 on mutual approximation of the laws of...

Page 4: ...x 230 volt or 3 x 400 volt Please see the nameplate The high pressure cleaner must only be used with process water or collected rain water with a purity equal to tap water The water supply must be eq...

Page 5: ...al designs and only pump electric motor and some components may vary depending on the model See Technical specifications Product range Pump 3 cylinder vibrationless and noiseless oil bath lubricated h...

Page 6: ...ork or take appropriate breaks in order to avoid monotonous strain Check oil level through pump indicator glass Change oil after 25 hours of operation Then after each 200 hours of operation Use a good...

Page 7: ...vel Connection of the high pressure hose and lance 1 Connect one end of the high pressure hose to the gun the other end has to be connected to the outlet of the pump After that mount the lance to the...

Page 8: ...f the substan ce and personal protection on a scale of 1 to 6 where 6 is the most hazardous Never use aggressive substances such as acids solvents or explosive substances together with this unit Use a...

Page 9: ...ssary to wear personal protection equipment even after the actual pressure work has stopped Very small aerosols may stay in the air for up to 1 5 hours Class P2 has a better elimination degree and the...

Page 10: ...cord check that the connection is water tight Keep all connections off the ground to avoid possible contacts with water 5 Do not pull power cord to unplug 6 While the machine is running do not cover i...

Page 11: ...ose and injector non return valve MUST be cleaned with pure water Place injector suction hose in a bucket or similar container with pure water and allow injector to suck water for a few minutes Never...

Page 12: ...lable for all persons using the device 5 The high pressure cleaner must not be used if the safety devices are defective All electrical connections must be waterproof 6 High pressure hoses and lance mu...

Page 13: ...chine on a frost free location If this is not possible you must frost proof the machine as described in the following section 15 High pressure cleaning in freezing weather requires immediate start up...

Page 14: ...r water leakage during start up Check if pump is noisy Every year Inspection of frame and lifting brackets visual inspection for cracks and loose bolts Test of flow meter Thread connection at input st...

Page 15: ...carry out a correct repair prior to using the high pressure cleaner again Disposal of machine If you decide not to use the machine any longer we recommend that you make the machine unusable by removi...

Page 16: ...X see spare parts drawing Check flow through hose gun and nozzle pipes Injector cannot suck chemicals Non return valve gone slack sucks dead air Retighten replaces nylon gasket Ball hangs old soap res...

Page 17: ...1500 Brugs 9200 6300 1500 EN c doc 3 3 Spare parts Note model number and name plate on the high pressure cleaner so that we can deliver the ordered spare parts to your machine Always use original spa...

Page 18: ...High pressure cleaners Batch 92 9300 ST 1500 Date 18 4 2017 Instruction manual Page 18 of 36 Kent hojtryk Clean 9200 9300 1500 Brugs 9200 6300 1500 EN c doc Spare parts drawing for Batch 92 9300...

Page 19: ...gh pressure cleaners Batch 92 9300 ST 1500 Date 18 4 2017 Instruction manual Page 19 of 36 Kent hojtryk Clean 9200 9300 1500 Brugs 9200 6300 1500 EN c doc Spare parts drawing for ST 1521 ST 1525 ST 15...

Page 20: ...Justeringsskrue Pinolskrue Glideskive M trik Fjeder Hylse Ventilhus Cylinder stift Reparations KIT Afstandshylse Muffe O ring KIT A Ventildel KIT A Fjeder KIT A Ventilhus KIT A Sikringsm rtik O ring I...

Page 21: ...High pressure cleaners Batch 92 9300 ST 1500 Date 18 4 2017 Instruction manual Page 21 of 36 Kent hojtryk Clean 9200 9300 1500 Brugs 9200 6300 1500 EN c doc Unloader ST 280...

