background image

9.USB firmware upgrade

When firmware update, repair or function change, support for program updates,

provides front panel USB port upgrade, upgrading the system program through the front

panel "firmware" port, the latest upgrade program can contact our company technical and

sales personnel.

The upgrade steps are as follows:

1. Download the upgrade software to your computer;

2. Connect the front panel "FIRMWARE" interface to the computer's USB interface with

Micro USB Micro line;

3.Run the upgraded software, double click the software icon, as shown below:

Fig 9.1 Upgrade software

4 Open the upgrade software to enter the following interface;

Fig 9.2 Upgrade software interface

Click "Connect USB" connect computer to the host;

Click "Open", choose to download the upgrade file;

Click "Updata", the system began to upgrade.

After the completion of the upgrade, pop-up "Updata success " dialog box, the program

upgrade successfully.

Summary of Contents for FMX Series

Page 1: ...1 FMX Flexible Matrix Switcher Operation manual Kensence Shenzhen Technology Development CO LTD Version V1 01 01 2016 4...

Page 2: ...n 2 5 Specification 3 6 Device panel description 4 7 Card introduction 6 8 Matrix control operation introduction 13 8 1Panel control 13 8 2 RS232 Control 14 8 3 TCP IP communication port control 22 9...

Page 3: ...ll the plug before moving the device or doing some specific works witch need to be done when the electricity is turned off Please turn off the main power switch on rainy days or when not in use for a...

Page 4: ...Do not sprinkle any corrosive chemicals or liquid on or around the device To avoid accident or any further damage non professionals please do not dismantle or maintain the device without permission D...

Page 5: ...used in government judicial military education medical business and other occasions 2 Features Modular design support HDMI DVI SDI HDBT HDCI signal card VGA Audio cards and can be free to match impro...

Page 6: ...g in and out of the card please be careful to operate in case of damaging the circuit when the matrix is power on 2 Connect the output port to HD display such as HDTV or HD projector 3 Firstly power o...

Page 7: ...roduct Please contact us if the product is faulted or not intact We will sincerely serve you according to relevant provisions NO Name Quantity Unit 1 Matrix Host 1 pcs 2 Dryer 50g 1 pcs 3 AC power ada...

Page 8: ...col RS232 baud rate 115200 data bits 8 stop bit 1 no parity Connector 9 pin D sub DE9F jack2 TX 3 RX 5 GND Network IP Control protocol TCP IP Connector RJ45 connector 10 100 Base T Ethernet Color spac...

Page 9: ...Serial port Control protocol RS232 baud rate 115200 data bits 8 stop bit 1 no parity Network IP Control protocol TCP IP Connector RJ45 connector 10 100 Base T Ethernet Color space Supports RGB444 YUV4...

Page 10: ...terface to upgrade the firmware 2 Power indicator when switch on it s always bright 3 LCD screen display real time operating status 4 INPUT and OUTPUT Key area 5 function key area including ALL select...

Page 11: ...3 Infrared signal input port connected with carrier infrared receiver the received infrared signal simultaneously transmitted to the remote receiver through the twisted pair to achieve multi broadcas...

Page 12: ...6 75 Gbps The output resolution of the output card can be adjusted 1360x768 60Hz 1024x768 60Hz 1280x720 60Hz 1280x800 60Hz 1920x1080 60Hz default 1920x1200 60Hz 1600x1200 60Hz Compatible with EDID Si...

Page 13: ...Data 2 Shield 19 Hot Plug Detect 3 TMDS Data 2 18 5V Power 4 TMDS Data 1 17 Ground 5 TMDS Data 1 Shield 16 DDC Data 6 TMDS Data 1 15 DDC Clock 7 TMDS Data 0 14 No Connect 8 TMDS Data 0 Shield 13 CEC 9...

Page 14: ...signal format can be set through the serial port The output resolution of the output card can be adjusted 1280x720P 60Hz 1920x1080 60Hz default 800x600 60Hz 1024x768 60Hz 1280x1024 60Hz 1920x1200 60H...

Page 15: ...2 T M D S Clock Shield 11 T M D S Data1 3 Shield 23 T M D S Clock 12 T M D S Data3 24 T M D S Clock C1 Analog Red C2 Analog Green C3 Analog Blue C4 Horizontal Sync Analog C5 Analog Ground analog R G B...

Page 16: ...DVI to C VIDEO Pin Signal name C1 YELLOW C5 GND The remaining pins are empty...

Page 17: ...nd output card FMX HDBT IN FMX HDBT OUT Accord with HDBT1 0 standards compatible with HDCP1 4 EDID DVI I Pin VGA Pin Signal name DVI I Pin VGA Pin Signal name 8 14 HSync C4 13 VSync C1 1 RED C5 6 GND...

Page 18: ...al port coordinate with remote transmitter receiver serial port to achieve two way communication Audio input port can be select by serial command AUDIO X I Z choosing embedded audio or non balance ext...