Page 22: ...High pressure cleaners Batch 92 9300 ST 1500 Date 18 4 2017 Instruction manual Page 22 of 36 Kent hojtryk Clean 9200 9300 1500 Brugs 9200 6300 1500 EN c doc Unloader VB85...

Page 23: ...High pressure cleaners Batch 92 9300 ST 1500 Date 18 4 2017 Instruction manual Page 23 of 36 Kent hojtryk Clean 9200 9300 1500 Brugs 9200 6300 1500 EN c doc 9315 9315...

Page 24: ...High pressure cleaners Batch 92 9300 ST 1500 Date 18 4 2017 Instruction manual Page 24 of 36 Kent hojtryk Clean 9200 9300 1500 Brugs 9200 6300 1500 EN c doc 9215 9221 ST 1521...

Page 25: ...High pressure cleaners Batch 92 9300 ST 1500 Date 18 4 2017 Instruction manual Page 25 of 36 Kent hojtryk Clean 9200 9300 1500 Brugs 9200 6300 1500 EN c doc 9225 ST 1525...

Page 26: ...High pressure cleaners Batch 92 9300 ST 1500 Date 18 4 2017 Instruction manual Page 26 of 36 Kent hojtryk Clean 9200 9300 1500 Brugs 9200 6300 1500 EN c doc 9230 ST 1519...

Page 27: ...High pressure cleaners Batch 92 9300 ST 1500 Date 18 4 2017 Instruction manual Page 27 of 36 Kent hojtryk Clean 9200 9300 1500 Brugs 9200 6300 1500 EN c doc 9330 9336 9342...

Page 28: ...High pressure cleaners Batch 92 9300 ST 1500 Date 18 4 2017 Instruction manual Page 28 of 36 Kent hojtryk Clean 9200 9300 1500 Brugs 9200 6300 1500 EN c doc 9350...

Page 29: ...he components of the packaging bag boxes components for fastening are placed out of the reach of children Identifikation Label Before using the machine make sure that it is provided with the identific...

Page 30: ...580 510 105 9336 170 2500 36 3 11 15 3x230 400 700 580 510 105 9342 150 2200 42 3 11 15 3x230 400 700 580 510 105 9350 100 1700 50 3 11 15 3x230 400 700 580 510 105 ST 1521 200 2900 21 3 7 5 10 3x230...

Page 31: ...truction manual Page 31 of 36 Kent hojtryk Clean 9200 9300 1500 Brugs 9200 6300 1500 EN c doc 4 4 Eldiagram 7 5 kW 11 kW 058053 058064 30A 230V 45A 230V 25A 400V 30A 400V 056184 056182 056181 056183 3...

Page 32: ...High pressure cleaners Batch 92 9300 ST 1500 Date 18 4 2017 Instruction manual Page 32 of 36 Kent hojtryk Clean 9200 9300 1500 Brugs 9200 6300 1500 EN c doc...

Page 33: ...High pressure cleaners Batch 92 9300 ST 1500 Date 18 4 2017 Instruction manual Page 33 of 36 Kent hojtryk Clean 9200 9300 1500 Brugs 9200 6300 1500 EN c doc 5 Notes...

Page 34: ...High pressure cleaners Batch 92 9300 ST 1500 Date 18 4 2017 Instruction manual Page 34 of 36 Kent hojtryk Clean 9200 9300 1500 Brugs 9200 6300 1500 EN c doc...

Page 35: ...9300 ST 1500 Date 18 4 2017 Instruction manual Page 35 of 36 Kent hojtryk Clean 9200 9300 1500 Brugs 9200 6300 1500 EN c doc KENT H JTRYK A S SKOVBRYNET 10 DK 6752 GLEJBJERG TLF 45 75 19 80 33 www ke...

Page 36: ...200 9300 1500 Brugs 9200 6300 1500 EN c doc Hot water cleaners up to 30 l min and 500 bars with gasoline diesel electric motor oil heated And low pressure Hot Box with max flow 45 l min Hotbox with an...