Page 19: ...Green and white 1 Orange and white 2 Green 2 Orange 3 Orange and white 3 Green and white 4 Blue 4 Blue 5 Blue and white 5 Blue and white 6 Orange 6 Green 7 Brown and white 7 Brown and white 8 Brown 8...

Page 20: ...DI 3G SDI signal Input resolution can be automatic recognition Upscaling function the low input resolution was upscaled to 1080P output by default Output resolution of each output card can be adjusted...

Page 21: ...matrix host Output card connect to Polycom conference terminal such as HXD 7000 HD Compatible with YPbPr maximum resolution support 1080P FMX HDCI IN FMX HDCI OUT HDCI 60P parent pin description Signa...

Page 22: ...imes and then press 1 and 3 in the output port area and then press ENTER If you want to switch one way to all the output ports you can use the ALL button Example 3 input port 3 switch to all output po...

Page 23: ...Here take SSCOM32 as an example to explain Software installation method copy control software to normal connection control device Software uninstall method delete the overall folder where the control...

Page 24: ...ation protocol baud rate 9600 data bits 8 stop bit 1 no parity bit RS232 Command Function description Return code Control host command Type Query matrix model MODULAR3232 N Lock Lock the front panel b...

Page 25: ...1 1 32 32 All Through x The channel x input switch to the channel x output audio and video 01 Through All Turn off all output channels audio and video All Closed x Close channel x output audio and vid...

Page 26: ...01 A 01 001 Clear Y Clear the stored unit Y data and the status is all closed Clear F8 PWON regular work PWON PWOFF Standby PWOFF HDCPON Opening the HDCP protocol in output channel HDCPON HDCPOFF Clos...

Page 27: ...DIDG x Get the output port EDID data and display x output port number through serial port EDIDM X B Y Copy X the monitor EDID of output port to Y input port if error will be initialized by the EDID da...

Page 28: ...resolution 1280x720 60Hz 0627 USER I x 0628 VGA DVI HDMI SDI input card set input channel x resolution 1280x800 60Hz 0628 USER I x 0629 VGA DVI HDMI SDI input card set input channel x resolution 1920x...

Page 29: ...VI HDMI SDI input card set the input channel x image proportion 0608 USER I x 0614 DVI HDMI SDI input card set the input channel x signal to P P image mode cycle switch to different image mode 0614 US...

Page 30: ...110 USER O x 0111 HDMI output card close output channel x analog audio 0111 GetResolution x DVI HDMI output card access to the resolution of output channel x GetVGAPortMode x DVI HDMI output card quer...

Page 31: ...TCP IP communication port control matrix its factory default IP address is 192 168 10 2 gateway 192 168 0 1 IP gateway can be changed port number 4001 no change The matrix host can be connected to a s...

Page 32: ...ct matrix host to a computer with same IP through twisted pair open browser enter the default IP 192 168 10 2 IP is changeable for example matrix host IP change to 192 168 0 112 Here input IP 192 168...

Page 33: ...ple to set the 27 output card resolution click on drop down arrow of channel 27 card select the appropriate resolution is ok Output card signal output mode change Enter the GUI main interface select S...

Page 34: ...5 first select the input port for example select input 3 and then select the output port such as select output 1 and 5 and click OK button then the input end 3 signal is switched to the output termin...

Page 35: ...xample select the number 5 click on the save the current configuration state of the matrix is saved to scene 5 When calling scene in Scene select the scene to call and then click call can be Fig 8 3 6...

Page 36: ...n click Save can be ok Fig8 3 7 User interface Input output port name change Click the interface option pop up as shown in figure 8 3 8 interface double click the name you want to change of the input...

Page 37: ...T card Fig 8 3 9 HDCP compatible setting interface EDID learning function Click EDID option pop up as shown in figure 8 3 10 interface can choose 1 to 1 EDID learning or all input side of the single o...

Page 38: ...pop up as shown in figure 8 3 11 interface select DHCP or Static IP option and then enter the changed IP address click save DHCP is LAN control mode the use of LAN can control a number of matrix figur...

Page 39: ...Fig 8 3 12 LAN control diagram...

Page 40: ...o your computer 2 Connect the front panel FIRMWARE interface to the computer s USB interface with Micro USB Micro line 3 Run the upgraded software double click the software icon as shown below Fig 9 1...

Page 41: ...al display device image has shadow Input and output connection wire quality is not up to standard or damage Replace normal standard wire Bad connection between input and output devices Check connectio...

Page 42: ...machine Control terminal communication port damage Carefully check whether the communication serial port loose or damaged Communication protocol is not set Check as follows baud rate 9600 data bits 8...

Page 43: ...ge caused to the configuration or modification of the product without the authorization of our company The damage caused by the force majeure 4 Any of the following circumstances the company has the r...

Page 44: ...s Kensence Shenzhen Technology Development CO LTD Address 19F Building A NO 196 Tangtou blvd Shixin community Shiyan Town Baoan District Shenzhen China 518108 Fax 86 0755 29459442 Website http www ken...

Reviews: